Cargando…

Comparative Validity and Reproducibility Study of Various Landmark-Oriented Reference Planes in 3-Dimensional Computed Tomographic Analysis for Patients Receiving Orthognathic Surgery

BACKGROUND: Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based h...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Hsiu-Hsia, Chuang, Ya-Fang, Weng, Jing-Ling, Lo, Lun-Jou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4323243/
https://www.ncbi.nlm.nih.gov/pubmed/25668209
http://dx.doi.org/10.1371/journal.pone.0117604
_version_ 1782356514956115968
author Lin, Hsiu-Hsia
Chuang, Ya-Fang
Weng, Jing-Ling
Lo, Lun-Jou
author_facet Lin, Hsiu-Hsia
Chuang, Ya-Fang
Weng, Jing-Ling
Lo, Lun-Jou
author_sort Lin, Hsiu-Hsia
collection PubMed
description BACKGROUND: Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. MATERIALS AND METHODS: Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. RESULTS: A total of 30 patients with facial deformity and malocclusion—10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate—were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. CONCLUSIONS: The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models.
format Online
Article
Text
id pubmed-4323243
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-43232432015-02-18 Comparative Validity and Reproducibility Study of Various Landmark-Oriented Reference Planes in 3-Dimensional Computed Tomographic Analysis for Patients Receiving Orthognathic Surgery Lin, Hsiu-Hsia Chuang, Ya-Fang Weng, Jing-Ling Lo, Lun-Jou PLoS One Research Article BACKGROUND: Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. MATERIALS AND METHODS: Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. RESULTS: A total of 30 patients with facial deformity and malocclusion—10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate—were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. CONCLUSIONS: The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models. Public Library of Science 2015-02-10 /pmc/articles/PMC4323243/ /pubmed/25668209 http://dx.doi.org/10.1371/journal.pone.0117604 Text en © 2015 Lin et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Lin, Hsiu-Hsia
Chuang, Ya-Fang
Weng, Jing-Ling
Lo, Lun-Jou
Comparative Validity and Reproducibility Study of Various Landmark-Oriented Reference Planes in 3-Dimensional Computed Tomographic Analysis for Patients Receiving Orthognathic Surgery
title Comparative Validity and Reproducibility Study of Various Landmark-Oriented Reference Planes in 3-Dimensional Computed Tomographic Analysis for Patients Receiving Orthognathic Surgery
title_full Comparative Validity and Reproducibility Study of Various Landmark-Oriented Reference Planes in 3-Dimensional Computed Tomographic Analysis for Patients Receiving Orthognathic Surgery
title_fullStr Comparative Validity and Reproducibility Study of Various Landmark-Oriented Reference Planes in 3-Dimensional Computed Tomographic Analysis for Patients Receiving Orthognathic Surgery
title_full_unstemmed Comparative Validity and Reproducibility Study of Various Landmark-Oriented Reference Planes in 3-Dimensional Computed Tomographic Analysis for Patients Receiving Orthognathic Surgery
title_short Comparative Validity and Reproducibility Study of Various Landmark-Oriented Reference Planes in 3-Dimensional Computed Tomographic Analysis for Patients Receiving Orthognathic Surgery
title_sort comparative validity and reproducibility study of various landmark-oriented reference planes in 3-dimensional computed tomographic analysis for patients receiving orthognathic surgery
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4323243/
https://www.ncbi.nlm.nih.gov/pubmed/25668209
http://dx.doi.org/10.1371/journal.pone.0117604
work_keys_str_mv AT linhsiuhsia comparativevalidityandreproducibilitystudyofvariouslandmarkorientedreferenceplanesin3dimensionalcomputedtomographicanalysisforpatientsreceivingorthognathicsurgery
AT chuangyafang comparativevalidityandreproducibilitystudyofvariouslandmarkorientedreferenceplanesin3dimensionalcomputedtomographicanalysisforpatientsreceivingorthognathicsurgery
AT wengjingling comparativevalidityandreproducibilitystudyofvariouslandmarkorientedreferenceplanesin3dimensionalcomputedtomographicanalysisforpatientsreceivingorthognathicsurgery
AT lolunjou comparativevalidityandreproducibilitystudyofvariouslandmarkorientedreferenceplanesin3dimensionalcomputedtomographicanalysisforpatientsreceivingorthognathicsurgery