AIMS: There are limited and contradictory data on the effects of CRT with implantable cardioverter defibrillator (CRT-D) on mortality as compared with CRT with pacemaker (CRT-P). METHODS AND RESULTS: We evaluated the long-term outcome of patients implanted with a CRT-D or CRT-P device in our high-vo...

Descripción completa

Detalles Bibliográficos
Autores principales: Kutyifa, Valentina, Geller, Laszlo, Bogyi, Peter, Zima, Endre, Aktas, Mehmet K, Ozcan, Emin Evren, Becker, David, Nagy, Vivien Klaudia, Kosztin, Annamaria, Szilagyi, Szabolcs, Merkely, Bela
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4309510/
https://www.ncbi.nlm.nih.gov/pubmed/25379962
http://dx.doi.org/10.1002/ejhf.185
Descripción
Sumario:AIMS: There are limited and contradictory data on the effects of CRT with implantable cardioverter defibrillator (CRT-D) on mortality as compared with CRT with pacemaker (CRT-P). METHODS AND RESULTS: We evaluated the long-term outcome of patients implanted with a CRT-D or CRT-P device in our high-volume single-centre experience. Data on all-cause mortality were derived from clinic visits and the Hungarian National Healthcare Fund Death Registry. Kaplan–Meier survival analyses and multivariate Cox regression models were used to evaluate all-cause mortality in patients with CRT-D vs. CRT-P, stratified by the aetiology of cardiomyopathy. From 2000 to 2011, 1122 CRT devices, 693 CRT-P (LVEF 28.2 ± 7.4%) and 429 CRT-D (LVEF 27.6 ± 6.4%), were implanted at our centre. During the median follow-up of 28 months, 379 patients died from any cause, 250 patients (36%) with an implanted CRT-P and 129 patients (30%) with an implanted CRT-D. There was no evidence of mortality benefit in patients implanted with a CRT-D compared with a CRT-P in the total cohort [hazard ratio (HR) 0.98, 95% confidence interval (CI) 0.73–1.32, P = 0.884]. In patients with ischaemic cardiomyopathy, CRT-D treatment was associated with a significant 30% risk reduction in all-cause mortality compared with an implanted CRT-P (HR 0.70, 95% CI 0.51–0.97, P = 0.03). In non-ischaemic patients, there was no mortality benefit of CRT-D over CRT-P (HR 0.98, 95% CI 0.73–1.32, P = 0.894, interaction P-value = 0.15). CONCLUSIONS: In heart failure patients with ischaemic cardiomyopathy, CRT-D was associated with a mortality benefit compared with CRT-P, but no benefit of CRT-D over CRT-P in mortality was observed in non-ischaemic cardiomyopathy.