Cargando…
The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients
OBJECTIVE: This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly po...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Society for the Advancement of Spine Surgery
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4325487/ https://www.ncbi.nlm.nih.gov/pubmed/25694919 http://dx.doi.org/10.14444/1027 |
_version_ | 1782356811563663360 |
---|---|
author | Wood, Martin James McMillen, Jason |
author_facet | Wood, Martin James McMillen, Jason |
author_sort | Wood, Martin James |
collection | PubMed |
description | OBJECTIVE: This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. METHODS: Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. RESULTS: Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. CONCLUSION: The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique. |
format | Online Article Text |
id | pubmed-4325487 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | International Society for the Advancement of Spine Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-43254872015-02-18 The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients Wood, Martin James McMillen, Jason Int J Spine Surg Article OBJECTIVE: This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. METHODS: Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. RESULTS: Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. CONCLUSION: The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique. International Society for the Advancement of Spine Surgery 2014-12-01 /pmc/articles/PMC4325487/ /pubmed/25694919 http://dx.doi.org/10.14444/1027 Text en Copyright © 2014 ISASS - International Society for the Advancement of Spine Surgery http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Article Wood, Martin James McMillen, Jason The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients |
title | The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients |
title_full | The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients |
title_fullStr | The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients |
title_full_unstemmed | The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients |
title_short | The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients |
title_sort | surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using ct based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4325487/ https://www.ncbi.nlm.nih.gov/pubmed/25694919 http://dx.doi.org/10.14444/1027 |
work_keys_str_mv | AT woodmartinjames thesurgicallearningcurveandaccuracyofminimallyinvasivelumbarpediclescrewplacementusingctbasedcomputerassistednavigationpluscontinuouselectromyographymonitoringaretrospectivereviewof627screwsin150patients AT mcmillenjason thesurgicallearningcurveandaccuracyofminimallyinvasivelumbarpediclescrewplacementusingctbasedcomputerassistednavigationpluscontinuouselectromyographymonitoringaretrospectivereviewof627screwsin150patients AT woodmartinjames surgicallearningcurveandaccuracyofminimallyinvasivelumbarpediclescrewplacementusingctbasedcomputerassistednavigationpluscontinuouselectromyographymonitoringaretrospectivereviewof627screwsin150patients AT mcmillenjason surgicallearningcurveandaccuracyofminimallyinvasivelumbarpediclescrewplacementusingctbasedcomputerassistednavigationpluscontinuouselectromyographymonitoringaretrospectivereviewof627screwsin150patients |