Semi-automated selection of cryo-EM particles in RELION-1.3

The selection of particles suitable for high-resolution cryo-EM structure determination from noisy micrographs may represent a tedious and time-consuming step. Here, a semi-automated particle selection procedure is presented that has been implemented within the open-source software RELION. At the he...

Descripción completa

Detalles Bibliográficos
Autor principal: Scheres, Sjors H.W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Academic Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4318617/
https://www.ncbi.nlm.nih.gov/pubmed/25486611
http://dx.doi.org/10.1016/j.jsb.2014.11.010
_version_ 1782355867281129472
author Scheres, Sjors H.W.
author_facet Scheres, Sjors H.W.
author_sort Scheres, Sjors H.W.
collection PubMed
description The selection of particles suitable for high-resolution cryo-EM structure determination from noisy micrographs may represent a tedious and time-consuming step. Here, a semi-automated particle selection procedure is presented that has been implemented within the open-source software RELION. At the heart of the procedure lies a fully CTF-corrected template-based picking algorithm, which is supplemented by a fast sorting algorithm and reference-free 2D class averaging to remove false positives. With only limited user-interaction, the proposed procedure yields results that are comparable to manual particle selection. Together with an improved graphical user interface, these developments further contribute to turning RELION from a stand-alone refinement program into a convenient image processing pipeline for the entire single-particle approach.
format Online
Article
Text
id pubmed-4318617
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Academic Press
record_format MEDLINE/PubMed
spelling pubmed-43186172015-02-09 Semi-automated selection of cryo-EM particles in RELION-1.3 Scheres, Sjors H.W. J Struct Biol Article The selection of particles suitable for high-resolution cryo-EM structure determination from noisy micrographs may represent a tedious and time-consuming step. Here, a semi-automated particle selection procedure is presented that has been implemented within the open-source software RELION. At the heart of the procedure lies a fully CTF-corrected template-based picking algorithm, which is supplemented by a fast sorting algorithm and reference-free 2D class averaging to remove false positives. With only limited user-interaction, the proposed procedure yields results that are comparable to manual particle selection. Together with an improved graphical user interface, these developments further contribute to turning RELION from a stand-alone refinement program into a convenient image processing pipeline for the entire single-particle approach. Academic Press 2015-02 /pmc/articles/PMC4318617/ /pubmed/25486611 http://dx.doi.org/10.1016/j.jsb.2014.11.010 Text en © 2014 The Author http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Scheres, Sjors H.W.
Semi-automated selection of cryo-EM particles in RELION-1.3
title Semi-automated selection of cryo-EM particles in RELION-1.3
title_full Semi-automated selection of cryo-EM particles in RELION-1.3
title_fullStr Semi-automated selection of cryo-EM particles in RELION-1.3
title_full_unstemmed Semi-automated selection of cryo-EM particles in RELION-1.3
title_short Semi-automated selection of cryo-EM particles in RELION-1.3
title_sort semi-automated selection of cryo-em particles in relion-1.3
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4318617/
https://www.ncbi.nlm.nih.gov/pubmed/25486611
http://dx.doi.org/10.1016/j.jsb.2014.11.010
work_keys_str_mv AT scheressjorshw semiautomatedselectionofcryoemparticlesinrelion13