Cargando…

Effects on inadvertent endplate fracture following lateral cage placement on range of motion and indirect spine decompression in lumbar spine fusion constructs: A cadaveric study

BACKGROUND: The lateral transpsoas approach to interbody fusion is gaining popularity. Existing literature suggests that perioperative vertebra-related complications include endplate breach owing to aggressive enedplate preparation and poor bone quality. The acute effects of cage subsidence on stabi...

Descripción completa

Detalles Bibliográficos
Autores principales: Santoni, Brandon G., Alexander, Gerald E., Nayak, Aniruddh, Cabezas, Andres, Marulanda, German A., Murtagh, Ryan, Castellvi, Antonio E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier, Inc. 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4300980/
https://www.ncbi.nlm.nih.gov/pubmed/25694896
http://dx.doi.org/10.1016/j.ijsp.2013.09.001
_version_ 1782353593267912704
author Santoni, Brandon G.
Alexander, Gerald E.
Nayak, Aniruddh
Cabezas, Andres
Marulanda, German A.
Murtagh, Ryan
Castellvi, Antonio E.
author_facet Santoni, Brandon G.
Alexander, Gerald E.
Nayak, Aniruddh
Cabezas, Andres
Marulanda, German A.
Murtagh, Ryan
Castellvi, Antonio E.
author_sort Santoni, Brandon G.
collection PubMed
description BACKGROUND: The lateral transpsoas approach to interbody fusion is gaining popularity. Existing literature suggests that perioperative vertebra-related complications include endplate breach owing to aggressive enedplate preparation and poor bone quality. The acute effects of cage subsidence on stabilization and indirect decompression at the affected level are unknown. The purpose of this study was to compare the kinematics and radiographic metrics of indirect decompression in lumbar spines instrumented with laterally placed cages in the presence of inadvertent endplate fracture, which was determined radiographically, to specimens instrumented with lateral cages with intact endplates. METHODS: Five levels in 5 specimens sustained endplate fracture during lateral cage implantation followed by supplementary fixation (pedicle screw/rod [PSR]: n = 1; anterolateral plate [ALP]: n = 4), as part of a larger laboratory-based study. Range of motion (ROM) in these specimens was compared with 13 instrumented specimens with intact endplates. All specimens were scanned using computed tomography (CT) in the intact, noninstrumented condition and after 2-level cage placement with internal fixation under a 400-N follower load. Changes in disc height, foraminal area, and canal area were measured and compared between specimens with intact endplates and fractured endplates. RESULTS: Subsidence in the single PSR specimen and 4 ALP specimens was 6.5 mm and 4.3 ± 2.7 mm (range: 2.2–8.3 mm), respectively. ROM was increased in the PSR and ALP specimens with endplate fracture when compared with instrumented specimens with intact endplates. In 3 ALP specimens with endplate fracture, ROM in some motion planes increased relative to the intact, noninstrumented spine. These increases in ROM were paralleled by increase in cage translations during cyclic loading (up to 3.3 mm) and an unpredictable radiographic outcome with increases or decreases in posterior disc height, foraminal area, and canal area when compared with instrumented specimens with intact endplates. CONCLUSIONS: Endplate fracture and cage subsidence noted radiographically intraoperatively or in the early postoperative period may be indicative of biomechanical instability at the affected level concomitant with a lack of neurologic decompression, which may require revision surgery.
format Online
Article
Text
id pubmed-4300980
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Elsevier, Inc.
record_format MEDLINE/PubMed
spelling pubmed-43009802015-02-18 Effects on inadvertent endplate fracture following lateral cage placement on range of motion and indirect spine decompression in lumbar spine fusion constructs: A cadaveric study Santoni, Brandon G. Alexander, Gerald E. Nayak, Aniruddh Cabezas, Andres Marulanda, German A. Murtagh, Ryan Castellvi, Antonio E. Int J Spine Surg Full Length Article BACKGROUND: The lateral transpsoas approach to interbody fusion is gaining popularity. Existing literature suggests that perioperative vertebra-related complications include endplate breach owing to aggressive enedplate preparation and poor bone quality. The acute effects of cage subsidence on stabilization and indirect decompression at the affected level are unknown. The purpose of this study was to compare the kinematics and radiographic metrics of indirect decompression in lumbar spines instrumented with laterally placed cages in the presence of inadvertent endplate fracture, which was determined radiographically, to specimens instrumented with lateral