Evaluating Multiplexed Quantitative Phosphopeptide Analysis on a Hybrid Quadrupole Mass Filter/Linear Ion Trap/Orbitrap Mass Spectrometer

[Image: see text] As a driver for many biological processes, phosphorylation remains an area of intense research interest. Advances in multiplexed quantitation utilizing isobaric tags (e.g., TMT and iTRAQ) have the potential to create a new paradigm in quantitative proteomics. New instrumentation an...

Descripción completa

Detalles Bibliográficos
Autores principales: Erickson, Brian K., Jedrychowski, Mark P., McAlister, Graeme C., Everley, Robert A., Kunz, Ryan, Gygi, Steven P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2014
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4303329/
https://www.ncbi.nlm.nih.gov/pubmed/25521595
http://dx.doi.org/10.1021/ac503934f
_version_ 1782353930135535616
author Erickson, Brian K.
Jedrychowski, Mark P.
McAlister, Graeme C.
Everley, Robert A.
Kunz, Ryan
Gygi, Steven P.
author_facet Erickson, Brian K.
Jedrychowski, Mark P.
McAlister, Graeme C.
Everley, Robert A.
Kunz, Ryan
Gygi, Steven P.
author_sort Erickson, Brian K.
collection PubMed
description [Image: see text] As a driver for many biological processes, phosphorylation remains an area of intense research interest. Advances in multiplexed quantitation utilizing isobaric tags (e.g., TMT and iTRAQ) have the potential to create a new paradigm in quantitative proteomics. New instrumentation and software are propelling these multiplexed workflows forward, which results in more accurate, sensitive, and reproducible quantitation across tens of thousands of phosphopeptides. This study assesses the performance of multiplexed quantitative phosphoproteomics on the Orbitrap Fusion mass spectrometer. Utilizing a two-phosphoproteome model of precursor ion interference, we assessed the accuracy of phosphopeptide quantitation across a variety of experimental approaches. These methods included the use of synchronous precursor selection (SPS) to enhance TMT reporter ion intensity and accuracy. We found that (i) ratio distortion remained a problem for phosphopeptide analysis in multiplexed quantitative workflows, (ii) ratio distortion can be overcome by the use of an SPS-MS3 scan, (iii) interfering ions generally possessed a different charge state than the target precursor, and (iv) selecting only the phosphate neutral loss peak (single notch) for the MS3 scan still provided accurate ratio measurements. Remarkably, these data suggest that the underlying cause of interference may not be due to coeluting and cofragmented peptides but instead from consistent, low level background fragmentation. Finally, as a proof-of-concept 10-plex experiment, we compared phosphopeptide levels from five murine brains to five livers. In total, the SPS-MS3 method quantified 38 247 phosphopeptides, corresponding to 11 000 phosphorylation sites. With 10 measurements recorded for each phosphopeptide, this equates to more than 628 000 binary comparisons collected in less than 48 h.
format Online
Article
Text
id pubmed-4303329
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-43033292015-12-18 Evaluating Multiplexed Quantitative Phosphopeptide Analysis on a Hybrid Quadrupole Mass Filter/Linear Ion Trap/Orbitrap Mass Spectrometer Erickson, Brian K. Jedrychowski, Mark P. McAlister, Graeme C. Everley, Robert A. Kunz, Ryan Gygi, Steven P. Anal Chem [Image: see text] As a driver for many biological processes, phosphorylation remains an area of intense research interest. Advances in multiplexed quantitation utilizing isobaric tags (e.g., TMT and iTRAQ) have the potential to create a new paradigm in quantitative proteomics. New instrumentation and software are propelling these multiplexed workflows forward, which results in more accurate, sensitive, and