Cargando…

Alterations Induced by Bangerter Filters on the Visual Field: A Frequency Doubling Technology and Standard Automated Perimetry Study

Purpose. To investigate the effects of Bangerter filters on the visual field in healthy and in amblyopic patients. Materials and Methods. Fifteen normal adults and fifteen anisometropic amblyopia patients were analysed with standard automated perimetry (SAP) and frequency doubling technology (FDT) a...

Descripción completa

Detalles Bibliográficos
Autores principales: Schiavi, Costantino, Tassi, Filippo, Finzi, Alessandro, Cellini, Mauro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4320864/
https://www.ncbi.nlm.nih.gov/pubmed/25688299
http://dx.doi.org/10.1155/2015/909848
_version_ 1782356202135486464
author Schiavi, Costantino
Tassi, Filippo
Finzi, Alessandro
Cellini, Mauro
author_facet Schiavi, Costantino
Tassi, Filippo
Finzi, Alessandro
Cellini, Mauro
author_sort Schiavi, Costantino
collection PubMed
description Purpose. To investigate the effects of Bangerter filters on the visual field in healthy and in amblyopic patients. Materials and Methods. Fifteen normal adults and fifteen anisometropic amblyopia patients were analysed with standard automated perimetry (SAP) and frequency doubling technology (FDT) at baseline and with filters 0.8 and 0.1. Results. With 0.1 filter in SAP there was an increase of MD compared with controls (−10.24 ± 1.09 dB) in either the amblyopic (−11.34 ± 2.06 dB; P < 0.050) or sound eyes (−11.34 ± 1.66 dB; P < 0.030). With filters 0.8 the PSD was increased in the amblyopic eyes (2.09 ± 0.70 dB; P < 0.007) and in the sound eyes (1.92 ± 0.29 dB; P < 0.004) compared with controls. The FDT-PSD values in the control group were increased with the interposition of the filters compared to baseline (0.8; P < 0.0004 and 0.1; P < 0.0010). We did not find significant differences of the baseline PSD between amblyopic eyes (3.80 ± 2.21 dB) and the sound eyes (4.33 ± 1.31 dB) and when comparing the filters 0.8 (4.55 ± 1.50 versus 4.53 ± 1.76 dB) and 0.1 (4.66 ± 1.80 versus 5.10 ± 2.04 dB). Conclusions. The use of Bangerter filters leads to a reduction of the functionality of the magno- and parvocellular pathway.
format Online
Article
Text
id pubmed-4320864
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-43208642015-02-16 Alterations Induced by Bangerter Filters on the Visual Field: A Frequency Doubling Technology and Standard Automated Perimetry Study Schiavi, Costantino Tassi, Filippo Finzi, Alessandro Cellini, Mauro J Ophthalmol Clinical Study Purpose. To investigate the effects of Bangerter filters on the visual field in healthy and in amblyopic patients. Materials and Methods. Fifteen normal adults and fifteen anisometropic amblyopia patients were analysed with standard automated perimetry (SAP) and frequency doubling technology (FDT) at baseline and with filters 0.8 and 0.1. Results. With 0.1 filter in SAP there was an increase of MD compared with controls (−10.24 ± 1.09 dB) in either the amblyopic (−11.34 ± 2.06 dB; P < 0.050) or sound eyes (−11.34 ± 1.66 dB; P < 0.030). With filters 0.8 the PSD was increased in the amblyopic eyes (2.09 ± 0.70 dB; P < 0.007) and in the sound eyes (1.92 ± 0.29 dB; P < 0.004) compared with controls. The FDT-PSD values in the control group were increased with the interposition of the filters compared to baseline (0.8; P < 0.0004 and 0.1; P < 0.0010). We did not find significant differences of the baseline PSD between amblyopic eyes (3.80 ± 2.21 dB) and the sound eyes (4.33 ± 1.31 dB) and when comparing the filters 0.8 (4.55 ± 1.50 versus 4.53 ± 1.76 dB) and 0.1 (4.66 ± 1.80 versus 5.10 ± 2.04 dB). Conclusions. The use of Bangerter filters leads to a reduction of the functionality of the magno- and parvocellular pathway. Hindawi Publishing Corporation 2015 2015-01-20 /pmc/articles/PMC4320864/ /pubmed/25688299 http://dx.doi.org/10.1155/2015/909848 Text en Copyright © 2015 Costantino Schiavi et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Schiavi, Costantino
Tassi, Filippo
Finzi, Alessandro
Cellini, Mauro
Alterations Induced by Bangerter Filters on the Visual Field: A Frequency Doubling Technology and Standard Automated Perimetry Study
title Alterations Induced by Bangerter Filters on the Visual Field: A Frequency Doubling Technology and Standard Automated Perimetry Study
title_full Alterations Induced by Bangerter Filters on the Visual Field: A Frequency Doubling Technology and Standard Automated Perimetry Study
title_fullStr Alterations Induced by Bangerter Filters on the Visual Field: A Frequency Doubling Technology and Standard Automated Perimetry Study
title_full_unstemmed Alterations Induced by Bangerter Filters on the Visual Field: A Frequency Doubling Technology and Standard Automated Perimetry Study
title_short Alterations Induced by Bangerter Filters on the Visual Field: A Frequency Doubling Technology and Standard Automated Perimetry Study
title_sort alterations induced by bangerter filters on the visual field: a frequency doubling technology and standard automated perimetry study
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4320864/
https://www.ncbi.nlm.nih.gov/pubmed/25688299
http://dx.doi.org/10.1155/2015/909848
work_keys_str_mv AT schiavicostantino alterationsinducedbybangerterfiltersonthevisualfieldafrequencydoublingtechnologyandstandardautomatedperimetrystudy
AT tassifilippo alterationsinducedbybangerterfiltersonthevisualfieldafrequencydoublingtechnologyandstandardautomatedperimetrystudy
AT finzialessandro alterationsinducedbybangerterfiltersonthevisualfieldafrequencydoublingtechnologyandstandardautomatedperimetrystudy
AT cellinimauro alterationsinducedbybangerterfiltersonthevisualfieldafrequencydoublingtechnologyandstandardautomatedperimetrystudy