Thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring
The rationale for intrathoracic impedance (Z) detection of worsening heart failure (HF) presupposes that changes in Z reflect changes in pulmonary congestion, but is confounded by poor specificity in clinical trials. We therefore tested the hypothesis that Z is primarily affected by tissue/water con...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4309910/ https://www.ncbi.nlm.nih.gov/pubmed/24619657 http://dx.doi.org/10.1007/s10877-014-9570-x |
_version_ | 1782354771047350272 |
---|---|
author | Charles, Christopher J. Rademaker, Miriam T. Melton, Iain C. Gutfinger, Dan Eigler, Neal L. Qu, Fujian Troughton, Richard W. |
author_facet | Charles, Christopher J. Rademaker, Miriam T. Melton, Iain C. Gutfinger, Dan Eigler, Neal L. Qu, Fujian Troughton, Richard W. |
author_sort | Charles, Christopher J. |
collection | PubMed |
description | The rationale for intrathoracic impedance (Z) detection of worsening heart failure (HF) presupposes that changes in Z reflect changes in pulmonary congestion, but is confounded by poor specificity in clinical trials. We therefore tested the hypothesis that Z is primarily affected by tissue/water content in proximity to electrodes rather than by lung water distribution between electrodes through the use of a new computational model for deriving the near-field impedance contributions from the various electrodes. Six sheep were implanted with a left atrial pressure (LAP) monitor and a cardiac resynchronization therapy device which measured Z from six vectors comprising of five electrodes. The vector-based Z was modelled as the summation of the near-field impedances of the two electrodes forming the vector. During volume expansion an acute increase in LAP resulted in simultaneous reductions in the near-field impedances of the intra-cardiac electrodes, while the subcutaneous electrode showed several hours of lag (all p < 0.001). In contrast, during the simulated formation of device-pocket edema (induced by fluid injection) the near-field impedance of the subcutaneous electrode had an instantaneous response, while the intra-cardiac electrodes had a minimal inconsistent response. This study suggests that the primary contribution to the vector based Z is from the tissue/water in proximity to the individual electrodes. This novel finding may help explain the limited utility of Z for detecting worsening HF. |
format | Online Article Text |
id | pubmed-4309910 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-43099102015-02-02 Thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring Charles, Christopher J. Rademaker, Miriam T. Melton, Iain C. Gutfinger, Dan Eigler, Neal L. Qu, Fujian Troughton, Richard W. J Clin Monit Comput Original Research The rationale for intrathoracic impedance (Z) detection of worsening heart failure (HF) presupposes that changes in Z reflect changes in pulmonary congestion, but is confounded by poor specificity in clinical trials. We therefore tested the hypothesis that Z is primarily affected by tissue/water content in proximity to electrodes rather than by lung water distribution between electrodes through the use of a new computational model for deriving the near-field impedance contributions from the various electrodes. Six sheep were implanted with a left atrial pressure (LAP) monitor and a cardiac resynchronization therapy device which measured Z from six vectors comprising of five electrodes. The vector-based Z was modelled as the summation of the near-field impedances of the two electrodes forming the vector. During volume expansion an acute increase in LAP resulted in simultaneous reductions in the near-field impedances of the intra-cardiac electrodes, while the subcutaneous electrode showed several hours of lag (all p < 0.001). In contrast, during the simulated formation of device-pocket edema (induced by fluid injection) the near-field impedance of the subcutaneous electrode had an instantaneous response, while the intra-cardiac electrodes had a minimal inconsistent response. This study suggests that the primary contribution to the vector based Z is from the tissue/water in proximity to the individual electrodes. This novel finding may help explain the limited utility of Z for detecting worsening HF. Springer Netherlands 2014-03-12 2015 /pmc/articles/PMC4309910/ /pubmed/24619657 http://dx.doi.org/10.1007/s10877-014-9570-x Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Original Research Charles, Christopher J. Rademaker, Miriam T. Melton, Iain C. Gutfinger, Dan Eigler, Neal L. Qu, Fujian Troughton, Richard W. Thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring |
title | Thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring |
title_full | Thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring |
title_fullStr | Thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring |
title_full_unstemmed | Thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring |
title_short | Thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring |
title_sort | thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4309910/ https://www.ncbi.nlm.nih.gov/pubmed/24619657 http://dx.doi.org/10.1007/s10877-014-9570-x |
work_keys_str_mv | AT charleschristopherj thoracicimpedancemeasurestissuecharacteristicsinthevicinityoftheelectrodesnotinterveninglungwaterimplicationsforheartfailuremonitoring AT rademakermiriamt thoracicimpedancemeasurestissuecharacteristicsinthevicinityoftheelectrodesnotinterveninglungwaterimplicationsforheartfailuremonitoring AT meltoniainc thoracicimpedancemeasurestissuecharacteristicsinthevicinityoftheelectrodesnotinterveninglungwaterimplicationsforheartfailuremonitoring AT gutfingerdan thoracicimpedancemeasurestissuecharacteristicsinthevicinityoftheelectrodesnotinterveninglungwaterimplicationsforheartfailuremonitoring AT eiglerneall thoracicimpedancemeasurestissuecharacteristicsinthevicinityoftheelectrodesnotinterveninglungwaterimplicationsforheartfailuremonitoring AT qufujian thoracicimpedancemeasurestissuecharacteristicsinthevicinityoftheelectrodesnotinterveninglungwaterimplicationsforheartfailuremonitoring AT troughtonrichardw thoracicimpedancemeasurestissuecharacteristicsinthevicinityoftheelectrodesnotinterveninglungwaterimplicationsforheartfailuremonitoring |