Cargando…
Semi-automated selection of cryo-EM particles in RELION-1.3
The selection of particles suitable for high-resolution cryo-EM structure determination from noisy micrographs may represent a tedious and time-consuming step. Here, a semi-automated particle selection procedure is presented that has been implemented within the open-source software RELION. At the he...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Academic Press
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4318617/ https://www.ncbi.nlm.nih.gov/pubmed/25486611 http://dx.doi.org/10.1016/j.jsb.2014.11.010 |
_version_ | 1782355867281129472 |
---|---|
author | Scheres, Sjors H.W. |
author_facet | Scheres, Sjors H.W. |
author_sort | Scheres, Sjors H.W. |
collection | PubMed |
description | The selection of particles suitable for high-resolution cryo-EM structure determination from noisy micrographs may represent a tedious and time-consuming step. Here, a semi-automated particle selection procedure is presented that has been implemented within the open-source software RELION. At the heart of the procedure lies a fully CTF-corrected template-based picking algorithm, which is supplemented by a fast sorting algorithm and reference-free 2D class averaging to remove false positives. With only limited user-interaction, the proposed procedure yields results that are comparable to manual particle selection. Together with an improved graphical user interface, these developments further contribute to turning RELION from a stand-alone refinement program into a convenient image processing pipeline for the entire single-particle approach. |
format | Online Article Text |
id | pubmed-4318617 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Academic Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-43186172015-02-09 Semi-automated selection of cryo-EM particles in RELION-1.3 Scheres, Sjors H.W. J Struct Biol Article The selection of particles suitable for high-resolution cryo-EM structure determination from noisy micrographs may represent a tedious and time-consuming step. Here, a semi-automated particle selection procedure is presented that has been implemented within the open-source software RELION. At the heart of the procedure lies a fully CTF-corrected template-based picking algorithm, which is supplemented by a fast sorting algorithm and reference-free 2D class averaging to remove false positives. With only limited user-interaction, the proposed procedure yields results that are comparable to manual particle selection. Together with an improved graphical user interface, these developments further contribute to turning RELION from a stand-alone refinement program into a convenient image processing pipeline for the entire single-particle approach. Academic Press 2015-02 /pmc/articles/PMC4318617/ /pubmed/25486611 http://dx.doi.org/10.1016/j.jsb.2014.11.010 Text en © 2014 The Author http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Scheres, Sjors H.W. Semi-automated selection of cryo-EM particles in RELION-1.3 |
title | Semi-automated selection of cryo-EM particles in RELION-1.3 |
title_full | Semi-automated selection of cryo-EM particles in RELION-1.3 |
title_fullStr | Semi-automated selection of cryo-EM particles in RELION-1.3 |
title_full_unstemmed | Semi-automated selection of cryo-EM particles in RELION-1.3 |
title_short | Semi-automated selection of cryo-EM particles in RELION-1.3 |
title_sort | semi-automated selection of cryo-em particles in relion-1.3 |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4318617/ https://www.ncbi.nlm.nih.gov/pubmed/25486611 http://dx.doi.org/10.1016/j.jsb.2014.11.010 |
work_keys_str_mv | AT scheressjorshw semiautomatedselectionofcryoemparticlesinrelion13 |