Cargando…

Molecular detection of human Plasmodium species in Sabah using PlasmoNex™ multiplex PCR and hydrolysis probes real-time PCR

BACKGROUND: Malaria is a vector borne-parasitic disease transmitted through the bite of the infective female Anopheles mosquitoes. Five Plasmodium species have been recognized by World Health Organization (WHO) as the causative agents of human malaria. Generally, microscopic examination is the gold...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Ping Chin, Chong, Eric Tzyy Jiann, Anderios, Fread, AL Lim, Yvonne, Chew, Ching Hoong, Chua, Kek Heng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4318434/
https://www.ncbi.nlm.nih.gov/pubmed/25651852
http://dx.doi.org/10.1186/s12936-015-0542-5
_version_ 1782355848528396288
author Lee, Ping Chin
Chong, Eric Tzyy Jiann
Anderios, Fread
AL Lim, Yvonne
Chew, Ching Hoong
Chua, Kek Heng
author_facet Lee, Ping Chin
Chong, Eric Tzyy Jiann
Anderios, Fread
AL Lim, Yvonne
Chew, Ching Hoong
Chua, Kek Heng
author_sort Lee, Ping Chin
collection PubMed
description BACKGROUND: Malaria is a vector borne-parasitic disease transmitted through the bite of the infective female Anopheles mosquitoes. Five Plasmodium species have been recognized by World Health Organization (WHO) as the causative agents of human malaria. Generally, microscopic examination is the gold standard for routine malaria diagnosis. However, molecular PCR assays in many cases have shown improvement on the sensitivity and specificity over microscopic or other immunochromatographic assays. METHODS: The present study attempts to screen 207 suspected malaria samples from patients seeking treatment in clinics around Sabah state, Malaysia, using two panels of multiplex PCRs, conventional PCR system (PlasmoNex™) and real-time PCR based on hydrolysis probe technology. Discordance results between two PCR assays were further confirmed by sequencing using 18S ssu rRNA species-specific primers. RESULTS: Of the 207 malaria samples, Plasmodium knowlesi (73.4% vs 72.0%) was the most prevalent species based on two PCR assays, followed by Plasmodium falciparum (15.9% vs 17.9%), and Plasmodium vivax (9.7% vs 7.7%), respectively. Neither Plasmodium malariae nor Plasmodium ovale was detected in this study. Nine discrepant species identification based on both the PCR assays were further confirmed through DNA sequencing. Species-specific real-time PCR only accurately diagnosed 198 of 207 (95.7%) malaria samples up to species level in contrast to PlasmoNex™ assay which had 100% sensitivity and specificity based on sequencing results. CONCLUSIONS: Multiplex PCR accelerate the speed in the diagnosis of malaria. The PlasmoNex™ PCR assay seems to be more accurate than real-time PCR in the speciation of all five human malaria parasites. The present study also showed a significant increase of the potential fatal P. knowlesi infection in Sabah state as revealed by molecular PCR assays.
format Online
Article
Text
id pubmed-4318434
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-43184342015-02-06 Molecular detection of human Plasmodium species in Sabah using PlasmoNex™ multiplex PCR and hydrolysis probes real-time PCR Lee, Ping Chin Chong, Eric Tzyy Jiann Anderios, Fread AL Lim, Yvonne Chew, Ching Hoong Chua, Kek Heng Malar J Research BACKGROUND: Malaria is a vector borne-parasitic disease transmitted through the bite of the infective female Anopheles mosquitoes. Five Plasmodium species have been recognized by World Health Organization (WHO) as the causative agents of human malaria. Generally, microscopic examination is the gold standard for routine malaria diagnosis. However, molecular PCR assays in many cases have shown improvement on the sensitivity and specificity over microscopic or other immunochromatographic assays. METHODS: The present study attempts to screen 207 suspected malaria samples from patients seeking treatment in clinics around Sabah state, Malaysia, using two panels of multiplex PCRs, conventional PCR system (PlasmoNex™) and real-time PCR based on hydrolysis probe technology. Discordance results between two PCR assays were further confirmed by sequencing using 18S ssu rRNA species-specific primers. RESULTS: Of the 207 malaria samples, Plasmodium knowlesi (73.4% vs 72.0%) was the most prevalent species based on two PCR assays, followed by Plasmodium falciparum (15.9% vs 17.9%), and Plasmodium vivax (9.7% vs 7.7%), respectively. Neither Plasmodium malariae nor Plasmodium ovale was detected in this study. Nine discrepant species identification based on both the PCR assays were further confirmed through DNA sequencing. Species-specific real-time PCR only accurately diagnosed 198 of 207 (95.7%) malaria samples up to species level in contrast to PlasmoNex™ assay which had 100% sensitivity and specificity based on sequencing results. CONCLUSIONS: Multiplex PCR accelerate the speed in the diagnosis of malaria. The PlasmoNex™ PCR assay seems to be more accurate than real-time PCR in the speciation of all five human malaria parasites. The present study also showed a significant increase of the potential fatal P. knowlesi infection in Sabah state as revealed by molecular PCR assays. BioMed Central 2015-01-28 /pmc/articles/PMC4318434/ /pubmed/25651852 http://dx.doi.org/10.1186/s12936-015-0542-5 Text en © Lee et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Lee, Ping Chin
Chong, Eric Tzyy Jiann
Anderios, Fread
AL Lim, Yvonne
Chew, Ching Hoong
Chua, Kek Heng
Molecular detection of human Plasmodium species in Sabah using PlasmoNex™ multiplex PCR and hydrolysis probes real-time PCR
title Molecular detection of human Plasmodium species in Sabah using PlasmoNex™ multiplex PCR and hydrolysis probes real-time PCR
title_full Molecular detection of human Plasmodium species in Sabah using PlasmoNex™ multiplex PCR and hydrolysis probes real-time PCR
title_fullStr Molecular detection of human Plasmodium species in Sabah using PlasmoNex™ multiplex PCR and hydrolysis probes real-time PCR
title_full_unstemmed Molecular detection of human Plasmodium species in Sabah using PlasmoNex™ multiplex PCR and hydrolysis probes real-time PCR
title_short Molecular detection of human Plasmodium species in Sabah using PlasmoNex™ multiplex PCR and hydrolysis probes real-time PCR
title_sort molecular detection of human plasmodium species in sabah using plasmonex™ multiplex pcr and hydrolysis probes real-time pcr
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4318434/
https://www.ncbi.nlm.nih.gov/pubmed/25651852
http://dx.doi.org/10.1186/s12936-015-0542-5
work_keys_str_mv AT leepingchin moleculardetectionofhumanplasmodiumspeciesinsabahusingplasmonexmultiplexpcrandhydrolysisprobesrealtimepcr
AT chongerictzyyjiann moleculardetectionofhumanplasmodiumspeciesinsabahusingplasmonexmultiplexpcrandhydrolysisprobesrealtimepcr
AT anderiosfread moleculardetectionofhumanplasmodiumspeciesinsabahusingplasmonexmultiplexpcrandhydrolysisprobesrealtimepcr
AT allimyvonne moleculardetectionofhumanplasmodiumspeciesinsabahusingplasmonexmultiplexpcrandhydrolysisprobesrealtimepcr
AT chewchinghoong moleculardetectionofhumanplasmodiumspeciesinsabahusingplasmonexmultiplexpcrandhydrolysisprobesrealtimepcr
AT chuakekheng moleculardetectionofhumanplasmodiumspeciesinsabahusingplasmonexmultiplexpcrandhydrolysisprobesrealtimepcr