Cargando…
Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials
BACKGROUND: In recent years, the choice of ceramic-on-ceramic (COC) and metal-on-polyethylene (MOP) in primary total hip arthroplasty (THA) remains controversial. The purpose of this study was to compare the reliability and durability of COC with that of MOP bearing surfaces in THA. METHODS: Based o...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4324779/ https://www.ncbi.nlm.nih.gov/pubmed/25645809 http://dx.doi.org/10.1186/s13018-015-0163-2 |
_version_ | 1782356720755933184 |
---|---|
author | Hu, Dongcai Tie, Kai Yang, Xiao Tan, Yang Alaidaros, Mohammed Chen, Liaobin |
author_facet | Hu, Dongcai Tie, Kai Yang, Xiao Tan, Yang Alaidaros, Mohammed Chen, Liaobin |
author_sort | Hu, Dongcai |
collection | PubMed |
description | BACKGROUND: In recent years, the choice of ceramic-on-ceramic (COC) and metal-on-polyethylene (MOP) in primary total hip arthroplasty (THA) remains controversial. The purpose of this study was to compare the reliability and durability of COC with that of MOP bearing surfaces in THA. METHODS: Based on prospective randomized controlled trials (RCTs) searched from Pubmed, Embase, Web of Science, and Cochrane central database, we performed a meta-analysis for comparing clinical and radiographic outcomes of COC with those of MOP. Two investigators independently selected studies, extracted data, and assessed risk of bias. Relative risks and weighted mean differences from each trial were pooled using random-effect or fixed-effect models depending on the heterogeneity of the included studies. RESULTS: Five RCTs involving 897 patients with 974 hips met predetermined inclusion criteria. Our results demonstrated COC significantly decreased the risks of revision, osteolysis and radiolucent line, aseptic loosening, and dislocation and increased the risks of squeaking and intraoperative implant fracture compared with MOP. There was no significant difference between the two groups in postoperative hip function, deep infection, and heterotopic ossification. CONCLUSIONS: Generally, despite more squeaking and intraoperative implant fracture, our findings support the use of COC bearing surface which has lower rates of revision, osteolysis and radiolucent line, aseptic loosening, and dislocation compared with MOP. |
format | Online Article Text |
id | pubmed-4324779 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-43247792015-02-12 Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials Hu, Dongcai Tie, Kai Yang, Xiao Tan, Yang Alaidaros, Mohammed Chen, Liaobin J Orthop Surg Res Research Article BACKGROUND: In recent years, the choice of ceramic-on-ceramic (COC) and metal-on-polyethylene (MOP) in primary total hip arthroplasty (THA) remains controversial. The purpose of this study was to compare the reliability and durability of COC with that of MOP bearing surfaces in THA. METHODS: Based on prospective randomized controlled trials (RCTs) searched from Pubmed, Embase, Web of Science, and Cochrane central database, we performed a meta-analysis for comparing clinical and radiographic outcomes of COC with those of MOP. Two investigators independently selected studies, extracted data, and assessed risk of bias. Relative risks and weighted mean differences from each trial were pooled using random-effect or fixed-effect models depending on the heterogeneity of the included studies. RESULTS: Five RCTs involving 897 patients with 974 hips met predetermined inclusion criteria. Our results demonstrated COC significantly decreased the risks of revision, osteolysis and radiolucent line, aseptic loosening, and dislocation and increased the risks of squeaking and intraoperative implant fracture compared with MOP. There was no significant difference between the two groups in postoperative hip function, deep infection, and heterotopic ossification. CONCLUSIONS: Generally, despite more squeaking and intraoperative implant fracture, our findings support the use of COC bearing surface which has lower rates of revision, osteolysis and radiolucent line, aseptic loosening, and dislocation compared with MOP. BioMed Central 2015-02-03 /pmc/articles/PMC4324779/ /pubmed/25645809 http://dx.doi.org/10.1186/s13018-015-0163-2 Text en © Hu et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Hu, Dongcai Tie, Kai Yang, Xiao Tan, Yang Alaidaros, Mohammed Chen, Liaobin Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials |
title | Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials |
title_full | Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials |
title_fullStr | Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials |
title_full_unstemmed | Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials |
title_short | Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials |
title_sort | comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4324779/ https://www.ncbi.nlm.nih.gov/pubmed/25645809 http://dx.doi.org/10.1186/s13018-015-0163-2 |
work_keys_str_mv | AT hudongcai comparisonofceramiconceramictometalonpolyethylenebearingsurfacesintotalhiparthroplastyametaanalysisofrandomizedcontrolledtrials AT tiekai comparisonofceramiconceramictometalonpolyethylenebearingsurfacesintotalhiparthroplastyametaanalysisofrandomizedcontrolledtrials AT yangxiao comparisonofceramiconceramictometalonpolyethylenebearingsurfacesintotalhiparthroplastyametaanalysisofrandomizedcontrolledtrials AT tanyang comparisonofceramiconceramictometalonpolyethylenebearingsurfacesintotalhiparthroplastyametaanalysisofrandomizedcontrolledtrials AT alaidarosmohammed comparisonofceramiconceramictometalonpolyethylenebearingsurfacesintotalhiparthroplastyametaanalysisofrandomizedcontrolledtrials AT chenliaobin comparisonofceramiconceramictometalonpolyethylenebearingsurfacesintotalhiparthroplastyametaanalysisofrandomizedcontrolledtrials |