Cargando…

Osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact

OBJECTIVES: Screw fixation and fragment anchoring in osteoporotic bones is often difficult. Problems like the cut out phenomenon and implant migration in osteoporotic bones have been reported. One possibility of improving the anchoring force of screws is augmentation of the screw. Cement-augmented s...

Descripción completa

Detalles Bibliográficos
Autores principales: Neumann, Hanjo, Breer, Stefan, Reimers, Nils, Kasch, Richard, Schulz, Arndt-Peter, Kienast, Benjamin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4314756/
https://www.ncbi.nlm.nih.gov/pubmed/25628015
http://dx.doi.org/10.1186/s13018-015-0156-1
_version_ 1782355361299169280
author Neumann, Hanjo
Breer, Stefan
Reimers, Nils
Kasch, Richard
Schulz, Arndt-Peter
Kienast, Benjamin
author_facet Neumann, Hanjo
Breer, Stefan
Reimers, Nils
Kasch, Richard
Schulz, Arndt-Peter
Kienast, Benjamin
author_sort Neumann, Hanjo
collection PubMed
description OBJECTIVES: Screw fixation and fragment anchoring in osteoporotic bones is often difficult. Problems like the cut out phenomenon and implant migration in osteoporotic bones have been reported. One possibility of improving the anchoring force of screws is augmentation of the screw. Cement-augmented screws in spinal surgery could exhibit a better anchoring in osteoporotic bones. METHODS: The purpose of this study was to examine the effect of screw augmentation using a resorbable polymer. Ultrasound-activated biodegradable pins were used for the purpose of a resorbable augmentation technique. Cannulated screws were inserted into the femur of 12 sheep and augmented by an ultrasound-activated polylactic acid (PLDLA) pin. In a paired approach, four screws were implanted in each animal: 2× a 10-mm thread and 2× a 20-mm thread, both of which were augmented with polymer. Both screws, named A and B, were also applied without augmentation (control group) and implanted into the contralateral hind limb. After 4, 8, and 12 weeks, the sheep were euthanized and a macroscopical and histological examination followed. RESULTS: The polymer spread well out of the screws into the cancellous lacunae. Around the polymer, the peripheral bone showed signs of healthy and active bone tissue. No evidence of inflammation or infection was observed. The boneto-implant contact was significantly higher in the augmented screws. Biocompatibility was proven in histopathological examination. After 12 weeks, no pathological changes were found. CONCLUSION: Ultrasound-activated polymer augmentation of cannulated screws may improve the anchoring in osteoporotic bone. ARTICLE FOCUS: Can screw augmentation using a resorbable polymer improve the bone-to-implant contact in case of screw osteosynthesis? Is there any effect on the surrounding tissue by the induced temperature and liquefied polymer? Can biocompatibility be proven by this new osteosynthesis? KEY MESSAGES: Screw augmentation by ultrasound-activated biopolymer leads to a significant higher bone-to-implant contact than pure screw osteosynthesis. No tissue damage could be observed by the application of the SonicFusion™. STRENGTH AND LIMITATIONS OF THIS STUDY: The ovine in vivo study concept can simulate physiological conditions. First examination of screw augmentation by ultrasound-activated biopolymer. No biomechanical testing of the higher bone-to-implant contact by now.
format Online
Article
Text
id pubmed-4314756
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-43147562015-02-04 Osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact Neumann, Hanjo Breer, Stefan Reimers, Nils Kasch, Richard Schulz, Arndt-Peter Kienast, Benjamin J Orthop Surg Res Research Article OBJECTIVES: Screw fixation and fragment anchoring in osteoporotic bones is often difficult. Problems like the cut out phenomenon and implant migration in osteoporotic bones have been reported. One possibility of improving the anchoring force of screws is augmentation of the screw. Cement-augmented screws in spinal surgery could exhibit a better anchoring in osteoporotic bones. METHODS: The purpose of this study was to examine the effect of screw augmentation using a resorbable polymer. Ultrasound-activated biodegradable pins were used for the purpose of a resorbable augmentation technique. Cannulated screws were inserted into the femur of 12 sheep and augmented by an ultrasound-activated polylactic acid (PLDLA) pin. In a paired approach, four screws were implanted in each animal: 2× a 10-mm thread and 2× a 20-mm thread, both of which were augmented with polymer. Both screws, named A and B, were also applied without augmentation (control group) and implanted into the contralateral hind limb. After 4, 8, and 12 weeks, the sheep were euthanized and a macroscopical and histological examination followed. RESULTS: The polymer spread well out of the screws into the cancellous lacunae. Around the polymer, the peripheral bone showed signs of healthy and active bone tissue. No evidence of inflammation or infection was observed. The boneto-implant contact was significantly higher in the augmented screws. Biocompatibility was proven in histopathological examination. After 12 weeks, no pathological changes were found. CONCLUSION: Ultrasound-activated polymer augmentation of cannulated screws may improve the anchoring in osteoporotic bone. ARTICLE FOCUS: Can screw augmentation using a resorbable polymer improve the bone-to-implant contact in case of screw osteosynthesis? Is there any effect on the surrounding tissue by the induced temperature and liquefied polymer? Can biocompatibility be proven by this new osteosynthesis? KEY MESSAGES: Screw augmentation by ultrasound-activated biopolymer leads to a significant higher bone-to-implant contact than pure screw osteosynthesis. No tissue damage could be observed by the application of the SonicFusion™. STRENGTH AND LIMITATIONS OF THIS STUDY: The ovine in vivo study concept can simulate physiological conditions. First examination of screw augmentation by ultrasound-activated biopolymer. No biomechanical testing of the higher bone-to-implant contact by now. BioMed Central 2015-01-28 /pmc/articles/PMC4314756/ /pubmed/25628015 http://dx.doi.org/10.1186/s13018-015-0156-1 Text en © Neumann et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Neumann, Hanjo
Breer, Stefan
Reimers, Nils
Kasch, Richard
Schulz, Arndt-Peter
Kienast, Benjamin
Osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact
title Osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact
title_full Osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact
title_fullStr Osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact
title_full_unstemmed Osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact
title_short Osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact
title_sort osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4314756/
https://www.ncbi.nlm.nih.gov/pubmed/25628015
http://dx.doi.org/10.1186/s13018-015-0156-1
work_keys_str_mv AT neumannhanjo osteosynthesisscrewaugmentationbyultrasoundactivatedbiopolymeranovineinvivostudyassessingbiocompatibilityandbonetoimplantcontact
AT breerstefan osteosynthesisscrewaugmentationbyultrasoundactivatedbiopolymeranovineinvivostudyassessingbiocompatibilityandbonetoimplantcontact
AT reimersnils osteosynthesisscrewaugmentationbyultrasoundactivatedbiopolymeranovineinvivostudyassessingbiocompatibilityandbonetoimplantcontact
AT kaschrichard osteosynthesisscrewaugmentationbyultrasoundactivatedbiopolymeranovineinvivostudyassessingbiocompatibilityandbonetoimplantcontact
AT schulzarndtpeter osteosynthesisscrewaugmentationbyultrasoundactivatedbiopolymeranovineinvivostudyassessingbiocompatibilityandbonetoimplantcontact
AT kienastbenjamin osteosynthesisscrewaugmentationbyultrasoundactivatedbiopolymeranovineinvivostudyassessingbiocompatibilityandbonetoimplantcontact