Cargando…
Wrist flexion and extension torques measured by highly sensitive dynamometer in healthy subjects from 5 to 80 years
BACKGROUND: Wrist movements become impaired with disease progression in various neuromuscular disorders. With the development of new therapies, thorough measurement of muscle strength is crucial to document natural disease progression and to assess treatment efficacy. We developed a new dynamometer...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4322806/ https://www.ncbi.nlm.nih.gov/pubmed/25636264 http://dx.doi.org/10.1186/s12891-015-0458-9 |
_version_ | 1782356445883269120 |
---|---|
author | Decostre, Valérie Canal, Aurélie Ollivier, Gwenn Ledoux, Isabelle Moraux, Amélie Doppler, Valérie Payan, Christine Anne Mary Hogrel, Jean-Yves |
author_facet | Decostre, Valérie Canal, Aurélie Ollivier, Gwenn Ledoux, Isabelle Moraux, Amélie Doppler, Valérie Payan, Christine Anne Mary Hogrel, Jean-Yves |
author_sort | Decostre, Valérie |
collection | PubMed |
description | BACKGROUND: Wrist movements become impaired with disease progression in various neuromuscular disorders. With the development of new therapies, thorough measurement of muscle strength is crucial to document natural disease progression and to assess treatment efficacy. We developed a new dynamometer enabling wrist flexion and extension torque measurement with high sensitivity. The aims of the present study were to collect norms for healthy children and adults, to compute predictive equations, to assess the reliability of the measurements and to test the feasibility of using the device in patients with a neuromuscular disease. METHODS: The peak isometric torque of wrist flexion and extension was measured with the MyoWrist dynamometer in 345 healthy subjects aged between 5 and 80 years old and in 9 patients with limb girdle muscle dystrophy type 2 C (LGMD2C) aged between 16 and 38 years old. RESULTS: Predictive equations are proposed for the wrist flexion and extension strength in children and adults. Intra-rater and inter-rater reliability was good with ICCs higher than 0.9 for both wrist flexion and extension. However, retest values were significantly higher by 4% than test results. The dynamometer was applied with no difficulty to patients with LGMD2C and was sensitive enough to detect strength as weak as 0.82 N.m. From our models, we quantified the mean strength of wrist extension in LGMD2C patients to 39 ± 17% of their predicted values. CONCLUSIONS: The MyoWrist dynamometer provides reliable and sensitive measurement of both wrist flexion and extension torques. However, a training session is recommended before starting a study as a small but significant learning effect was observed. Strength deficit can be quantified from predictive equations that were computed from norms of healthy children and adults. |
format | Online Article Text |
id | pubmed-4322806 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-43228062015-02-11 Wrist flexion and extension torques measured by highly sensitive dynamometer in healthy subjects from 5 to 80 years Decostre, Valérie Canal, Aurélie Ollivier, Gwenn Ledoux, Isabelle Moraux, Amélie Doppler, Valérie Payan, Christine Anne Mary Hogrel, Jean-Yves BMC Musculoskelet Disord Research Article BACKGROUND: Wrist movements become impaired with disease progression in various neuromuscular disorders. With the development of new therapies, thorough measurement of muscle strength is crucial to document natural disease progression and to assess treatment efficacy. We developed a new dynamometer enabling wrist flexion and extension torque measurement with high sensitivity. The aims of the present study were to collect norms for healthy children and adults, to compute predictive equations, to assess the reliability of the measurements and to test the feasibility of using the device in patients with a neuromuscular disease. METHODS: The peak isometric torque of wrist flexion and extension was measured with the MyoWrist dynamometer in 345 healthy subjects aged between 5 and 80 years old and in 9 patients with limb girdle muscle dystrophy type 2 C (LGMD2C) aged between 16 and 38 years old. RESULTS: Predictive equations are proposed for the wrist flexion and extension strength in children and adults. Intra-rater and inter-rater reliability was good with ICCs higher than 0.9 for both wrist flexion and extension. However, retest values were significantly higher by 4% than test results. The dynamometer was applied with no difficulty to patients with LGMD2C and was sensitive enough to detect strength as weak as 0.82 N.m. From our models, we quantified the mean strength of wrist extension in LGMD2C patients to 39 ± 17% of their predicted values. CONCLUSIONS: The MyoWrist dynamometer provides reliable and sensitive measurement of both wrist flexion and extension torques. However, a training session is recommended before starting a study as a small but significant learning effect was observed. Strength deficit can be quantified from predictive equations that were computed from norms of healthy children and adults. BioMed Central 2015-01-31 /pmc/articles/PMC4322806/ /pubmed/25636264 http://dx.doi.org/10.1186/s12891-015-0458-9 Text en © Decostre et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Decostre, Valérie Canal, Aurélie Ollivier, Gwenn Ledoux, Isabelle Moraux, Amélie Doppler, Valérie Payan, Christine Anne Mary Hogrel, Jean-Yves Wrist flexion and extension torques measured by highly sensitive dynamometer in healthy subjects from 5 to 80 years |
title | Wrist flexion and extension torques measured by highly sensitive dynamometer in healthy subjects from 5 to 80 years |
title_full | Wrist flexion and extension torques measured by highly sensitive dynamometer in healthy subjects from 5 to 80 years |
title_fullStr | Wrist flexion and extension torques measured by highly sensitive dynamometer in healthy subjects from 5 to 80 years |
title_full_unstemmed | Wrist flexion and extension torques measured by highly sensitive dynamometer in healthy subjects from 5 to 80 years |
title_short | Wrist flexion and extension torques measured by highly sensitive dynamometer in healthy subjects from 5 to 80 years |
title_sort | wrist flexion and extension torques measured by highly sensitive dynamometer in healthy subjects from 5 to 80 years |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4322806/ https://www.ncbi.nlm.nih.gov/pubmed/25636264 http://dx.doi.org/10.1186/s12891-015-0458-9 |
work_keys_str_mv | AT decostrevalerie wristflexionandextensiontorquesmeasuredbyhighlysensitivedynamometerinhealthysubjectsfrom5to80years AT canalaurelie wristflexionandextensiontorquesmeasuredbyhighlysensitivedynamometerinhealthysubjectsfrom5to80years AT olliviergwenn wristflexionandextensiontorquesmeasuredbyhighlysensitivedynamometerinhealthysubjectsfrom5to80years AT ledouxisabelle wristflexionandextensiontorquesmeasuredbyhighlysensitivedynamometerinhealthysubjectsfrom5to80years AT morauxamelie wristflexionandextensiontorquesmeasuredbyhighlysensitivedynamometerinhealthysubjectsfrom5to80years AT dopplervalerie wristflexionandextensiontorquesmeasuredbyhighlysensitivedynamometerinhealthysubjectsfrom5to80years AT payanchristineannemary wristflexionandextensiontorquesmeasuredbyhighlysensitivedynamometerinhealthysubjectsfrom5to80years AT hogreljeanyves wristflexionandextensiontorquesmeasuredbyhighlysensitivedynamometerinhealthysubjectsfrom5to80years |