Cargando…
A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory
BACKGROUND: Recent guidelines recommended by ESC, ACC, AHA, and WHF concerning biomarkers of myocardial necrosis also apply to the work of clinical laboratories. Methodological modification for tests used in determining cardiac biomarkers reduced the time of the analytical procedure to 9 min (STAT v...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4318227/ https://www.ncbi.nlm.nih.gov/pubmed/25629263 http://dx.doi.org/10.12659/MSM.892033 |
_version_ | 1782355827500253184 |
---|---|
author | Wlazeł, Rafał Nikodem Kasprzak, Jarosław Paradowski, Marek |
author_facet | Wlazeł, Rafał Nikodem Kasprzak, Jarosław Paradowski, Marek |
author_sort | Wlazeł, Rafał Nikodem |
collection | PubMed |
description | BACKGROUND: Recent guidelines recommended by ESC, ACC, AHA, and WHF concerning biomarkers of myocardial necrosis also apply to the work of clinical laboratories. Methodological modification for tests used in determining cardiac biomarkers reduced the time of the analytical procedure to 9 min (STAT version of the tests). We decided to determine and compare analytical quality of the tests in standard and STAT versions for determining serum level: troponin T, MB isoenzyme of creatine kinase, and myoglobin, as well as to verify whether the TnThs STAT test meets the following requirements: CV <10% at the level close to diagnostic, equal to the 99(th) percentile of reference population, and turnaround time <60 min. MATERIAL/METHODS: We evaluated real precision and accuracy for both standard and STAT versions of tests as well as the correlation of results of physiological and pathological levels. Additionally, observations of turnaround time were made. RESULTS: Calculated values of total errors did not exceed the recommended acceptable total error (<20%). Comparable precision of the 2 measurement methods (CV=3.07%) was obtained. A strong correlation (R>0.99) between both variants of tests for all the parameters was confirmed. Thanks to the application of new reagent kit, the percentage of results with turnaround time <60 min increased from 40% to 75% (n=115; p=0.000008). CONCLUSIONS: The new generation of STAT cardiac biomarkers has high analytical quality and meets international precision requirements. It guarantees high analytical and clinical reliability of results. Use of the STAT version of biomarkers contributes to a significant decrease in turnaround time and allows obtaining a good result of an analysis. |
format | Online Article Text |
id | pubmed-4318227 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-43182272015-02-11 A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory Wlazeł, Rafał Nikodem Kasprzak, Jarosław Paradowski, Marek Med Sci Monit Product Investigations BACKGROUND: Recent guidelines recommended by ESC, ACC, AHA, and WHF concerning biomarkers of myocardial necrosis also apply to the work of clinical laboratories. Methodological modification for tests used in determining cardiac biomarkers reduced the time of the analytical procedure to 9 min (STAT version of the tests). We decided to determine and compare analytical quality of the tests in standard and STAT versions for determining serum level: troponin T, MB isoenzyme of creatine kinase, and myoglobin, as well as to verify whether the TnThs STAT test meets the following requirements: CV <10% at the level close to diagnostic, equal to the 99(th) percentile of reference population, and turnaround time <60 min. MATERIAL/METHODS: We evaluated real precision and accuracy for both standard and STAT versions of tests as well as the correlation of results of physiological and pathological levels. Additionally, observations of turnaround time were made. RESULTS: Calculated values of total errors did not exceed the recommended acceptable total error (<20%). Comparable precision of the 2 measurement methods (CV=3.07%) was obtained. A strong correlation (R>0.99) between both variants of tests for all the parameters was confirmed. Thanks to the application of new reagent kit, the percentage of results with turnaround time <60 min increased from 40% to 75% (n=115; p=0.000008). CONCLUSIONS: The new generation of STAT cardiac biomarkers has high analytical quality and meets international precision requirements. It guarantees high analytical and clinical reliability of results. Use of the STAT version of biomarkers contributes to a significant decrease in turnaround time and allows obtaining a good result of an analysis. International Scientific Literature, Inc. 2015-01-28 /pmc/articles/PMC4318227/ /pubmed/25629263 http://dx.doi.org/10.12659/MSM.892033 Text en © Med Sci Monit, 2015 This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License |
spellingShingle | Product Investigations Wlazeł, Rafał Nikodem Kasprzak, Jarosław Paradowski, Marek A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory |
title | A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory |
title_full | A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory |
title_fullStr | A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory |
title_full_unstemmed | A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory |
title_short | A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory |
title_sort | new generation of biomarkers tests of myocardial necrosis: the real quality a physician can get from the laboratory |
topic | Product Investigations |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4318227/ https://www.ncbi.nlm.nih.gov/pubmed/25629263 http://dx.doi.org/10.12659/MSM.892033 |
work_keys_str_mv | AT wlazełrafałnikodem anewgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory AT kasprzakjarosław anewgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory AT paradowskimarek anewgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory AT wlazełrafałnikodem newgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory AT kasprzakjarosław newgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory AT paradowskimarek newgenerationofbiomarkerstestsofmyocardialnecrosistherealqualityaphysiciancangetfromthelaboratory |