Cargando…

Carpal Tunnel Syndrome Assessment with Ultrasonography: Value of Inlet-to-Outlet Median Nerve Area Ratio in Patients versus Healthy Volunteers

OBJECTIVE: To evaluate the diagnostic value of the Inlet-to-outlet median nerve area ratio (IOR) in patients with clinically and electrophysiologically confirmed carpal tunnel syndrome (CTS). METHODS: Forty-six wrists in 46 consecutive patients with clinical and electrodiagnostic evidence of CTS and...

Descripción completa

Detalles Bibliográficos
Autores principales: Fu, Tengfei, Cao, Manlin, Liu, Fang, Zhu, Jiaan, Ye, Dongmei, Feng, Xianxuan, Xu, Yiming, Wang, Gang, Bai, Yuehong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4305299/
https://www.ncbi.nlm.nih.gov/pubmed/25617835
http://dx.doi.org/10.1371/journal.pone.0116777
_version_ 1782354213602328576
author Fu, Tengfei
Cao, Manlin
Liu, Fang
Zhu, Jiaan
Ye, Dongmei
Feng, Xianxuan
Xu, Yiming
Wang, Gang
Bai, Yuehong
author_facet Fu, Tengfei
Cao, Manlin
Liu, Fang
Zhu, Jiaan
Ye, Dongmei
Feng, Xianxuan
Xu, Yiming
Wang, Gang
Bai, Yuehong
author_sort Fu, Tengfei
collection PubMed
description OBJECTIVE: To evaluate the diagnostic value of the Inlet-to-outlet median nerve area ratio (IOR) in patients with clinically and electrophysiologically confirmed carpal tunnel syndrome (CTS). METHODS: Forty-six wrists in 46 consecutive patients with clinical and electrodiagnostic evidence of CTS and forty-four wrists in 44 healthy volunteers were examined with ultrasonography. The cross-sectional area (CSA) of the median nerve was measured at the carpal tunnel inlet (the level of scaphoid-pisiform) and outlet (the level of the hook of the hamate), and the IOR was calculated for each wrist. Ultrasonography and electrodiagnostic tests were performed under blinded conditions. Electrodiagnostic testing combined with clinical symptoms were considered to be the gold standard test. Receiver operating characteristic (ROC) curves were used to evaluate the diagnostic value between the inlet CSA and IOR. RESULTS: The study population included 16 men and 30 women (mean age, 45.3 years; range, 18–83 years). The control population included 18 men and 26 women (mean age, 50.4 years; range, 18–79 years). The mean inlet CSA was 8.7 mm(2) in healthy controls and 14.6mm(2) in CTS group (P<0.001). The mean IOR in healthy volunteers (1.0) was smaller than that in patients (1.6, P<0.001). Receiver operating characteristic analysis revealed a diagnostic advantage to using the IOR rather than the inlet CSA (P<0.01). An IOR cutoff value of ≥ 1.3 would yield 93% specificity and 91% sensitivity in the diagnosis of CTS. CONCLUSION: The IOR of median nerve area promises to be an effective means in the diagnosis of CTS. A large-scale, randomized controlled trial is required to determine how and when this parameter will be used.
format Online
Article
Text
id pubmed-4305299
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-43052992015-01-30 Carpal Tunnel Syndrome Assessment with Ultrasonography: Value of Inlet-to-Outlet Median Nerve Area Ratio in Patients versus Healthy Volunteers Fu, Tengfei Cao, Manlin Liu, Fang Zhu, Jiaan Ye, Dongmei Feng, Xianxuan Xu, Yiming Wang, Gang Bai, Yuehong PLoS One Research Article OBJECTIVE: To evaluate the diagnostic value of the Inlet-to-outlet median nerve area ratio (IOR) in patients with clinically and electrophysiologically confirmed carpal tunnel syndrome (CTS). METHODS: Forty-six wrists in 46 consecutive patients with clinical and electrodiagnostic evidence of CTS and forty-four wrists in 44 healthy volunteers were examined with ultrasonography. The cross-sectional area (CSA) of the median nerve was measured at the carpal tunnel inlet (the level of scaphoid-pisiform) and outlet (the level of the hook of the hamate), and the IOR was calculated for each wrist. Ultrasonography and electrodiagnostic