Cargando…
A Case of Transvenous Pacemaker Implantation in a 10-year-old Patient
Objective: The aim of this report was to discuss the type, timing, and surgical techniques of permanent pacemaker implantation in a juvenile patient. Patients: A 17-year-old girl with Down syndrome and congenital heart defects comprised of ventricular septal defects (VSD) and patent ductus arteriosu...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Association of Rural Medicine
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4310050/ https://www.ncbi.nlm.nih.gov/pubmed/25648084 http://dx.doi.org/10.2185/jrm.2879 |
_version_ | 1782354796505726976 |
---|---|
author | Liu, Jiajia Shimada, Yasuyuki |
author_facet | Liu, Jiajia Shimada, Yasuyuki |
author_sort | Liu, Jiajia |
collection | PubMed |
description | Objective: The aim of this report was to discuss the type, timing, and surgical techniques of permanent pacemaker implantation in a juvenile patient. Patients: A 17-year-old girl with Down syndrome and congenital heart defects comprised of ventricular septal defects (VSD) and patent ductus arteriosus (PDA) suffered from postoperative complete atrioventricular block (AVB) when she was 7 months old. Methods and Results: An epicardial pacemaker was implanted just after the occurrence of complete AVB. Due to the pacing threshold of a ventricular lead not being good, the battery showed rapid depletion. Her generator had to be exchanged under general anesthesia every 2–3 years. When she was 10 years old, we implanted a permanent pacemaker transvenously by using cutdown, screw-in and subpectoral pocket techniques. She has shown a satisfactory outcome since then. Conclusion: Transvenous pacemaker implantation was safe and effective in our young patient without any complications. The timing of surgery and surgical technique are quite important for pacemaker implantation in juvenile patients. |
format | Online Article Text |
id | pubmed-4310050 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | The Japanese Association of Rural Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-43100502015-02-03 A Case of Transvenous Pacemaker Implantation in a 10-year-old Patient Liu, Jiajia Shimada, Yasuyuki J Rural Med Case Report Objective: The aim of this report was to discuss the type, timing, and surgical techniques of permanent pacemaker implantation in a juvenile patient. Patients: A 17-year-old girl with Down syndrome and congenital heart defects comprised of ventricular septal defects (VSD) and patent ductus arteriosus (PDA) suffered from postoperative complete atrioventricular block (AVB) when she was 7 months old. Methods and Results: An epicardial pacemaker was implanted just after the occurrence of complete AVB. Due to the pacing threshold of a ventricular lead not being good, the battery showed rapid depletion. Her generator had to be exchanged under general anesthesia every 2–3 years. When she was 10 years old, we implanted a permanent pacemaker transvenously by using cutdown, screw-in and subpectoral pocket techniques. She has shown a satisfactory outcome since then. Conclusion: Transvenous pacemaker implantation was safe and effective in our young patient without any complications. The timing of surgery and surgical technique are quite important for pacemaker implantation in juvenile patients. The Japanese Association of Rural Medicine 2013-12-18 2014 /pmc/articles/PMC4310050/ /pubmed/25648084 http://dx.doi.org/10.2185/jrm.2879 Text en ©2014 The Japanese Association of Rural Medicine http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. |
spellingShingle | Case Report Liu, Jiajia Shimada, Yasuyuki A Case of Transvenous Pacemaker Implantation in a 10-year-old Patient |
title | A Case of Transvenous Pacemaker Implantation in a 10-year-old
Patient |
title_full | A Case of Transvenous Pacemaker Implantation in a 10-year-old
Patient |
title_fullStr | A Case of Transvenous Pacemaker Implantation in a 10-year-old
Patient |
title_full_unstemmed | A Case of Transvenous Pacemaker Implantation in a 10-year-old
Patient |
title_short | A Case of Transvenous Pacemaker Implantation in a 10-year-old
Patient |
title_sort | case of transvenous pacemaker implantation in a 10-year-old
patient |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4310050/ https://www.ncbi.nlm.nih.gov/pubmed/25648084 http://dx.doi.org/10.2185/jrm.2879 |
work_keys_str_mv | AT liujiajia acaseoftransvenouspacemakerimplantationina10yearoldpatient AT shimadayasuyuki acaseoftransvenouspacemakerimplantationina10yearoldpatient AT liujiajia caseoftransvenouspacemakerimplantationina10yearoldpatient AT shimadayasuyuki caseoftransvenouspacemakerimplantationina10yearoldpatient |