Biomechanical assessment and fatigue characteristics of an articulating nucleus implant

BACKGROUND: Extrusion is a known complication of lumbar nucleus replacement devices. Despite this fact, this complication has not been well studied in an in vitro cadaveric model under fatigue-loading conditions. METHODS: Lumbar constructs (with treated and control levels) were tested in intact, pos...

Descripción completa

Detalles Bibliográficos
Autores principales: Ordway, Nathaniel R., Lavelle, William F., Brown, Tim, Bao, Q-Bin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier, Inc. 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4300979/
https://www.ncbi.nlm.nih.gov/pubmed/25694897
http://dx.doi.org/10.1016/j.ijsp.2013.10.001
_version_ 1782353593037225984
author Ordway, Nathaniel R.
Lavelle, William F.
Brown, Tim
Bao, Q-Bin
author_facet Ordway, Nathaniel R.
Lavelle, William F.
Brown, Tim
Bao, Q-Bin
author_sort Ordway, Nathaniel R.
collection PubMed
description BACKGROUND: Extrusion is a known complication of lumbar nucleus replacement devices. Despite this fact, this complication has not been well studied in an in vitro cadaveric model under fatigue-loading conditions. METHODS: Lumbar constructs (with treated and control levels) were tested in intact, postdisectomy, and postnucleus implant conditions under compression, torsion, and bending for initial biomechanical assessment. Constructs were then tested for 100(k) cycles under fatigue loading to assess extrusion risk. Potential adverse effects to vertebral and endplate fractures were assessed using gross dissection and macroscopic and micro-computed tomography evaluation techniques. RESULTS: Based on the initial biomechanical assessment, implantation of the nucleus device significantly increased disc height compared with the discectomy condition, and there were no significant differences between the intact and implanted conditions for range of motion or stiffness. All constructs completed the 100(k) cycles with no extrusions. There was evidence of implant shift toward the right lateral annulus on postfatigue images. Postfatigue dissection and imaging showed no evidence of macroscopic endplate or trabecular fractures. CONCLUSION: Using a 2-level lumbar in vitro construct, the biomechanical function of the treated level with an articulating nucleus implant was similar to intact. In vitro fatigue testing showed no implant extrusion and macroscopic changes to the bony structure or cartilaginous endplates when comparing treated and intact levels.
format Online
Article
Text
id pubmed-4300979
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Elsevier, Inc.
record_format MEDLINE/PubMed
spelling pubmed-43009792015-02-18 Biomechanical assessment and fatigue characteristics of an articulating nucleus implant Ordway, Nathaniel R. Lavelle, William F. Brown, Tim Bao, Q-Bin Int J Spine Surg Full Length Article BACKGROUND: Extrusion is a known complication of lumbar nucleus replacement devices. Despite this fact, this complication has not been well studied in an in vitro cadaveric model under fatigue-loading conditions. METHODS: Lumbar constructs (with treated and control levels) were tested in intact, postdisectomy, and postnucleus implant conditions under compression, torsion, and bending for initial biomechanical assessment. Constructs were then tested for 100(k) cycles under fatigue loading to assess extrusion risk. Potential adverse effects to vertebral and endplate fractures were assessed using gross dissection and macroscopic and micro-computed tomography evaluation techniques. RESULTS: Based on the initial biomechanical assessment, implantation of the nucleus device significantly increased disc height compared with the discectomy condition, and there were no significant differences between the intact and implanted conditions for range of motion or stiffness. All constructs completed the 100(k) cycles with no extrusions. There was evidence of implant shift toward the right lateral annulus on postfatigue images. Postfatigue dissection and imaging showed no evidence of macroscopic endplate or trabecular fractures. CONCLUSION: Using a 2-level lumbar in vitro construct, the biomechanical function of the treated level with an articulating nucleus implant was similar to intact. In vitro fatigue testing showed no implant extrusion and macroscopic changes to the bony structure or cartilaginous endplates when comparing treated and intact levels. Elsevier, Inc. 2013-12-01 /pmc/articles/PMC4300979/ /pubmed/25694897 http://dx.doi.org/10.1016/j.ijsp.2013.10.001 Text en © 2013 ISASS - The International Society for the Advancement of Spine Surgery. Published by Elsevier Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Length Article
Ordway, Nathaniel R.
Lavelle, William F.
Brown, Tim
Bao, Q-Bin
Biomechanical assessment and fatigue characteristics of an articulating nucleus implant
title Biomechanical assessment and fatigue characteristics of an articulating nucleus implant
title_full Biomechanical assessment and fatigue characteristics of an articulating nucleus implant
title_fullStr Biomechanical assessment and fatigue characteristics of an articulating nucleus implant
title_full_unstemmed Biomechanical assessment and fatigue characteristics of an articulating nucleus implant
title_short Biomechanical assessment and fatigue characteristics of an articulating nucleus implant
title_sort biomechanical assessment and fatigue characteristics of an articulating nucleus implant
topic Full Length Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4300979/
https://www.ncbi.nlm.nih.gov/pubmed/25694897
http://dx.doi.org/10.1016/j.ijsp.2013.10.001
work_keys_str_mv AT ordwaynathanielr biomechanicalassessmentandfatiguecharacteristicsofanarticulatingnucleusimplant
AT lavellewilliamf biomechanicalassessmentandfatiguecharacteristicsofanarticulatingnucleusimplant
AT browntim biomechanicalassessmentandfatiguecharacteristicsofanarticulatingnucleusimplant
AT baoqbin biomechanicalassessmentandfatiguecharacteristicsofanarticulatingnucleusimplant