Quantitative pixel-wise measurement of myocardial blood flow: The impact of surface coil-related field inhomogeneity and a comparison of methods for its correction

BACKGROUND: Surface coil-related field inhomogeneity potentially confounds pixel-wise quantitative analysis of perfusion CMR images. This study assessed the effect of surface coil-related field inhomogeneity on the spatial variation of pixel-wise myocardial blood flow (MBF), and assessed its impact...

Descripción completa

Detalles Bibliográficos
Autores principales: Miller, Christopher A, Hsu, Li-Yueh, Ta, Allison, Conn, Hannah, Winkler, Susanne, Arai, Andrew E
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4323126/
https://www.ncbi.nlm.nih.gov/pubmed/25827156
http://dx.doi.org/10.1186/s12968-015-0117-1
_version_ 1782356497155489792
author Miller, Christopher A
Hsu, Li-Yueh
Ta, Allison
Conn, Hannah
Winkler, Susanne
Arai, Andrew E
author_facet Miller, Christopher A
Hsu, Li-Yueh
Ta, Allison
Conn, Hannah
Winkler, Susanne
Arai, Andrew E
author_sort Miller, Christopher A
collection PubMed
description BACKGROUND: Surface coil-related field inhomogeneity potentially confounds pixel-wise quantitative analysis of perfusion CMR images. This study assessed the effect of surface coil-related field inhomogeneity on the spatial variation of pixel-wise myocardial blood flow (MBF), and assessed its impact on the ability of MBF quantification to differentiate ischaemic from remote coronary territories. Two surface coil intensity correction (SCIC) techniques were evaluated: 1) a proton density-based technique (PD-SCIC) and; 2) a saturation recovery steady-state free precession-based technique (SSFP-SCIC). METHODS: 26 subjects (18 with significant CAD and 8 healthy volunteers) underwent stress perfusion CMR using a motion-corrected, saturation recovery SSFP dual-sequence protocol. A proton density (PD)-weighted image was acquired at the beginning of the sequence. Surface coil-related field inhomogeneity was approximated using a third-order surface fit to the PD image or a pre-contrast saturation prepared SSFP image. The estimated intensity bias field was subsequently applied to the image series. Pixel-wise MBF was measured from mid-ventricular stress images using the two SCIC approaches and compared to measurements made without SCIC. RESULTS: MBF heterogeneity in healthy volunteers was higher using SSFP-SCIC (24.8 ± 4.1%) compared to PD-SCIC (20.8 ± 3.0%; p = 0.009), however heterogeneity was significantly lower using either SCIC technique compared to analysis performed without SCIC (36.2 ± 6.3%). In CAD patients, the difference in MBF between remote and ischaemic territories was minimal when analysis was performed without SCIC (0.06 ± 0.91 mL/min/kg), and was substantially lower than with either PD-SCIC (0.50 ± 0.63 mL/min/kg; p = 0.013) or with SSFP-SCIC (0.63 ± 0.89 mL/min/kg; p = 0.005). In 6 patients, MBF quantified without SCIC was artifactually higher in the stenosed coronary territory compared to the remote territory. PD-SCIC and SSFP-SCIC had similar differences in MBF between remote and ischaemic territories (p = 0.145). CONCLUSIONS: This study demonstrates that surface coil-related field inhomogeneity can confound pixel-wise MBF quantification. Whilst a PD-based SCIC led to a more homogenous correction than a saturation recovery SSFP-based technique, this did not result in an appreciable difference in the differentiation of ischaemic from remote coronary territories and thus either method could be applied.
format Online
Article
Text
id pubmed-4323126
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-43231262015-02-11 Quantitative pixel-wise measurement of myocardial blood flow: The impact of surface coil-related field inhomogeneity and a comparison of methods for its correction Miller, Christopher A Hsu, Li-Yueh Ta, Allison Conn, Hannah Winkler, Susanne Arai, Andrew E J Cardiovasc Magn Reson Research BACKGROUND: Surface coil-related field inhomogeneity potentially confounds pixel-wise quantitative analysis of perfusion CMR images. This study assessed the effect of surface coil-related field inhomogeneity on the spatial variation of pixel-wise myocardial blood flow (MBF), and assessed its impact on the ability of MBF quantification to differentiate ischaemic from remote coronary territories. Two surface coil intensity correction (SCIC) techniques were evaluated: 1) a proton density-based technique (PD-SCIC) and; 2) a saturation recovery steady-state