Cargando…
Evaluation of the cytotoxicity of fiber reinforced composite bonded retainers and flexible spiral wires retainers in simulated high and low cariogenic environments
OBJECTIVES: The aim of this study was to evaluate the cytotoxic effects of fiber reinforced composite bonded retainers in comparison with flexible spiral wires (FSWs) under high and low cariogenic-simulated environments using human oral fibroblasts. MATERIALS AND METHODS: Four types of bonded retain...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4314835/ https://www.ncbi.nlm.nih.gov/pubmed/25657987 http://dx.doi.org/10.4103/2278-0203.149610 |
_version_ | 1782355376825434112 |
---|---|
author | Jahanbin, Arezoo Shahabi, Mostafa Ahrari, Farzaneh Bozorgnia, Yasaman Shajiei, Arezoo Shafaee, Hooman Afshari, Jalil Tavakkol |
author_facet | Jahanbin, Arezoo Shahabi, Mostafa Ahrari, Farzaneh Bozorgnia, Yasaman Shajiei, Arezoo Shafaee, Hooman Afshari, Jalil Tavakkol |
author_sort | Jahanbin, Arezoo |
collection | PubMed |
description | OBJECTIVES: The aim of this study was to evaluate the cytotoxic effects of fiber reinforced composite bonded retainers in comparison with flexible spiral wires (FSWs) under high and low cariogenic-simulated environments using human oral fibroblasts. MATERIALS AND METHODS: Four types of bonded retainers were evaluated: (1) reinforced with glass fibers: Interlig (Angelus), (2) reinforced with polyethylene fibers: Connect (Kerr), (3) reinforced with quartz fibers: Quartz Splint UD (RTD), and (4) FSW. Twenty specimens of each sample group were prepared with the same surface area and halved. Next, half of them were placed in a high cariogenic environment 60 min in 10% lactic acid 3 times a day and remained in Fusayama Meyer artificial saliva for the rest of the day) and the other half were placed in a low cariogenic environment 20 min in 10% lactic acid 3 times a day and remained in Fusayama Meyer artificial saliva for the rest of the day) for 1, 7 and 30 days. Cell viability was assessed by MTT assay. Data were analyzed using SPSS software (α =0.05). RESULTS: During the 1(st) month, cytotoxicity reduced gradually. In the low cariogenic-simulated environment, the cytotoxicity of all of the groups were reported to be mild at day 30 and the difference between them was significant (P = 0.016). In the same period in the high cariogenic-simulated environment, the cytotoxicity of Connect and Quartz Splint was mild, and they had lower cytotoxicity than the other groups. Meanwhile, Interlig had moderate (52%) and FSW had severe cytotoxicity (22%) and the difference between the groups was also significant (P = 0.000). CONCLUSIONS: FSW retainers are not recommended in those at high-risk for dental caries. However, in those at low-risk, there is no difference from the standpoint of cytotoxicity. |
format | Online Article Text |
id | pubmed-4314835 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-43148352015-02-05 Evaluation of the cytotoxicity of fiber reinforced composite bonded retainers and flexible spiral wires retainers in simulated high and low cariogenic environments Jahanbin, Arezoo Shahabi, Mostafa Ahrari, Farzaneh Bozorgnia, Yasaman Shajiei, Arezoo Shafaee, Hooman Afshari, Jalil Tavakkol J Orthod Sci Original Article OBJECTIVES: The aim of this study was to evaluate the cytotoxic effects of fiber reinforced composite bonded retainers in comparison with flexible spiral wires (FSWs) under high and low cariogenic-simulated environments using human oral fibroblasts. MATERIALS AND METHODS: Four types of bonded retainers were evaluated: (1) reinforced with glass fibers: Interlig (Angelus), (2) reinforced with polyethylene fibers: Connect (Kerr), (3) reinforced with quartz fibers: Quartz Splint UD (RTD), and (4) FSW. Twenty specimens of each sample group were prepared with the same surface area and halved. Next, half of them were placed in a high cariogenic environment 60 min in 10% lactic acid 3 times a day and remained in Fusayama