Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies
OBJECTIVES: The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. MATERIALS AND METHODS: Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth res...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Conservative Dentistry
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4320273/ https://www.ncbi.nlm.nih.gov/pubmed/25671209 http://dx.doi.org/10.5395/rde.2015.40.1.23 |
_version_ | 1782356095840288768 |
---|---|
author | Bastos, Laura Alves Sousa, Ana Beatriz Silva Drubi-Filho, Brahim Panzeri Pires-de-Souza, Fernanda de Carvalho Garcia, Lucas da Fonseca Roberti |
author_facet | Bastos, Laura Alves Sousa, Ana Beatriz Silva Drubi-Filho, Brahim Panzeri Pires-de-Souza, Fernanda de Carvalho Garcia, Lucas da Fonseca Roberti |
author_sort | Bastos, Laura Alves |
collection | PubMed |
description | OBJECTIVES: The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. MATERIALS AND METHODS: Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesive system (Adhesive System P90, 3M ESPE) was used with and without pre-etching (Pre-etching/Silorane and Silorane groups). Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE) were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray), with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups), or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE) (Three-step/Methacrylate group) (n = 6). The restored teeth were sectioned into stick-shaped test specimens (1.0 × 1.0 mm), and coupled to a universal test machine (0.5 mm/min) to perform microtensile testing. RESULTS: Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p < 0.05). However, it was not significantly different from Preetching/Silorane and Methacrylate groups. CONCLUSIONS: Pre-etching increased bond strength of silorane-based composite specific adhesive system to dentin. |
format | Online Article Text |
id | pubmed-4320273 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Academy of Conservative Dentistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-43202732015-02-10 Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies Bastos, Laura Alves Sousa, Ana Beatriz Silva Drubi-Filho, Brahim Panzeri Pires-de-Souza, Fernanda de Carvalho Garcia, Lucas da Fonseca Roberti Restor Dent Endod Research Article OBJECTIVES: The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. MATERIALS AND METHODS: Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesive system (Adhesive System P90, 3M ESPE) was used with and without pre-etching (Pre-etching/Silorane and Silorane groups). Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE) were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray), with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups), or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE) (Three-step/Methacrylate group) (n = 6). The restored teeth were sectioned into stick-shaped test specimens (1.0 × 1.0 mm), and coupled to a universal test machine (0.5 mm/min) to perform microtensile testing. RESULTS: Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p < 0.05). However, it was not significantly different from Preetching/Silorane and Methacrylate groups. CONCLUSIONS: Pre-etching increased bond strength of silorane-based composite specific adhesive system to dentin. The Korean Academy of Conservative Dentistry 2015-02 2014-08-25 /pmc/articles/PMC4320273/ /pubmed/25671209 http://dx.doi.org/10.5395/rde.2015.40.1.23 Text en ©Copyrights 2015. The Korean Academy of Conservative Dentistry. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Bastos, Laura Alves Sousa, Ana Beatriz Silva Drubi-Filho, Brahim Panzeri Pires-de-Souza, Fernanda de Carvalho Garcia, Lucas da Fonseca Roberti Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies |
title | Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies |
title_full | Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies |
title_fullStr | Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies |
title_full_unstemmed | Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies |
title_short | Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies |
title_sort | microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4320273/ https://www.ncbi.nlm.nih.gov/pubmed/25671209 http://dx.doi.org/10.5395/rde.2015.40.1.23 |
work_keys_str_mv | AT bastoslauraalves microtensilebondstrengthofsiloranebasedcompositespecificadhesivesystemusingdifferentbondingstrategies AT sousaanabeatrizsilva microtensilebondstrengthofsiloranebasedcompositespecificadhesivesystemusingdifferentbondingstrategies AT drubifilhobrahim microtensilebondstrengthofsiloranebasedcompositespecificadhesivesystemusingdifferentbondingstrategies AT panzeripiresdesouzafernandadecarvalho microtensilebondstrengthofsiloranebasedcompositespecificadhesivesystemusingdifferentbondingstrategies AT garcialucasdafonsecaroberti microtensilebondstrengthofsiloranebasedcompositespecificadhesivesystemusingdifferentbondingstrategies |