Cargando…
Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry
A gas chromatography–mass spectrometry method was developed and validated for the simultaneous automated solid-phase extraction and quantification of cotinine and trans-3-hydroxycotinine in human urine. Good linearity was observed over the concentration ranges studied (R(2) > 0.99). The limit of...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Blackwell Publishing Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4314699/ https://www.ncbi.nlm.nih.gov/pubmed/24616054 http://dx.doi.org/10.1002/bmc.3159 |
_version_ | 1782355352521539584 |
---|---|
author | Chiadmi, Fouad Schlatter, Joël |
author_facet | Chiadmi, Fouad Schlatter, Joël |
author_sort | Chiadmi, Fouad |
collection | PubMed |
description | A gas chromatography–mass spectrometry method was developed and validated for the simultaneous automated solid-phase extraction and quantification of cotinine and trans-3-hydroxycotinine in human urine. Good linearity was observed over the concentration ranges studied (R(2) > 0.99). The limit of quantification was 10 ng/mL for both analytes. The limits of detection were 0.06 ng/mL for cotinine (COT) and 0.02 ng/mL for trans-3-hydroxycotinine (OH-COT). Accuracy for COT ranged from 0.98 to 5.28% and the precision ranged from 1.24 to 8.78%. Accuracy for OH-COT ranged from −2.66 to 3.72% and the precision ranged from 3.15 to 7.07%. Mean recoveries for cotinine and trans-3-hydroxycotinine ranged from 77.7 to 89.1%, and from 75.4 to 90.2%, respectively. This analytical method for the simultaneous measurement of cotinine and trans-3-hydroxycotinine in urine will be used to monitor tobacco smoking in pregnant women and will permit the usefulness of trans-3-hydroxycotinine as a specific biomarker of tobacco exposure to be determined. © 2014 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd. |
format | Online Article Text |
id | pubmed-4314699 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Blackwell Publishing Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-43146992015-02-04 Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry Chiadmi, Fouad Schlatter, Joël Biomed Chromatogr Rapid Communication A gas chromatography–mass spectrometry method was developed and validated for the simultaneous automated solid-phase extraction and quantification of cotinine and trans-3-hydroxycotinine in human urine. Good linearity was observed over the concentration ranges studied (R(2) > 0.99). The limit of quantification was 10 ng/mL for both analytes. The limits of detection were 0.06 ng/mL for cotinine (COT) and 0.02 ng/mL for trans-3-hydroxycotinine (OH-COT). Accuracy for COT ranged from 0.98 to 5.28% and the precision ranged from 1.24 to 8.78%. Accuracy for OH-COT ranged from −2.66 to 3.72% and the precision ranged from 3.15 to 7.07%. Mean recoveries for cotinine and trans-3-hydroxycotinine ranged from 77.7 to 89.1%, and from 75.4 to 90.2%, respectively. This analytical method for the simultaneous measurement of cotinine and trans-3-hydroxycotinine in urine will be used to monitor tobacco smoking in pregnant women and will permit the usefulness of trans-3-hydroxycotinine as a specific biomarker of tobacco exposure to be determined. © 2014 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd. Blackwell Publishing Ltd 2014-04 2014-02-24 /pmc/articles/PMC4314699/ /pubmed/24616054 http://dx.doi.org/10.1002/bmc.3159 Text en © 2014 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Rapid Communication Chiadmi, Fouad Schlatter, Joël Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry |
title | Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry |
title_full | Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry |
title_fullStr | Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry |
title_full_unstemmed | Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry |
title_short | Simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry |
title_sort | simultaneous determination of cotinine and trans-3-hydroxycotinine in urine by automated solid-phase extraction using gas chromatography–mass spectrometry |
topic | Rapid Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4314699/ https://www.ncbi.nlm.nih.gov/pubmed/24616054 http://dx.doi.org/10.1002/bmc.3159 |
work_keys_str_mv | AT chiadmifouad simultaneousdeterminationofcotinineandtrans3hydroxycotinineinurinebyautomatedsolidphaseextractionusinggaschromatographymassspectrometry AT schlatterjoel simultaneousdeterminationofcotinineandtrans3hydroxycotinineinurinebyautomatedsolidphaseextractionusinggaschromatographymassspectrometry |