Cargando…

A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory

BACKGROUND: Recent guidelines recommended by ESC, ACC, AHA, and WHF concerning biomarkers of myocardial necrosis also apply to the work of clinical laboratories. Methodological modification for tests used in determining cardiac biomarkers reduced the time of the analytical procedure to 9 min (STAT v...

Descripción completa

Detalles Bibliográficos
Autores principales: Wlazeł, Rafał Nikodem, Kasprzak, Jarosław, Paradowski, Marek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4318227/
https://www.ncbi.nlm.nih.gov/pubmed/25629263
http://dx.doi.org/10.12659/MSM.892033
_version_ 1782355827500253184
author Wlazeł, Rafał Nikodem
Kasprzak, Jarosław
Paradowski, Marek
author_facet Wlazeł, Rafał Nikodem
Kasprzak, Jarosław
Paradowski, Marek
author_sort Wlazeł, Rafał Nikodem
collection PubMed
description BACKGROUND: Recent guidelines recommended by ESC, ACC, AHA, and WHF concerning biomarkers of myocardial necrosis also apply to the work of clinical laboratories. Methodological modification for tests used in determining cardiac biomarkers reduced the time of the analytical procedure to 9 min (STAT version of the tests). We decided to determine and compare analytical quality of the tests in standard and STAT versions for determining serum level: troponin T, MB isoenzyme of creatine kinase, and myoglobin, as well as to verify whether the TnThs STAT test meets the following requirements: CV <10% at the level close to diagnostic, equal to the 99(th) percentile of reference population, and turnaround time <60 min. MATERIAL/METHODS: We evaluated real precision and accuracy for both standard and STAT versions of tests as well as the correlation of results of physiological and pathological levels. Additionally, observations of turnaround time were made. RESULTS: Calculated values of total errors did not exceed the recommended acceptable total error (<20%). Comparable precision of the 2 measurement methods (CV=3.07%) was obtained. A strong correlation (R>0.99) between both variants of tests for all the parameters was confirmed. Thanks to the application of new reagent kit, the percentage of results with turnaround time <60 min increased from 40% to 75% (n=115; p=0.000008). CONCLUSIONS: The new generation of STAT cardiac biomarkers has high analytical quality and meets international precision requirements. It guarantees high analytical and clinical reliability of results. Use of the STAT version of biomarkers contributes to a significant decrease in turnaround time and allows obtaining a good result of an analysis.
format Online
Article
Text
id pubmed-4318227
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-43182272015-02-11 A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory Wlazeł, Rafał Nikodem Kasprzak, Jarosław Paradowski, Marek Med Sci Monit Product Investigations BACKGROUND: Recent guidelines recommended by ESC, ACC, AHA, and WHF concerning biomarkers of myocardial necrosis also apply to the work of clinical laboratories. Methodological modification for tests used in determining cardiac biomarkers reduced the time of the analytical procedure to 9 min (STAT version of the tests). We decided to determine and compare analytical quality of the tests in standard and STAT versions for determining serum level: troponin T, MB isoenzyme of creatine kinase, and myoglobin, as well as to verify whether the TnThs STAT test meets the following requirements: CV <10% at the level close to diagnostic, equal to the 99(th) percentile of reference population, and turnaround time <60 min. MATERIAL/METHODS: We evaluated real precision and accuracy for both standard and STAT versions of tests as well as the correlation of results of physiological and pathological levels. Additionally, observations of turnaround time were made. RESULTS: Calculated values of total errors did not exceed the recommended acceptable total error (<20%). Comparable precision of the 2 measurement methods (CV=3.07%) was obtained. A strong correlation (R>0.99) between both variants of tests for all the parameters was confirmed. Thanks to the application of new reagent kit, the percentage of results with turnaround time <60 min increased from 40% to 75% (n=115; p=0.000008). CONCLUSIONS: The new generation of STAT cardiac biomarkers has high analytical quality and meets international precision requirements. It guarantees high analytical and clinical reliability of results. Use of the STAT version of biomarkers contributes to a significant decrease in turnaround time and allows obtaining a good result of an analysis. International Scientific Literature, Inc. 2015-01-28 /pmc/articles/PMC4318227/ /pubmed/25629263 http://dx.doi.org/10.12659/MSM.892033 Text en © Med Sci Monit, 2015 This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License
spellingShingle Product Investigations
Wlazeł, Rafał Nikodem
Kasprzak, Jarosław
Paradowski, Marek
A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory
title A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory
title_full A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory
title_fullStr A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory
title_full_unstemmed A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory
title_short A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory
title_sort new generation of biomarkers tests of myocardial necrosis: the real quality a physician can get from the laboratory
topic Product Investigations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4318227/
https://www.ncbi.nlm.nih.gov/pubmed/25629263
http://dx.doi.org/10.12659/MSM.892033
work_keys_str_mv AT wlazełrafałnikodem anewgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory
AT kasprzakjarosław anewgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory
AT paradowskimarek anewgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory
AT wlazełrafałnikodem newgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory
AT kasprzakjarosław newgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory
AT paradowskimarek newgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory