Cargando…

Irreversible electroporation: Just another form of thermal therapy?

BACKGROUND: Irreversible electroporation (IRE) is (virtually) always called non-thermal despite many reports showing that significant Joule heating occurs. Our first aim is to validate with mathematical simulations that IRE as currently practiced has a non-negligible thermal response. Our second aim...

Descripción completa

Detalles Bibliográficos
Autores principales: van Gemert, Martin J C, Wagstaff, Peter G K, de Bruin, Daniel M, van Leeuwen, Ton G, van der Wal, Allard C, Heger, Michal, van der Geld, Cees W M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BlackWell Publishing Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4305196/
https://www.ncbi.nlm.nih.gov/pubmed/25327875
http://dx.doi.org/10.1002/pros.22913
_version_ 1782354191556018176
author van Gemert, Martin J C
Wagstaff, Peter G K
de Bruin, Daniel M
van Leeuwen, Ton G
van der Wal, Allard C
Heger, Michal
van der Geld, Cees W M
author_facet van Gemert, Martin J C
Wagstaff, Peter G K
de Bruin, Daniel M
van Leeuwen, Ton G
van der Wal, Allard C
Heger, Michal
van der Geld, Cees W M
author_sort van Gemert, Martin J C
collection PubMed
description BACKGROUND: Irreversible electroporation (IRE) is (virtually) always called non-thermal despite many reports showing that significant Joule heating occurs. Our first aim is to validate with mathematical simulations that IRE as currently practiced has a non-negligible thermal response. Our second aim is to present a method that allows simple temperature estimation to aid IRE treatment planning. METHODS: We derived an approximate analytical solution of the bio-heat equation for multiple 2-needle IRE pulses in an electrically conducting medium, with and without a blood vessel, and incorporated published observations that an electric pulse increases the medium's electric conductance. RESULTS: IRE simulation in prostate-resembling tissue shows thermal lesions with 67–92°C temperatures, which match the positions of the coagulative necrotic lesions seen in an experimental study. Simulation of IRE around a blood vessel when blood flow removes the heated blood between pulses confirms clinical observations that the perivascular tissue is thermally injured without affecting vascular patency. CONCLUSIONS: The demonstration that significant Joule heating surrounds current multiple-pulsed IRE practice may contribute to future in-depth discussions on this thermal issue. This is an important subject because it has long been under-exposed in literature. Its awareness pleads for preventing IRE from calling “non-thermal” in future publications, in order to provide IRE-users with the most accurate information possible. The prospect of thermal treatment planning as outlined in this paper likely aids to the important further successful dissemination of IRE in interventional medicine. Prostate 75:332–335, 2015. © 2014 The Authors. The Prostate Published by Wiley Periodicals, Inc.
format Online
Article
Text
id pubmed-4305196
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BlackWell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-43051962015-02-02 Irreversible electroporation: Just another form of thermal therapy? van Gemert, Martin J C Wagstaff, Peter G K de Bruin, Daniel M van Leeuwen, Ton G van der Wal, Allard C Heger, Michal van der Geld, Cees W M Prostate Original Articles BACKGROUND: Irreversible electroporation (IRE) is (virtually) always called non-thermal despite many reports showing that significant Joule heating occurs. Our first aim is to validate with mathematical simulations that IRE as currently practiced has a non-negligible thermal response. Our second aim is to present a method that allows simple temperature estimation to aid IRE treatment planning. METHODS: We derived an approximate analytical solution of the bio-heat equation for multiple 2-needle IRE pulses in an electrically conducting medium, with and without a blood vessel, and incorporated published observations that an electric pulse increases the medium's electric conductance. RESULTS: IRE simulation in prostate-resembling tissue shows thermal lesions with 67–92°C temperatures, which match the positions of the coagulative necrotic lesions seen in an experimental study. Simulation of IRE around a blood vessel when blood flow removes the heated blood between pulses confirms clinical observations that the perivascular tissue is thermally injured without affecting vascular patency. CONCLUSIONS: The demonstration that significant Joule heating surrounds current multiple-pulsed IRE practice may contribute to future in-depth discussions on this thermal issue. This is an important subject because it has long been under-exposed in literature. Its awareness pleads for preventing IRE from calling “non-thermal” in future publications, in order to provide IRE-users with the most accurate information possible. The prospect of thermal treatment planning as outlined in this paper likely aids to the important further successful dissemination of IRE in interventional medicine. Prostate 75:332–335, 2015. © 2014 The Authors. The Prostate Published by Wiley Periodicals, Inc. BlackWell Publishing Ltd 2015-02 2014-10-18 /pmc/articles/PMC4305196/ /pubmed/25327875 http://dx.doi.org/10.1002/pros.22913 Text en © 2014 The Authors. The Prostate Published by Wiley Periodicals, Inc. http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Articles
van Gemert, Martin J C
Wagstaff, Peter G K
de Bruin, Daniel M
van Leeuwen, Ton G
van der Wal, Allard C
Heger, Michal
van der Geld, Cees W M
Irreversible electroporation: Just another form of thermal therapy?
title Irreversible electroporation: Just another form of thermal therapy?
title_full Irreversible electroporation: Just another form of thermal therapy?
title_fullStr Irreversible electroporation: Just another form of thermal therapy?
title_full_unstemmed Irreversible electroporation: Just another form of thermal therapy?
title_short Irreversible electroporation: Just another form of thermal therapy?
title_sort irreversible electroporation: just another form of thermal therapy?
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4305196/
https://www.ncbi.nlm.nih.gov/pubmed/25327875
http://dx.doi.org/10.1002/pros.22913
work_keys_str_mv AT vangemertmartinjc irreversibleelectroporationjustanotherformofthermaltherapy
AT wagstaffpetergk irreversibleelectroporationjustanotherformofthermaltherapy
AT debruindanielm irreversibleelectroporationjustanotherformofthermaltherapy
AT vanleeuwentong irreversibleelectroporationjustanotherformofthermaltherapy
AT vanderwalallardc irreversibleelectroporationjustanotherformofthermaltherapy
AT hegermichal irreversibleelectroporationjustanotherformofthermaltherapy
AT vandergeldceeswm irreversibleelectroporationjustanotherformofthermaltherapy