Cargando…

Pullout of a lumbar plate with varying screw lengths

BACKGROUND: Screw length pertains to stability in various orthopedic fixation devices. There is little or no information on the relationship between plate pullout strength and screw length in anterior lumbar interbody fusion (ALIF) plate constructs in the literature. Such a description may prove use...

Descripción completa

Detalles Bibliográficos
Autores principales: Palmer, Daniel Kyle, Rios, David, Patacxil, Wyzscx Merfil, Williams, Paul A., Cheng, Wayne K., İnceoğlu, Serkan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Society for the Advancement of Spine Surgery 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4300880/
https://www.ncbi.nlm.nih.gov/pubmed/25694864
http://dx.doi.org/10.1016/j.ijsp.2011.12.002
_version_ 1782353579917443072
author Palmer, Daniel Kyle
Rios, David
Patacxil, Wyzscx Merfil
Williams, Paul A.
Cheng, Wayne K.
İnceoğlu, Serkan
author_facet Palmer, Daniel Kyle
Rios, David
Patacxil, Wyzscx Merfil
Williams, Paul A.
Cheng, Wayne K.
İnceoğlu, Serkan
author_sort Palmer, Daniel Kyle
collection PubMed
description BACKGROUND: Screw length pertains to stability in various orthopedic fixation devices. There is little or no information on the relationship between plate pullout strength and screw length in anterior lumbar interbody fusion (ALIF) plate constructs in the literature. Such a description may prove useful, especially in the treatment of osteoporotic patients where maximizing construct stability is of utmost importance. Our purpose is to describe the influence of screw length on ALIF plate stability in severely and mildly osteoporotic bone foam models. METHODS: Testing was performed on polyurethane foam blocks with densities of 0.08 g/cm(3) and 0.16 g/cm(3). Four-screw, single-level ALIF plate constructs were secured to the polyurethane foam blocks by use of sets of self-tapping cancellous bone screws that were 20, 24, 28, 32, and 36 mm in length and 6.0 mm in diameter. Plates were pulled out at 1 mm/min to failure, as defined by consistently decreasing load despite increasing displacement. RESULTS: Pullout loads in 0.08-g/cm(3) foam for 20-, 24-, 28-, 32-, and 36-mm screws averaged 303, 388, 479, 586, and 708 N, respectively, increasing at a mean of 25.2 N/mm. In 0.16-g/cm(3) foam, pullout loads for 20-, 24-, 28-, 32-, and 36-mm screws averaged 1004, 1335, 1569, 1907, and 2162 N, respectively, increasing at a mean of 72.2 N/mm. CONCLUSIONS: The use of longer screws in ALIF plate installation is expected to increase construct stability. Stabilization from screw length in osteoporotic patients, however, is limited.
format Online
Article
Text
id pubmed-4300880
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher International Society for the Advancement of Spine Surgery
record_format MEDLINE/PubMed
spelling pubmed-43008802015-02-18 Pullout of a lumbar plate with varying screw lengths Palmer, Daniel Kyle Rios, David Patacxil, Wyzscx Merfil Williams, Paul A. Cheng, Wayne K. İnceoğlu, Serkan Int J Spine Surg Full Length Article BACKGROUND: Screw length pertains to stability in various orthopedic fixation devices. There is little or no information on the relationship between plate pullout strength and screw length in anterior lumbar interbody fusion (ALIF) plate constructs in the literature. Such a description may prove useful, especially in the treatment of osteoporotic patients where maximizing construct stability is of utmost importance. Our purpose is to describe the influence of screw length on ALIF plate stability in severely and mildly osteoporotic bone foam models. METHODS: Testing was performed on polyurethane foam blocks with densities of 0.08 g/cm(3) and 0.16 g/cm(3). Four-screw, single-level ALIF plate constructs were secured to the polyurethane foam blocks by use of sets of self-tapping cancellous bone screws that were 20, 24, 28, 32, and 36 mm in length and 6.0 mm in diameter. Plates were pulled out at 1 mm/min to failure, as defined by consistently decreasing load despite increasing displacement. RESULTS: Pullout loads in 0.08-g/cm(3) foam for 20-, 24-, 28-, 32-, and 36-mm screws averaged 303, 388, 479, 586, and 708 N, respectively, increasing at a mean of 25.2 N/mm. In 0.16-g/cm(3) foam, pullout loads for 20-, 24-, 28-, 32-, and 36-mm screws averaged 1004, 1335, 1569, 1907, and 2162 N, respectively, increasing at a mean of 72.2 N/mm. CONCLUSIONS: The use of longer screws in ALIF plate installation is expected to increase construct stability. Stabilization from screw length in osteoporotic patients, however, is limited. International Society for the Advancement of Spine Surgery 2012-12-01 /pmc/articles/PMC4300880/ /pubmed/25694864 http://dx.doi.org/10.1016/j.ijsp.2011.12.002 Text en © 2012 ISASS - International Society for the Advancement of Spine Surgery. Published by Elsevier Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Length Article
Palmer, Daniel Kyle
Rios, David
Patacxil, Wyzscx Merfil
Williams, Paul A.
Cheng, Wayne K.
İnceoğlu, Serkan
Pullout of a lumbar plate with varying screw lengths
title Pullout of a lumbar plate with varying screw lengths
title_full Pullout of a lumbar plate with varying screw lengths
title_fullStr Pullout of a lumbar plate with varying screw lengths
title_full_unstemmed Pullout of a lumbar plate with varying screw lengths
title_short Pullout of a lumbar plate with varying screw lengths
title_sort pullout of a lumbar plate with varying screw lengths
topic Full Length Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4300880/
https://www.ncbi.nlm.nih.gov/pubmed/25694864
http://dx.doi.org/10.1016/j.ijsp.2011.12.002
work_keys_str_mv AT palmerdanielkyle pulloutofalumbarplatewithvaryingscrewlengths
AT riosdavid pulloutofalumbarplatewithvaryingscrewlengths
AT patacxilwyzscxmerfil pulloutofalumbarplatewithvaryingscrewlengths
AT williamspaula pulloutofalumbarplatewithvaryingscrewlengths
AT chengwaynek pulloutofalumbarplatewithvaryingscrewlengths
AT inceogluserkan pulloutofalumbarplatewithvaryingscrewlengths