Cargando…

Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias

BACKGROUND: Randomized studies of implantable cardioverter defibrillators (ICD) have excluded sudden cardiac death survivors who had revascularization before or after an arrhythmic event. To evaluate the role of ICD and the effects of clinical variables including degree of revascularization, we stud...

Descripción completa

Detalles Bibliográficos
Autores principales: Nageh, Maged F., Kim, John J., Chen, Lie‐Hong, Yao, Janis F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4310357/
https://www.ncbi.nlm.nih.gov/pubmed/25146702
http://dx.doi.org/10.1161/JAHA.113.000686
_version_ 1782354856991784960
author Nageh, Maged F.
Kim, John J.
Chen, Lie‐Hong
Yao, Janis F.
author_facet Nageh, Maged F.
Kim, John J.
Chen, Lie‐Hong
Yao, Janis F.
author_sort Nageh, Maged F.
collection PubMed
description BACKGROUND: Randomized studies of implantable cardioverter defibrillators (ICD) have excluded sudden cardiac death survivors who had revascularization before or after an arrhythmic event. To evaluate the role of ICD and the effects of clinical variables including degree of revascularization, we studied cardiac surgery patients who had an ICD implanted for sustained perioperative ventricular arrhythmias. METHODS AND RESULTS: The electronic database for Southern California Kaiser Foundation hospitals was searched for patients who had cardiac surgery between 1999 and 2005 and an ICD implanted within 3 months of surgery. One hundred sixty‐four patients were identified; 93/164 had an ICD for sustained pre‐ or postoperative ventricular tachycardia or fibrillation requiring resuscitation. Records were reviewed for the following: presenting arrhythmia, ejection fraction, and degree of revascularization. The primary end point was total mortality (TM) and/or appropriate ICD therapy (ICD‐T), and secondary end points are TM and ICD‐T. During the mean follow up of 49 months, the primary endpoint of TM+ICD‐T and individual end points of TM and ICD‐T were observed in 52 (56%), 35 (38%), and 28 (30%) patients, respectively, with 55% of TM, and 23% of ICD‐T occurring within 2 years of implant. In multivariate risk analysis, none of the following was associated with any of the end points: incomplete revascularization, presenting ventricular arrhythmia, and timing of arrhythmias. CONCLUSION: Our data supports the recent guidelines for ICD in this cohort of patients, as the presence of irreversible substrate and triggers of ventricular arrhythmias, cannot be reliably excluded even with complete revascularization. Further studies are needed to understand this complex group of patients.
format Online
Article
Text
id pubmed-4310357
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Blackwell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-43103572015-02-10 Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias Nageh, Maged F. Kim, John J. Chen, Lie‐Hong Yao, Janis F. J Am Heart Assoc Original Research BACKGROUND: Randomized studies of implantable cardioverter defibrillators (ICD) have excluded sudden cardiac death survivors who had revascularization before or after an arrhythmic event. To evaluate the role of ICD and the effects of clinical variables including degree of revascularization, we studied cardiac surgery patients who had an ICD implanted for sustained perioperative ventricular arrhythmias. METHODS AND RESULTS: The electronic database for Southern California Kaiser Foundation hospitals was searched for patients who had cardiac surgery between 1999 and 2005 and an ICD implanted within 3 months of surgery. One hundred sixty‐four patients were identified; 93/164 had an ICD for sustained pre‐ or postoperative ventricular tachycardia or fibrillation requiring resuscitation. Records were reviewed for the following: presenting arrhythmia, ejection fraction, and degree of revascularization. The primary end point was total mortality (TM) and/or appropriate ICD therapy (ICD‐T), and secondary end points are TM and ICD‐T. During the mean follow up of 49 months, the primary endpoint of TM+ICD‐T and individual end points of TM and ICD‐T were observed in 52 (56%), 35 (38%), and 28 (30%) patients, respectively, with 55% of TM, and 23% of ICD‐T occurring within 2 years of implant. In multivariate risk analysis, none of the following was associated with any of the end points: incomplete revascularization, presenting ventricular arrhythmia, and timing of arrhythmias. CONCLUSION: Our data supports the recent guidelines for ICD in this cohort of patients, as the presence of irreversible substrate and triggers of ventricular arrhythmias, cannot be reliably excluded even with complete revascularization. Further studies are needed to understand this complex group of patients. Blackwell Publishing Ltd 2014-08-21 /pmc/articles/PMC4310357/ /pubmed/25146702 http://dx.doi.org/10.1161/JAHA.113.000686 Text en © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial (http://creativecommons.org/licenses/by-nc/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Research
Nageh, Maged F.
Kim, John J.
Chen, Lie‐Hong
Yao, Janis F.
Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias
title Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias
title_full Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias
title_fullStr Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias
title_full_unstemmed Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias
title_short Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias
title_sort implantable defibrillators for secondary prevention of sudden cardiac death in cardiac surgery patients with perioperative ventricular arrhythmias
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4310357/
https://www.ncbi.nlm.nih.gov/pubmed/25146702
http://dx.doi.org/10.1161/JAHA.113.000686
work_keys_str_mv AT nagehmagedf implantabledefibrillatorsforsecondarypreventionofsuddencardiacdeathincardiacsurgerypatientswithperioperativeventriculararrhythmias
AT kimjohnj implantabledefibrillatorsforsecondarypreventionofsuddencardiacdeathincardiacsurgerypatientswithperioperativeventriculararrhythmias
AT chenliehong implantabledefibrillatorsforsecondarypreventionofsuddencardiacdeathincardiacsurgerypatientswithperioperativeventriculararrhythmias
AT yaojanisf implantabledefibrillatorsforsecondarypreventionofsuddencardiacdeathincardiacsurgerypatientswithperioperativeventriculararrhythmias