Cargando…
A New Measure for Monitoring Intraoperative Somatosensory Evoked Potentials
OBJECTIVE: To propose a new measure for effective monitoring of intraoperative somatosensory evoked potentials (SEP) and to validate the feasibility of this measure for evoked potentials (EP) and single trials with a retrospective data analysis study. METHODS: The proposed new measure (hereafter, a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Neurosurgical Society
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4303719/ https://www.ncbi.nlm.nih.gov/pubmed/25628803 http://dx.doi.org/10.3340/jkns.2014.56.6.455 |
_version_ | 1782353964759515136 |
---|---|
author | Jin, Seung-Hyun Chung, Chun Kee Kim, Jeong Eun Choi, Young Doo |
author_facet | Jin, Seung-Hyun Chung, Chun Kee Kim, Jeong Eun Choi, Young Doo |
author_sort | Jin, Seung-Hyun |
collection | PubMed |
description | OBJECTIVE: To propose a new measure for effective monitoring of intraoperative somatosensory evoked potentials (SEP) and to validate the feasibility of this measure for evoked potentials (EP) and single trials with a retrospective data analysis study. METHODS: The proposed new measure (hereafter, a slope-measure) was defined as the relative slope of the amplitude and latency at each EP peak compared to the baseline value, which is sensitive to the change in the amplitude and latency simultaneously. We used the slope-measure for EP and single trials and compared the significant change detection time with that of the conventional peak-to-peak method. When applied to single trials, each single trial signal was processed with optimal filters before using the slope-measure. In this retrospective data analysis, 7 patients who underwent cerebral aneurysm clipping surgery for unruptured aneurysm middle cerebral artery (MCA) bifurcation were included. RESULTS: We found that this simple slope-measure has a detection time that is as early or earlier than that of the conventional method; furthermore, using the slope-measure in optimally filtered single trials provides warning signs earlier than that of the conventional method during MCA clipping surgery. CONCLUSION: Our results have confirmed the feasibility of the slope-measure for intraoperative SEP monitoring. This is a novel study that provides a useful measure for either EP or single trials in intraoperative SEP monitoring. |
format | Online Article Text |
id | pubmed-4303719 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Neurosurgical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-43037192015-01-27 A New Measure for Monitoring Intraoperative Somatosensory Evoked Potentials Jin, Seung-Hyun Chung, Chun Kee Kim, Jeong Eun Choi, Young Doo J Korean Neurosurg Soc Laboratory Investigation OBJECTIVE: To propose a new measure for effective monitoring of intraoperative somatosensory evoked potentials (SEP) and to validate the feasibility of this measure for evoked potentials (EP) and single trials with a retrospective data analysis study. METHODS: The proposed new measure (hereafter, a slope-measure) was defined as the relative slope of the amplitude and latency at each EP peak compared to the baseline value, which is sensitive to the change in the amplitude and latency simultaneously. We used the slope-measure for EP and single trials and compared the significant change detection time with that of the conventional peak-to-peak method. When applied to single trials, each single trial signal was processed with optimal filters before using the slope-measure. In this retrospective data analysis, 7 patients who underwent cerebral aneurysm clipping surgery for unruptured aneurysm middle cerebral artery (MCA) bifurcation were included. RESULTS: We found that this simple slope-measure has a detection time that is as early or earlier than that of the conventional method; furthermore, using the slope-measure in optimally filtered single trials provides warning signs earlier than that of the conventional method during MCA clipping surgery. CONCLUSION: Our results have confirmed the feasibility of the slope-measure for intraoperative SEP monitoring. This is a novel study that provides a useful measure for either EP or single trials in intraoperative SEP monitoring. The Korean Neurosurgical Society 2014-12 2014-12-31 /pmc/articles/PMC4303719/ /pubmed/25628803 http://dx.doi.org/10.3340/jkns.2014.56.6.455 Text en Copyright © 2014 The Korean Neurosurgical Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Laboratory Investigation Jin, Seung-Hyun Chung, Chun Kee Kim, Jeong Eun Choi, Young Doo A New Measure for Monitoring Intraoperative Somatosensory Evoked Potentials |
title | A New Measure for Monitoring Intraoperative Somatosensory Evoked Potentials |
title_full | A New Measure for Monitoring Intraoperative Somatosensory Evoked Potentials |
title_fullStr | A New Measure for Monitoring Intraoperative Somatosensory Evoked Potentials |
title_full_unstemmed | A New Measure for Monitoring Intraoperative Somatosensory Evoked Potentials |
title_short | A New Measure for Monitoring Intraoperative Somatosensory Evoked Potentials |
title_sort | new measure for monitoring intraoperative somatosensory evoked potentials |
topic | Laboratory Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4303719/ https://www.ncbi.nlm.nih.gov/pubmed/25628803 http://dx.doi.org/10.3340/jkns.2014.56.6.455 |
work_keys_str_mv | AT jinseunghyun anewmeasureformonitoringintraoperativesomatosensoryevokedpotentials AT chungchunkee anewmeasureformonitoringintraoperativesomatosensoryevokedpotentials AT kimjeongeun anewmeasureformonitoringintraoperativesomatosensoryevokedpotentials AT choiyoungdoo anewmeasureformonitoringintraoperativesomatosensoryevokedpotentials AT jinseunghyun newmeasureformonitoringintraoperativesomatosensoryevokedpotentials AT chungchunkee newmeasureformonitoringintraoperativesomatosensoryevokedpotentials AT kimjeongeun newmeasureformonitoringintraoperativesomatosensoryevokedpotentials AT choiyoungdoo newmeasureformonitoringintraoperativesomatosensoryevokedpotentials |