Cargando…
Automated Quantification of Myocardial Salvage in a Rat Model of Ischemia–Reperfusion Injury Using 3D High‐Resolution Magnetic Resonance Imaging (MRI)
BACKGROUND: Quantification of myocardial “area at risk” (AAR) and myocardial infarction (MI) zone is critical for assessing novel therapies targeting myocardial ischemia–reperfusion (IR) injury. Current “gold‐standard” methods perfuse the heart with Evan's Blue and stain with triphenyl tetrazol...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Blackwell Publishing Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4310382/ https://www.ncbi.nlm.nih.gov/pubmed/25146703 http://dx.doi.org/10.1161/JAHA.114.000956 |
_version_ | 1782354863026339840 |
---|---|
author | Grieve, Stuart M. Mazhar, Jawad Callaghan, Fraser Kok, Cindy Y. Tandy, Sarah Bhindi, Ravinay Figtree, Gemma A. |
author_facet | Grieve, Stuart M. Mazhar, Jawad Callaghan, Fraser Kok, Cindy Y. Tandy, Sarah Bhindi, Ravinay Figtree, Gemma A. |
author_sort | Grieve, Stuart M. |
collection | PubMed |
description | BACKGROUND: Quantification of myocardial “area at risk” (AAR) and myocardial infarction (MI) zone is critical for assessing novel therapies targeting myocardial ischemia–reperfusion (IR) injury. Current “gold‐standard” methods perfuse the heart with Evan's Blue and stain with triphenyl tetrazolium chloride (TTC), requiring manual slicing and analysis. We aimed to develop and validate a high‐resolution 3‐dimensional (3D) magnetic resonance imaging (MRI) method for quantifying MI and AAR. METHODS AND RESULTS: Forty‐eight hours after IR was induced, rats were anesthetized and gadopentetate dimeglumine was administered intravenously. After 10 minutes, the coronary artery was re‐ligated and a solution containing iron oxide microparticles and Evan's Blue was infused (for comparison). Hearts were harvested and transversally sectioned for TTC staining. Ex vivo MR images of slices were acquired on a 9.4‐T magnet. T2* data allowed visualization of AAR, with microparticle‐associated signal loss in perfused regions. T1 data demonstrated gadolinium retention in infarcted zones. Close correlation (r=0.92 to 0.94; P<0.05) of MRI and Evan's Blue/TTC measures for both AAR and MI was observed when the combined techniques were applied to the same heart slice. However, 3D MRI acquisition and analysis of whole heart reduced intra‐observer variability compared to assessment of isolated slices, and allowed automated segmentation and analysis, thus reducing interobserver variation. Anatomical resolution of 81 μm(3) was achieved (versus ≈2 mm with manual slicing). CONCLUSIONS: This novel, yet simple, MRI technique allows precise assessment of infarct and AAR zones. It removes the need for tissue slicing and provides opportunity for 3D digital analysis at high anatomical resolution in a streamlined manner accessible for all laboratories already performing IR experiments. |
format | Online Article Text |
id | pubmed-4310382 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Blackwell Publishing Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-43103822015-02-10 Automated Quantification of Myocardial Salvage in a Rat Model of Ischemia–Reperfusion Injury Using 3D High‐Resolution Magnetic Resonance Imaging (MRI) Grieve, Stuart M. Mazhar, Jawad Callaghan, Fraser Kok, Cindy Y. Tandy, Sarah Bhindi, Ravinay Figtree, Gemma A. J Am Heart Assoc Original Research BACKGROUND: Quantification of myocardial “area at risk” (AAR) and myocardial infarction (MI) zone is critical for assessing novel therapies targeting myocardial ischemia–reperfusion (IR) injury. Current “gold‐standard” methods perfuse the heart with Evan's Blue and stain with triphenyl tetrazolium chloride (TTC), requiring manual slicing and analysis. We aimed to develop and validate a high‐resolution 3‐dimensional (3D) magnetic resonance imaging (MRI) method for quantifying MI and AAR. METHODS AND RESULTS: Forty‐eight hours after IR was induced, rats were anesthetized and gadopentetate dimeglumine