tests were performed under blinded conditions. Electrodiagnostic testing combined with clinical symptoms were considered to be the gold standard test. Receiver operating characteristic (ROC) curves were used to evaluate the diagnostic value between the inlet CSA and IOR. RESULTS: The study population included 16 men and 30 women (mean age, 45.3 years; range, 18–83 years). The control population included 18 men and 26 women (mean age, 50.4 years; range, 18–79 years). The mean inlet CSA was 8.7 mm(2) in healthy controls and 14.6mm(2) in CTS group (P<0.001). The mean IOR in healthy volunteers (1.0) was smaller than that in patients (1.6, P<0.001). Receiver operating characteristic analysis revealed a diagnostic advantage to using the IOR rather than the inlet CSA (P<0.01). An IOR cutoff value of ≥ 1.3 would yield 93% specificity and 91% sensitivity in the diagnosis of CTS. CONCLUSION: The IOR of median nerve area promises to be an effective means in the diagnosis of CTS. A large-scale, randomized controlled trial is required to determine how and when this parameter will be used. Public Library of Science 2015-01-24 /pmc/articles/PMC4305299/ /pubmed/25617835 http://dx.doi.org/10.1371/journal.pone.0116777 Text en © 2015 Fu et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Fu, Tengfei
Cao, Manlin
Liu, Fang
Zhu, Jiaan
Ye, Dongmei
Feng, Xianxuan
Xu, Yiming
Wang, Gang
Bai, Yuehong
Carpal Tunnel Syndrome Assessment with Ultrasonography: Value of Inlet-to-Outlet Median Nerve Area Ratio in Patients versus Healthy Volunteers
title Carpal Tunnel Syndrome Assessment with Ultrasonography: Value of Inlet-to-Outlet Median Nerve Area Ratio in Patients versus Healthy Volunteers
title_full Carpal Tunnel Syndrome Assessment with Ultrasonography: Value of Inlet-to-Outlet Median Nerve Area Ratio in Patients versus Healthy Volunteers
title_fullStr Carpal Tunnel Syndrome Assessment with Ultrasonography: Value of Inlet-to-Outlet Median Nerve Area Ratio in Patients versus Healthy Volunteers
title_full_unstemmed Carpal Tunnel Syndrome Assessment with Ultrasonography: Value of Inlet-to-Outlet Median Nerve Area Ratio in Patients versus Healthy Volunteers
title_short Carpal Tunnel Syndrome Assessment with Ultrasonography: Value of Inlet-to-Outlet Median Nerve Area Ratio in Patients versus Healthy Volunteers
title_sort carpal tunnel syndrome assessment with ultrasonography: value of inlet-to-outlet median nerve area ratio in patients versus healthy volunteers
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4305299/
https://www.ncbi.nlm.nih.gov/pubmed/25617835
http://dx.doi.org/10.1371/journal.pone.0116777
work_keys_str_mv AT futengfei carpaltunnelsyndromeassessmentwithultrasonographyvalueofinlettooutletmediannervearearatioinpatientsversushealthyvolunteers
AT caomanlin carpaltunnelsyndromeassessmentwithultrasonographyvalueofinlettooutletmediannervearearatioinpatientsversushealthyvolunteers
AT liufang carpaltunnelsyndromeassessmentwithultrasonographyvalueofinlettooutletmediannervearearatioinpatientsversushealthyvolunteers
AT zhujiaan carpaltunnelsyndromeassessmentwithultrasonographyvalueofinlettooutletmediannervearearatioinpatientsversushealthyvolunteers
AT yedongmei carpaltunnelsyndromeassessmentwithultrasonographyvalueofinlettooutletmediannervearearatioinpatientsversushealthyvolunteers
AT fengxianxuan carpaltunnelsyndromeassessmentwithultrasonographyvalueofinlettooutletmediannervearearatioinpatientsversushealthyvolunteers
AT xuyiming carpaltunnelsyndromeassessmentwithultrasonographyvalueofinlettooutletmediannervearearatioinpatientsversushealthyvolunteers
AT wanggang carpaltunnelsyndromeassessmentwithultrasonographyvalueofinlettooutletmediannervearearatioinpatientsversushealthyvolunteers
AT baiyuehong carpaltunnelsyndromeassessmentwithultrasonographyvalueofinlettooutletmediannervearearatioinpatientsversushealthyvolunteers