reproducible quantitation across tens of thousands of phosphopeptides. This study assesses the performance of multiplexed quantitative phosphoproteomics on the Orbitrap Fusion mass spectrometer. Utilizing a two-phosphoproteome model of precursor ion interference, we assessed the accuracy of phosphopeptide quantitation across a variety of experimental approaches. These methods included the use of synchronous precursor selection (SPS) to enhance TMT reporter ion intensity and accuracy. We found that (i) ratio distortion remained a problem for phosphopeptide analysis in multiplexed quantitative workflows, (ii) ratio distortion can be overcome by the use of an SPS-MS3 scan, (iii) interfering ions generally possessed a different charge state than the target precursor, and (iv) selecting only the phosphate neutral loss peak (single notch) for the MS3 scan still provided accurate ratio measurements. Remarkably, these data suggest that the underlying cause of interference may not be due to coeluting and cofragmented peptides but instead from consistent, low level background fragmentation. Finally, as a proof-of-concept 10-plex experiment, we compared phosphopeptide levels from five murine brains to five livers. In total, the SPS-MS3 method quantified 38 247 phosphopeptides, corresponding to 11 000 phosphorylation sites. With 10 measurements recorded for each phosphopeptide, this equates to more than 628 000 binary comparisons collected in less than 48 h. American Chemical Society 2014-12-18 2015-01-20 /pmc/articles/PMC4303329/ /pubmed/25521595 http://dx.doi.org/10.1021/ac503934f Text en Copyright © 2014 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Erickson, Brian K.
Jedrychowski, Mark P.
McAlister, Graeme C.
Everley, Robert A.
Kunz, Ryan
Gygi, Steven P.
Evaluating Multiplexed Quantitative Phosphopeptide Analysis on a Hybrid Quadrupole Mass Filter/Linear Ion Trap/Orbitrap Mass Spectrometer
title Evaluating Multiplexed Quantitative Phosphopeptide Analysis on a Hybrid Quadrupole Mass Filter/Linear Ion Trap/Orbitrap Mass Spectrometer
title_full Evaluating Multiplexed Quantitative Phosphopeptide Analysis on a Hybrid Quadrupole Mass Filter/Linear Ion Trap/Orbitrap Mass Spectrometer
title_fullStr Evaluating Multiplexed Quantitative Phosphopeptide Analysis on a Hybrid Quadrupole Mass Filter/Linear Ion Trap/Orbitrap Mass Spectrometer
title_full_unstemmed Evaluating Multiplexed Quantitative Phosphopeptide Analysis on a Hybrid Quadrupole Mass Filter/Linear Ion Trap/Orbitrap Mass Spectrometer
title_short Evaluating Multiplexed Quantitative Phosphopeptide Analysis on a Hybrid Quadrupole Mass Filter/Linear Ion Trap/Orbitrap Mass Spectrometer
title_sort evaluating multiplexed quantitative phosphopeptide analysis on a hybrid quadrupole mass filter/linear ion trap/orbitrap mass spectrometer
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4303329/
https://www.ncbi.nlm.nih.gov/pubmed/25521595
http://dx.doi.org/10.1021/ac503934f
work_keys_str_mv AT ericksonbriank evaluatingmultiplexedquantitativephosphopeptideanalysisonahybridquadrupolemassfilterlineariontraporbitrapmassspectrometer
AT jedrychowskimarkp evaluatingmultiplexedquantitativephosphopeptideanalysisonahybridquadrupolemassfilterlineariontraporbitrapmassspectrometer
AT mcalistergraemec evaluatingmultiplexedquantitativephosphopeptideanalysisonahybridquadrupolemassfilterlineariontraporbitrapmassspectrometer
AT everleyroberta evaluatingmultiplexedquantitativephosphopeptideanalysisonahybridquadrupolemassfilterlineariontraporbitrapmassspectrometer
AT kunzryan evaluatingmultiplexedquantitativephosphopeptideanalysisonahybridquadrupolemassfilterlineariontraporbitrapmassspectrometer
AT gygistevenp evaluatingmultiplexedquantitativephosphopeptideanalysisonahybridquadrupolemassfilterlineariontraporbitrapmassspectrometer