free precession-based technique (SSFP-SCIC). METHODS: 26 subjects (18 with significant CAD and 8 healthy volunteers) underwent stress perfusion CMR using a motion-corrected, saturation recovery SSFP dual-sequence protocol. A proton density (PD)-weighted image was acquired at the beginning of the sequence. Surface coil-related field inhomogeneity was approximated using a third-order surface fit to the PD image or a pre-contrast saturation prepared SSFP image. The estimated intensity bias field was subsequently applied to the image series. Pixel-wise MBF was measured from mid-ventricular stress images using the two SCIC approaches and compared to measurements made without SCIC. RESULTS: MBF heterogeneity in healthy volunteers was higher using SSFP-SCIC (24.8 ± 4.1%) compared to PD-SCIC (20.8 ± 3.0%; p = 0.009), however heterogeneity was significantly lower using either SCIC technique compared to analysis performed without SCIC (36.2 ± 6.3%). In CAD patients, the difference in MBF between remote and ischaemic territories was minimal when analysis was performed without SCIC (0.06 ± 0.91 mL/min/kg), and was substantially lower than with either PD-SCIC (0.50 ± 0.63 mL/min/kg; p = 0.013) or with SSFP-SCIC (0.63 ± 0.89 mL/min/kg; p = 0.005). In 6 patients, MBF quantified without SCIC was artifactually higher in the stenosed coronary territory compared to the remote territory. PD-SCIC and SSFP-SCIC had similar differences in MBF between remote and ischaemic territories (p = 0.145). CONCLUSIONS: This study demonstrates that surface coil-related field inhomogeneity can confound pixel-wise MBF quantification. Whilst a PD-based SCIC led to a more homogenous correction than a saturation recovery SSFP-based technique, this did not result in an appreciable difference in the differentiation of ischaemic from remote coronary territories and thus either method could be applied. BioMed Central 2015-02-11 /pmc/articles/PMC4323126/ /pubmed/25827156 http://dx.doi.org/10.1186/s12968-015-0117-1 Text en © Miller et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Miller, Christopher A
Hsu, Li-Yueh
Ta, Allison
Conn, Hannah
Winkler, Susanne
Arai, Andrew E
Quantitative pixel-wise measurement of myocardial blood flow: The impact of surface coil-related field inhomogeneity and a comparison of methods for its correction
title Quantitative pixel-wise measurement of myocardial blood flow: The impact of surface coil-related field inhomogeneity and a comparison of methods for its correction
title_full Quantitative pixel-wise measurement of myocardial blood flow: The impact of surface coil-related field inhomogeneity and a comparison of methods for its correction
title_fullStr Quantitative pixel-wise measurement of myocardial blood flow: The impact of surface coil-related field inhomogeneity and a comparison of methods for its correction
title_full_unstemmed Quantitative pixel-wise measurement of myocardial blood flow: The impact of surface coil-related field inhomogeneity and a comparison of methods for its correction
title_short Quantitative pixel-wise measurement of myocardial blood flow: The impact of surface coil-related field inhomogeneity and a comparison of methods for its correction
title_sort quantitative pixel-wise measurement of myocardial blood flow: the impact of surface coil-related field inhomogeneity and a comparison of methods for its correction
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4323126/
https://www.ncbi.nlm.nih.gov/pubmed/25827156
http://dx.doi.org/10.1186/s12968-015-0117-1
work_keys_str_mv AT millerchristophera quantitativepixelwisemeasurementofmyocardialbloodflowtheimpactofsurfacecoilrelatedfieldinhomogeneityandacomparisonofmethodsforitscorrection
AT hsuliyueh quantitativepixelwisemeasurementofmyocardialbloodflowtheimpactofsurfacecoilrelatedfieldinhomogeneityandacomparisonofmethodsforitscorrection
AT taallison quantitativepixelwisemeasurementofmyocardialbloodflowtheimpactofsurfacecoilrelatedfieldinhomogeneityandacomparisonofmethodsforitscorrection
AT connhannah quantitativepixelwisemeasurementofmyocardialbloodflowtheimpactofsurfacecoilrelatedfieldinhomogeneityandacomparisonofmethodsforitscorrection
AT winklersusanne quantitativepixelwisemeasurementofmyocardialbloodflowtheimpactofsurfacecoilrelatedfieldinhomogeneityandacomparisonofmethodsforitscorrection
AT araiandrewe quantitativepixelwisemeasurementofmyocardialbloodflowtheimpactofsurfacecoilrelatedfieldinhomogeneityandacomparisonofmethodsforitscorrection