cages with intact endplates. METHODS: Five levels in 5 specimens sustained endplate fracture during lateral cage implantation followed by supplementary fixation (pedicle screw/rod [PSR]: n = 1; anterolateral plate [ALP]: n = 4), as part of a larger laboratory-based study. Range of motion (ROM) in these specimens was compared with 13 instrumented specimens with intact endplates. All specimens were scanned using computed tomography (CT) in the intact, noninstrumented condition and after 2-level cage placement with internal fixation under a 400-N follower load. Changes in disc height, foraminal area, and canal area were measured and compared between specimens with intact endplates and fractured endplates. RESULTS: Subsidence in the single PSR specimen and 4 ALP specimens was 6.5 mm and 4.3 ± 2.7 mm (range: 2.2–8.3 mm), respectively. ROM was increased in the PSR and ALP specimens with endplate fracture when compared with instrumented specimens with intact endplates. In 3 ALP specimens with endplate fracture, ROM in some motion planes increased relative to the intact, noninstrumented spine. These increases in ROM were paralleled by increase in cage translations during cyclic loading (up to 3.3 mm) and an unpredictable radiographic outcome with increases or decreases in posterior disc height, foraminal area, and canal area when compared with instrumented specimens with intact endplates. CONCLUSIONS: Endplate fracture and cage subsidence noted radiographically intraoperatively or in the early postoperative period may be indicative of biomechanical instability at the affected level concomitant with a lack of neurologic decompression, which may require revision surgery. Elsevier, Inc. 2013-12-01 /pmc/articles/PMC4300980/ /pubmed/25694896 http://dx.doi.org/10.1016/j.ijsp.2013.09.001 Text en © 2013 ISASS - The International Society for the Advancement of Spine Surgery. Published by Elsevier Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Length Article
Santoni, Brandon G.
Alexander, Gerald E.
Nayak, Aniruddh
Cabezas, Andres
Marulanda, German A.
Murtagh, Ryan
Castellvi, Antonio E.
Effects on inadvertent endplate fracture following lateral cage placement on range of motion and indirect spine decompression in lumbar spine fusion constructs: A cadaveric study
title Effects on inadvertent endplate fracture following lateral cage placement on range of motion and indirect spine decompression in lumbar spine fusion constructs: A cadaveric study
title_full Effects on inadvertent endplate fracture following lateral cage placement on range of motion and indirect spine decompression in lumbar spine fusion constructs: A cadaveric study
title_fullStr Effects on inadvertent endplate fracture following lateral cage placement on range of motion and indirect spine decompression in lumbar spine fusion constructs: A cadaveric study
title_full_unstemmed Effects on inadvertent endplate fracture following lateral cage placement on range of motion and indirect spine decompression in lumbar spine fusion constructs: A cadaveric study
title_short Effects on inadvertent endplate fracture following lateral cage placement on range of motion and indirect spine decompression in lumbar spine fusion constructs: A cadaveric study
title_sort effects on inadvertent endplate fracture following lateral cage placement on range of motion and indirect spine decompression in lumbar spine fusion constructs: a cadaveric study
topic Full Length Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4300980/
https://www.ncbi.nlm.nih.gov/pubmed/25694896
http://dx.doi.org/10.1016/j.ijsp.2013.09.001
work_keys_str_mv AT santonibrandong effectsoninadvertentendplatefracturefollowinglateralcageplacementonrangeofmotionandindirectspinedecompressioninlumbarspinefusionconstructsacadavericstudy
AT alexandergeralde effectsoninadvertentendplatefracturefollowinglateralcageplacementonrangeofmotionandindirectspinedecompressioninlumbarspinefusionconstructsacadavericstudy
AT nayakaniruddh effectsoninadvertentendplatefracturefollowinglateralcageplacementonrangeofmotionandindirectspinedecompressioninlumbarspinefusionconstructsacadavericstudy
AT cabezasandres effectsoninadvertentendplatefracturefollowinglateralcageplacementonrangeofmotionandindirectspinedecompressioninlumbarspinefusionconstructsacadavericstudy
AT marulandagermana effectsoninadvertentendplatefracturefollowinglateralcageplacementonrangeofmotionandindirectspinedecompressioninlumbarspinefusionconstructsacadavericstudy
AT murtaghryan effectsoninadvertentendplatefracturefollowinglateralcageplacementonrangeofmotionandindirectspinedecompressioninlumbarspinefusionconstructsacadavericstudy
AT castellviantonioe effectsoninadvertentendplatefracturefollowinglateralcageplacementonrangeofmotionandindirectspinedecompressioninlumbarspinefusionconstructsacadavericstudy