Cargando…
Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias
BACKGROUND: Randomized studies of implantable cardioverter defibrillators (ICD) have excluded sudden cardiac death survivors who had revascularization before or after an arrhythmic event. To evaluate the role of ICD and the effects of clinical variables including degree of revascularization, we stud...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Blackwell Publishing Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4310357/ https://www.ncbi.nlm.nih.gov/pubmed/25146702 http://dx.doi.org/10.1161/JAHA.113.000686 |
_version_ | 1782354856991784960 |
---|---|
author | Nageh, Maged F. Kim, John J. Chen, Lie‐Hong Yao, Janis F. |
author_facet | Nageh, Maged F. Kim, John J. Chen, Lie‐Hong Yao, Janis F. |
author_sort | Nageh, Maged F. |
collection | PubMed |
description | BACKGROUND: Randomized studies of implantable cardioverter defibrillators (ICD) have excluded sudden cardiac death survivors who had revascularization before or after an arrhythmic event. To evaluate the role of ICD and the effects of clinical variables including degree of revascularization, we studied cardiac surgery patients who had an ICD implanted for sustained perioperative ventricular arrhythmias. METHODS AND RESULTS: The electronic database for Southern California Kaiser Foundation hospitals was searched for patients who had cardiac surgery between 1999 and 2005 and an ICD implanted within 3 months of surgery. One hundred sixty‐four patients were identified; 93/164 had an ICD for sustained pre‐ or postoperative ventricular tachycardia or fibrillation requiring resuscitation. Records were reviewed for the following: presenting arrhythmia, ejection fraction, and degree of revascularization. The primary end point was total mortality (TM) and/or appropriate ICD therapy (ICD‐T), and secondary end points are TM and ICD‐T. During the mean follow up of 49 months, the primary endpoint of TM+ICD‐T and individual end points of TM and ICD‐T were observed in 52 (56%), 35 (38%), and 28 (30%) patients, respectively, with 55% of TM, and 23% of ICD‐T occurring within 2 years of implant. In multivariate risk analysis, none of the following was associated with any of the end points: incomplete revascularization, presenting ventricular arrhythmia, and timing of arrhythmias. CONCLUSION: Our data supports the recent guidelines for ICD in this cohort of patients, as the presence of irreversible substrate and triggers of ventricular arrhythmias, cannot be reliably excluded even with complete revascularization. Further studies are needed to understand this complex group of patients. |
format | Online Article Text |
id | pubmed-4310357 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Blackwell Publishing Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-43103572015-02-10 Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias Nageh, Maged F. Kim, John J. Chen, Lie‐Hong Yao, Janis F. J Am Heart Assoc Original Research BACKGROUND: Randomized studies of implantable cardioverter defibrillators (ICD) have excluded sudden cardiac death survivors who had revascularization before or after an arrhythmic event. To evaluate the role of ICD and the effects of clinical variables including degree of revascularization, we studied cardiac surgery patients who had an ICD implanted for sustained perioperative ventricular arrhythmias. METHODS AND RESULTS: The electronic database for Southern California Kaiser Foundation hospitals was searched for patients who had cardiac surgery between 1999 and 2005 and an ICD implanted within 3 months of surgery. One hundred sixty‐four patients were identified; 93/164 had an ICD for sustained pre‐ or postoperative ventricular tachycardia or fibrillation requiring resuscitation. Records were reviewed for the following: presenting arrhythmia, ejection fraction, and degree of revascularization. The primary end point was total mortality (TM) and/or appropriate ICD therapy (ICD‐T), and secondary end points are TM and ICD‐T. During the mean follow up of 49 months, the primary endpoint of TM+ICD‐T and individual end points of TM and ICD‐T were observed in 52 (56%), 35 (38%), and 28 (30%) patients, respectively, with 55% of TM, and 23% of ICD‐T occurring within 2 years of implant. In multivariate risk analysis, none of the following was associated with any of the end points: incomplete revascularization, presenting ventricular arrhythmia, and timing of arrhythmias. CONCLUSION: Our data supports the recent guidelines for ICD in this cohort of patients, as the presence of irreversible substrate and triggers of ventricular arrhythmias, cannot be reliably excluded even with complete revascularization. Further studies are needed to understand this complex group of patients. Blackwell Publishing Ltd 2014-08-21 /pmc/articles/PMC4310357/ /pubmed/25146702 http://dx.doi.org/10.1161/JAHA.113.000686 Text en © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial (http://creativecommons.org/licenses/by-nc/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Original Research Nageh, Maged F. Kim, John J. Chen, Lie‐Hong Yao, Janis F. Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias |
title | Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias |
title_full | Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias |
title_fullStr | Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias |
title_full_unstemmed | Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias |
title_short | Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias |
title_sort | implantable defibrillators for secondary prevention of sudden cardiac death in cardiac surgery patients with perioperative ventricular arrhythmias |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4310357/ https://www.ncbi.nlm.nih.gov/pubmed/25146702 http://dx.doi.org/10.1161/JAHA.113.000686 |
work_keys_str_mv | AT nagehmagedf implantabledefibrillatorsforsecondarypreventionofsuddencardiacdeathincardiacsurgerypatientswithperioperativeventriculararrhythmias AT kimjohnj implantabledefibrillatorsforsecondarypreventionofsuddencardiacdeathincardiacsurgerypatientswithperioperativeventriculararrhythmias AT chenliehong implantabledefibrillatorsforsecondarypreventionofsuddencardiacdeathincardiacsurgerypatientswithperioperativeventriculararrhythmias AT yaojanisf implantabledefibrillatorsforsecondarypreventionofsuddencardiacdeathincardiacsurgerypatientswithperioperativeventriculararrhythmias |