Meyer artificial saliva for the rest of the day) and the other half were placed in a low cariogenic environment 20 min in 10% lactic acid 3 times a day and remained in Fusayama Meyer artificial saliva for the rest of the day) for 1, 7 and 30 days. Cell viability was assessed by MTT assay. Data were analyzed using SPSS software (α =0.05). RESULTS: During the 1(st) month, cytotoxicity reduced gradually. In the low cariogenic-simulated environment, the cytotoxicity of all of the groups were reported to be mild at day 30 and the difference between them was significant (P = 0.016). In the same period in the high cariogenic-simulated environment, the cytotoxicity of Connect and Quartz Splint was mild, and they had lower cytotoxicity than the other groups. Meanwhile, Interlig had moderate (52%) and FSW had severe cytotoxicity (22%) and the difference between the groups was also significant (P = 0.000). CONCLUSIONS: FSW retainers are not recommended in those at high-risk for dental caries. However, in those at low-risk, there is no difference from the standpoint of cytotoxicity. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4314835/ /pubmed/25657987 http://dx.doi.org/10.4103/2278-0203.149610 Text en Copyright: © Journal of Orthodontic Science http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Jahanbin, Arezoo Shahabi, Mostafa Ahrari, Farzaneh Bozorgnia, Yasaman Shajiei, Arezoo Shafaee, Hooman Afshari, Jalil Tavakkol Evaluation of the cytotoxicity of fiber reinforced composite bonded retainers and flexible spiral wires retainers in simulated high and low cariogenic environments |
title | Evaluation of the cytotoxicity of fiber reinforced composite bonded retainers and flexible spiral wires retainers in simulated high and low cariogenic environments |
title_full | Evaluation of the cytotoxicity of fiber reinforced composite bonded retainers and flexible spiral wires retainers in simulated high and low cariogenic environments |
title_fullStr | Evaluation of the cytotoxicity of fiber reinforced composite bonded retainers and flexible spiral wires retainers in simulated high and low cariogenic environments |
title_full_unstemmed | Evaluation of the cytotoxicity of fiber reinforced composite bonded retainers and flexible spiral wires retainers in simulated high and low cariogenic environments |
title_short | Evaluation of the cytotoxicity of fiber reinforced composite bonded retainers and flexible spiral wires retainers in simulated high and low cariogenic environments |
title_sort | evaluation of the cytotoxicity of fiber reinforced composite bonded retainers and flexible spiral wires retainers in simulated high and low cariogenic environments |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4314835/ https://www.ncbi.nlm.nih.gov/pubmed/25657987 http://dx.doi.org/10.4103/2278-0203.149610 |
work_keys_str_mv | AT jahanbinarezoo evaluationofthecytotoxicityoffiberreinforcedcompositebondedretainersandflexiblespiralwiresretainersinsimulatedhighandlowcariogenicenvironments AT shahabimostafa evaluationofthecytotoxicityoffiberreinforcedcompositebondedretainersandflexiblespiralwiresretainersinsimulatedhighandlowcariogenicenvironments AT ahrarifarzaneh evaluationofthecytotoxicityoffiberreinforcedcompositebondedretainersandflexiblespiralwiresretainersinsimulatedhighandlowcariogenicenvironments AT bozorgniayasaman evaluationofthecytotoxicityoffiberreinforcedcompositebondedretainersandflexiblespiralwiresretainersinsimulatedhighandlowcariogenicenvironments AT shajieiarezoo evaluationofthecytotoxicityoffiberreinforcedcompositebondedretainersandflexiblespiralwiresretainersinsimulatedhighandlowcariogenicenvironments AT shafaeehooman evaluationofthecytotoxicityoffiberreinforcedcompositebondedretainersandflexiblespiralwiresretainersinsimulatedhighandlowcariogenicenvironments AT afsharijaliltavakkol evaluationofthecytotoxicityoffiberreinforcedcompositebondedretainersandflexiblespiralwiresretainersinsimulatedhighandlowcariogenicenvironments |