Cargando…

Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions

OBJECT: A new method for 3D localization of N fiducial markers from 1D projections is presented and analysed. It applies to semi-active markers and active markers using a single receiver channel. MATERIALS AND METHODS: The novel algorithm computes candidate points using peaks in three optimally sele...

Descripción completa

Detalles Bibliográficos
Autores principales: Galassi, Francesca, Brujic, Djordje, Rea, Marc, Lambert, Nicholas, Desouza, Nandita, Ristic, Mihailo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4315881/
https://www.ncbi.nlm.nih.gov/pubmed/24802620
http://dx.doi.org/10.1007/s10334-014-0446-3
_version_ 1782355524592861184
author Galassi, Francesca
Brujic, Djordje
Rea, Marc
Lambert, Nicholas
Desouza, Nandita
Ristic, Mihailo
author_facet Galassi, Francesca
Brujic, Djordje
Rea, Marc
Lambert, Nicholas
Desouza, Nandita
Ristic, Mihailo
author_sort Galassi, Francesca
collection PubMed
description OBJECT: A new method for 3D localization of N fiducial markers from 1D projections is presented and analysed. It applies to semi-active markers and active markers using a single receiver channel. MATERIALS AND METHODS: The novel algorithm computes candidate points using peaks in three optimally selected projections and removes fictitious points by verifying detected peaks in additional projections. Computational complexity was significantly reduced by avoiding cluster analysis, while higher accuracy was achieved by using optimal projections and by applying Gaussian interpolation in peak detection. Computational time, accuracy and robustness were analysed through Monte Carlo simulations and experiments. The method was employed in a prototype MRI guided prostate biopsy system and used in preclinical experiments. RESULTS: The computational time for 6 markers was better than 2 ms, an improvement of up to 100 times, compared to the method by Flask et al. (J Magn Reson Imaging 14(5):617–627, 2001). Experimental maximum localization error was lower than 0.3 mm; standard deviation was 0.06 mm. Targeting error was about 1 mm. Tracking update rate was about 10 Hz. CONCLUSION: The proposed method is particularly suitable in systems requiring any of the following: high frame rate, tracking of three or more markers, data filtering or interleaving.
format Online
Article
Text
id pubmed-4315881
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-43158812015-02-06 Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions Galassi, Francesca Brujic, Djordje Rea, Marc Lambert, Nicholas Desouza, Nandita Ristic, Mihailo MAGMA Research Article OBJECT: A new method for 3D localization of N fiducial markers from 1D projections is presented and analysed. It applies to semi-active markers and active markers using a single receiver channel. MATERIALS AND METHODS: The novel algorithm computes candidate points using peaks in three optimally selected projections and removes fictitious points by verifying detected peaks in additional projections. Computational complexity was significantly reduced by avoiding cluster analysis, while higher accuracy was achieved by using optimal projections and by applying Gaussian interpolation in peak detection. Computational time, accuracy and robustness were analysed through Monte Carlo simulations and experiments. The method was employed in a prototype MRI guided prostate biopsy system and used in preclinical experiments. RESULTS: The computational time for 6 markers was better than 2 ms, an improvement of up to 100 times, compared to the method by Flask et al. (J Magn Reson Imaging 14(5):617–627, 2001). Experimental maximum localization error was lower than 0.3 mm; standard deviation was 0.06 mm. Targeting error was about 1 mm. Tracking update rate was about 10 Hz. CONCLUSION: The proposed method is particularly suitable in systems requiring any of the following: high frame rate, tracking of three or more markers, data filtering or interleaving. Springer Berlin Heidelberg 2014-05-07 2015 /pmc/articles/PMC4315881/ /pubmed/24802620 http://dx.doi.org/10.1007/s10334-014-0446-3 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Research Article
Galassi, Francesca
Brujic, Djordje
Rea, Marc
Lambert, Nicholas
Desouza, Nandita
Ristic, Mihailo
Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions
title Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions
title_full Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions
title_fullStr Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions
title_full_unstemmed Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions
title_short Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions
title_sort fast and accurate localization of multiple rf markers for tracking in mri-guided interventions
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4315881/
https://www.ncbi.nlm.nih.gov/pubmed/24802620
http://dx.doi.org/10.1007/s10334-014-0446-3
work_keys_str_mv AT galassifrancesca fastandaccuratelocalizationofmultiplerfmarkersfortrackinginmriguidedinterventions
AT brujicdjordje fastandaccuratelocalizationofmultiplerfmarkersfortrackinginmriguidedinterventions
AT reamarc fastandaccuratelocalizationofmultiplerfmarkersfortrackinginmriguidedinterventions
AT lambertnicholas fastandaccuratelocalizationofmultiplerfmarkersfortrackinginmriguidedinterventions
AT desouzanandita fastandaccuratelocalizationofmultiplerfmarkersfortrackinginmriguidedinterventions
AT risticmihailo fastandaccuratelocalizationofmultiplerfmarkersfortrackinginmriguidedinterventions