Cargando…

Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry

A gas chromatography–mass spectrometry method was developed and validated for the simultaneous automated solid-phase extraction and quantification of cotinine and trans-3-hydroxycotinine in human urine. Good linearity was observed over the concentration ranges studied (R(2) > 0.99). The limit of...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiadmi, Fouad, Schlatter, Joël
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4314699/
https://www.ncbi.nlm.nih.gov/pubmed/24616054
http://dx.doi.org/10.1002/bmc.3159
_version_ 1782355352521539584
author Chiadmi, Fouad
Schlatter, Joël
author_facet Chiadmi, Fouad
Schlatter, Joël
author_sort Chiadmi, Fouad
collection PubMed
description A gas chromatography–mass spectrometry method was developed and validated for the simultaneous automated solid-phase extraction and quantification of cotinine and trans-3-hydroxycotinine in human urine. Good linearity was observed over the concentration ranges studied (R(2) > 0.99). The limit of quantification was 10 ng/mL for both analytes. The limits of detection were 0.06 ng/mL for cotinine (COT) and 0.02 ng/mL for trans-3-hydroxycotinine (OH-COT). Accuracy for COT ranged from 0.98 to 5.28% and the precision ranged from 1.24 to 8.78%. Accuracy for OH-COT ranged from −2.66 to 3.72% and the precision ranged from 3.15 to 7.07%. Mean recoveries for cotinine and trans-3-hydroxycotinine ranged from 77.7 to 89.1%, and from 75.4 to 90.2%, respectively. This analytical method for the simultaneous measurement of cotinine and trans-3-hydroxycotinine in urine will be used to monitor tobacco smoking in pregnant women and will permit the usefulness of trans-3-hydroxycotinine as a specific biomarker of tobacco exposure to be determined. © 2014 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd.
format Online
Article
Text
id pubmed-4314699
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Blackwell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-43146992015-02-04 Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry Chiadmi, Fouad Schlatter, Joël Biomed Chromatogr Rapid Communication A gas chromatography–mass spectrometry method was developed and validated for the simultaneous automated solid-phase extraction and quantification of cotinine and trans-3-hydroxycotinine in human urine. Good linearity was observed over the concentration ranges studied (R(2) > 0.99). The limit of quantification was 10 ng/mL for both analytes. The limits of detection were 0.06 ng/mL for cotinine (COT) and 0.02 ng/mL for trans-3-hydroxycotinine (OH-COT). Accuracy for COT ranged from 0.98 to 5.28% and the precision ranged from 1.24 to 8.78%. Accuracy for OH-COT ranged from −2.66 to 3.72% and the precision ranged from 3.15 to 7.07%. Mean recoveries for cotinine and trans-3-hydroxycotinine ranged from 77.7 to 89.1%, and from 75.4 to 90.2%, respectively. This analytical method for the simultaneous measurement of cotinine and trans-3-hydroxycotinine in urine will be used to monitor tobacco smoking in pregnant women and will permit the usefulness of trans-3-hydroxycotinine as a specific biomarker of tobacco exposure to be determined. © 2014 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd. Blackwell Publishing Ltd 2014-04 2014-02-24 /pmc/articles/PMC4314699/ /pubmed/24616054 http://dx.doi.org/10.1002/bmc.3159 Text en © 2014 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Rapid Communication
Chiadmi, Fouad
Schlatter, Joël
Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry
title Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry
title_full Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry
title_fullStr Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry
title_full_unstemmed Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry
title_short Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry
title_sort simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry
topic Rapid Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4314699/
https://www.ncbi.nlm.nih.gov/pubmed/24616054
http://dx.doi.org/10.1002/bmc.3159
work_keys_str_mv AT chiadmifouad simultaneousdeterminationofcotinineandtrans3hydroxycotinineinurinebyautomatedsolidphaseextractionusinggaschromatographymassspectrometry
AT schlatterjoel simultaneousdeterminationofcotinineandtrans3hydroxycotinineinurinebyautomatedsolidphaseextractionusinggaschromatographymassspectrometry