Cargando…

Hemodynamic behavior of stentless aortic valves in long term follow-up

OBJECTIVES: Stentless aortic valve replacements show improved hemodynamics due to larger orifice area and lower transvalvular gradients in short and mid-term follow-up. Hemodynamic long-term behavior and the adaptation of the left ventricle as well as valve-durability in patients aged ≤60 years rema...

Descripción completa

Detalles Bibliográficos
Autores principales: Christ, Torsten, Grubitzsch, Herko, Claus, Benjamin, Heinze, Georg, Dushe, Simon, Konertz, Wolfgang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4297443/
https://www.ncbi.nlm.nih.gov/pubmed/25527116
http://dx.doi.org/10.1186/s13019-014-0197-2
_version_ 1782353152882769920
author Christ, Torsten
Grubitzsch, Herko
Claus, Benjamin
Heinze, Georg
Dushe, Simon
Konertz, Wolfgang
author_facet Christ, Torsten
Grubitzsch, Herko
Claus, Benjamin
Heinze, Georg
Dushe, Simon
Konertz, Wolfgang
author_sort Christ, Torsten
collection PubMed
description OBJECTIVES: Stentless aortic valve replacements show improved hemodynamics due to larger orifice area and lower transvalvular gradients in short and mid-term follow-up. Hemodynamic long-term behavior and the adaptation of the left ventricle as well as valve-durability in patients aged ≤60 years remains unclear. METHODS: 7 to 16 years after aortic valve replacement, 54 patients (mean age at operation 53.1 ± years) received echocardiography and clinical examination. Mean follow-up time was 10.8 ± 2.2 years. Evaluated were NYHA class, transvalvular gradients, estimated aortic valve orifice area, degree of aortic valve insufficiency, left ventricular mass and function. RESULTS: At follow-up only one patient presented with NYHA class III. All other patients were in NYHA class I or II. Maximum and mean pressure gradients of the prostheses were 16.3 ± 7.4 mmHg and 9.1 ± 4.2 mmHg, respectively. Compared to echocardiography at discharge the mean pressure gradients dropped 18.0% (2.0 ± 0.9 mmHg) and stayed stable until 14 years after the operation. Only 5 patients showed relevant regurgitation (at 13–16 years after valve replacement), 49 showed no or trivial regurgitation. Left ventricular mass had decreased 26.5% (107.9 ± 18.5 g). Left ventricular ejection fraction (LVEF) had increased in most patients and decreased in only one. For patients with preoperatively impaired left ventricular function an increase of LVEF of 13.1 ± 3.1% was seen. CONCLUSION: Porcine stentless aortic valves provide excellent hemodynamic long-term results without significant rise of transvalvular pressure gradients or relevant insufficiencies until 14 years after implantation, leading to sustained decrease of left ventricular mass and improvement of left ventricular function. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13019-014-0197-2) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4297443
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42974432015-01-18 Hemodynamic behavior of stentless aortic valves in long term follow-up Christ, Torsten Grubitzsch, Herko Claus, Benjamin Heinze, Georg Dushe, Simon Konertz, Wolfgang J Cardiothorac Surg Research Article OBJECTIVES: Stentless aortic valve replacements show improved hemodynamics due to larger orifice area and lower transvalvular gradients in short and mid-term follow-up. Hemodynamic long-term behavior and the adaptation of the left ventricle as well as valve-durability in patients aged ≤60 years remains unclear. METHODS: 7 to 16 years after aortic valve replacement, 54 patients (mean age at operation 53.1 ± years) received echocardiography and clinical examination. Mean follow-up time was 10.8 ± 2.2 years. Evaluated were NYHA class, transvalvular gradients, estimated aortic valve orifice area, degree of aortic valve insufficiency, left ventricular mass and function. RESULTS: At follow-up only one patient presented with NYHA class III. All other patients were in NYHA class I or II. Maximum and mean pressure gradients of the prostheses were 16.3 ± 7.4 mmHg and 9.1 ± 4.2 mmHg, respectively. Compared to echocardiography at discharge the mean pressure gradients dropped 18.0% (2.0 ± 0.9 mmHg) and stayed stable until 14 years after the operation. Only 5 patients showed relevant regurgitation (at 13–16 years after valve replacement), 49 showed no or trivial regurgitation. Left ventricular mass had decreased 26.5% (107.9 ± 18.5 g). Left ventricular ejection fraction (LVEF) had increased in most patients and decreased in only one. For patients with preoperatively impaired left ventricular function an increase of LVEF of 13.1 ± 3.1% was seen. CONCLUSION: Porcine stentless aortic valves provide excellent hemodynamic long-term results without significant rise of transvalvular pressure gradients or relevant insufficiencies until 14 years after implantation, leading to sustained decrease of left ventricular mass and improvement of left ventricular function. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13019-014-0197-2) contains supplementary material, which is available to authorized users. BioMed Central 2014-12-20 /pmc/articles/PMC4297443/ /pubmed/25527116 http://dx.doi.org/10.1186/s13019-014-0197-2 Text en © Christ et al.; licensee BioMed Central. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Christ, Torsten
Grubitzsch, Herko
Claus, Benjamin
Heinze, Georg
Dushe, Simon
Konertz, Wolfgang
Hemodynamic behavior of stentless aortic valves in long term follow-up
title Hemodynamic behavior of stentless aortic valves in long term follow-up
title_full Hemodynamic behavior of stentless aortic valves in long term follow-up
title_fullStr Hemodynamic behavior of stentless aortic valves in long term follow-up
title_full_unstemmed Hemodynamic behavior of stentless aortic valves in long term follow-up
title_short Hemodynamic behavior of stentless aortic valves in long term follow-up
title_sort hemodynamic behavior of stentless aortic valves in long term follow-up
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4297443/
https://www.ncbi.nlm.nih.gov/pubmed/25527116
http://dx.doi.org/10.1186/s13019-014-0197-2
work_keys_str_mv AT christtorsten hemodynamicbehaviorofstentlessaorticvalvesinlongtermfollowup
AT grubitzschherko hemodynamicbehaviorofstentlessaorticvalvesinlongtermfollowup
AT clausbenjamin hemodynamicbehaviorofstentlessaorticvalvesinlongtermfollowup
AT heinzegeorg hemodynamicbehaviorofstentlessaorticvalvesinlongtermfollowup
AT dushesimon hemodynamicbehaviorofstentlessaorticvalvesinlongtermfollowup
AT konertzwolfgang hemodynamicbehaviorofstentlessaorticvalvesinlongtermfollowup