was administered intravenously. After 10 minutes, the coronary artery was re‐ligated and a solution containing iron oxide microparticles and Evan's Blue was infused (for comparison). Hearts were harvested and transversally sectioned for TTC staining. Ex vivo MR images of slices were acquired on a 9.4‐T magnet. T2* data allowed visualization of AAR, with microparticle‐associated signal loss in perfused regions. T1 data demonstrated gadolinium retention in infarcted zones. Close correlation (r=0.92 to 0.94; P<0.05) of MRI and Evan's Blue/TTC measures for both AAR and MI was observed when the combined techniques were applied to the same heart slice. However, 3D MRI acquisition and analysis of whole heart reduced intra‐observer variability compared to assessment of isolated slices, and allowed automated segmentation and analysis, thus reducing interobserver variation. Anatomical resolution of 81 μm(3) was achieved (versus ≈2 mm with manual slicing). CONCLUSIONS: This novel, yet simple, MRI technique allows precise assessment of infarct and AAR zones. It removes the need for tissue slicing and provides opportunity for 3D digital analysis at high anatomical resolution in a streamlined manner accessible for all laboratories already performing IR experiments. Blackwell Publishing Ltd 2014-06-27 /pmc/articles/PMC4310382/ /pubmed/25146703 http://dx.doi.org/10.1161/JAHA.114.000956 Text en © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial (http://creativecommons.org/licenses/by-nc/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Original Research Grieve, Stuart M. Mazhar, Jawad Callaghan, Fraser Kok, Cindy Y. Tandy, Sarah Bhindi, Ravinay Figtree, Gemma A. Automated Quantification of Myocardial Salvage in a Rat Model of Ischemia–Reperfusion Injury Using 3D High‐Resolution Magnetic Resonance Imaging (MRI) |
title | Automated Quantification of Myocardial Salvage in a Rat Model of Ischemia–Reperfusion Injury Using 3D High‐Resolution Magnetic Resonance Imaging (MRI) |
title_full | Automated Quantification of Myocardial Salvage in a Rat Model of Ischemia–Reperfusion Injury Using 3D High‐Resolution Magnetic Resonance Imaging (MRI) |
title_fullStr | Automated Quantification of Myocardial Salvage in a Rat Model of Ischemia–Reperfusion Injury Using 3D High‐Resolution Magnetic Resonance Imaging (MRI) |
title_full_unstemmed | Automated Quantification of Myocardial Salvage in a Rat Model of Ischemia–Reperfusion Injury Using 3D High‐Resolution Magnetic Resonance Imaging (MRI) |
title_short | Automated Quantification of Myocardial Salvage in a Rat Model of Ischemia–Reperfusion Injury Using 3D High‐Resolution Magnetic Resonance Imaging (MRI) |
title_sort | automated quantification of myocardial salvage in a rat model of ischemia–reperfusion injury using 3d high‐resolution magnetic resonance imaging (mri) |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4310382/ https://www.ncbi.nlm.nih.gov/pubmed/25146703 http://dx.doi.org/10.1161/JAHA.114.000956 |
work_keys_str_mv | AT grievestuartm automatedquantificationofmyocardialsalvageinaratmodelofischemiareperfusioninjuryusing3dhighresolutionmagneticresonanceimagingmri AT mazharjawad automatedquantificationofmyocardialsalvageinaratmodelofischemiareperfusioninjuryusing3dhighresolutionmagneticresonanceimagingmri AT callaghanfraser automatedquantificationofmyocardialsalvageinaratmodelofischemiareperfusioninjuryusing3dhighresolutionmagneticresonanceimagingmri AT kokcindyy automatedquantificationofmyocardialsalvageinaratmodelofischemiareperfusioninjuryusing3dhighresolutionmagneticresonanceimagingmri AT tandysarah automatedquantificationofmyocardialsalvageinaratmodelofischemiareperfusioninjuryusing3dhighresolutionmagneticresonanceimagingmri AT bhindiravinay automatedquantificationofmyocardialsalvageinaratmodelofischemiareperfusioninjuryusing3dhighresolutionmagneticresonanceimagingmri AT figtreegemmaa automatedquantificationofmyocardialsalvageinaratmodelofischemiareperfusioninjuryusing3dhighresolutionmagneticresonanceimagingmri |