Cargando…
BOND STRENGTH OF RESIN MODIFIED GLASS IONOMER CEMENT TO PRIMARY DENTIN AFTER CUTTING WITH DIFFERENT BUR TYPES AND DENTIN CONDITIONING
The aim of this in vitro study was to evaluate the effect of different bur types and acid etching protocols on the shear bond strength (SBS) of a resin modified glass ionomer cement (RM-GIC) to primary dentin. Forty-eight clinically sound human primary molars were selected and randomly assigned to f...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Faculdade de Odontologia de Bauru da Universidade de São Paulo
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327270/ https://www.ncbi.nlm.nih.gov/pubmed/19089179 http://dx.doi.org/10.1590/S1678-7757200700050001 |
_version_ | 1782357047445028864 |
---|---|
author | Nicoló, Rebeca Di Shintome, Luciana Keiko Myaki, Silvio Issáo Nagayassu, Marcos Paulo |
author_facet | Nicoló, Rebeca Di Shintome, Luciana Keiko Myaki, Silvio Issáo Nagayassu, Marcos Paulo |
author_sort | Nicoló, Rebeca Di |
collection | PubMed |
description | The aim of this in vitro study was to evaluate the effect of different bur types and acid etching protocols on the shear bond strength (SBS) of a resin modified glass ionomer cement (RM-GIC) to primary dentin. Forty-eight clinically sound human primary molars were selected and randomly assigned to four groups (n=12). In G1, the lingual surface of the teeth was cut with a carbide bur until a 2.0-mm-diameter dentin area was exposed, followed by the application of RM-GIC (Vitremer – 3M/ESPE) prepared according to the manufacturer’s instructions. The specimens of G2, received the same treatment of G1, however the dentin was conditioned with phosphoric acid. In groups G3 and G4 the same procedures of G1 and G2 were conducted respectively, nevertheless dentin cutting was made with a diamond bur. The specimens were stored in distilled water at 37°C for 24h, and then tested in a universal testing machine. SBS. data were submitted to 2-way ANOVA (= 5%) and indicated that SBS values of RM-GIC bonded to primary dentin cut with different burs were not statistically different, but the specimens that were conditioned with phosphoric acid presented SBS values significantly higher that those without conditioning. To observe micromorphologic characteristics of the effects of dentin surface cut by diamond or carbide rotary instruments and conditioners treatment, some specimens were examined by scanning electron microscopy. Smear layer was present in all specimens regardless of the type of rotary instrument used for dentin cutting, and specimens etched with phosphoric acid presented more effective removal of smear layer. It was concluded that SBS of a RM-GIC to primary dentin was affected by the acid conditioning but the bur type had no influence. |
format | Online Article Text |
id | pubmed-4327270 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | Faculdade de Odontologia de Bauru da Universidade de São Paulo |
record_format | MEDLINE/PubMed |
spelling | pubmed-43272702015-04-24 BOND STRENGTH OF RESIN MODIFIED GLASS IONOMER CEMENT TO PRIMARY DENTIN AFTER CUTTING WITH DIFFERENT BUR TYPES AND DENTIN CONDITIONING Nicoló, Rebeca Di Shintome, Luciana Keiko Myaki, Silvio Issáo Nagayassu, Marcos Paulo J Appl Oral Sci Original Article The aim of this in vitro study was to evaluate the effect of different bur types and acid etching protocols on the shear bond strength (SBS) of a resin modified glass ionomer cement (RM-GIC) to primary dentin. Forty-eight clinically sound human primary molars were selected and randomly assigned to four groups (n=12). In G1, the lingual surface of the teeth was cut with a carbide bur until a 2.0-mm-diameter dentin area was exposed, followed by the application of RM-GIC (Vitremer – 3M/ESPE) prepared according to the manufacturer’s instructions. The specimens of G2, received the same treatment of G1, however the dentin was conditioned with phosphoric acid. In groups G3 and G4 the same procedures of G1 and G2 were conducted respectively, nevertheless dentin cutting was made with a diamond bur. The specimens were stored in distilled water at 37°C for 24h, and then tested in a universal testing machine. SBS. data were submitted to 2-way ANOVA (= 5%) and indicated that SBS values of RM-GIC bonded to primary dentin cut with different burs were not statistically different, but the specimens that were conditioned with phosphoric acid presented SBS values significantly higher that those without conditioning. To observe micromorphologic characteristics of the effects of dentin surface cut by diamond or carbide rotary instruments and conditioners treatment, some specimens were examined by scanning electron microscopy. Smear layer was present in all specimens regardless of the type of rotary instrument used for dentin cutting, and specimens etched with phosphoric acid presented more effective removal of smear layer. It was concluded that SBS of a RM-GIC to primary dentin was affected by the acid conditioning but the bur type had no influence. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2007-10 /pmc/articles/PMC4327270/ /pubmed/19089179 http://dx.doi.org/10.1590/S1678-7757200700050001 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Nicoló, Rebeca Di Shintome, Luciana Keiko Myaki, Silvio Issáo Nagayassu, Marcos Paulo BOND STRENGTH OF RESIN MODIFIED GLASS IONOMER CEMENT TO PRIMARY DENTIN AFTER CUTTING WITH DIFFERENT BUR TYPES AND DENTIN CONDITIONING |
title | BOND STRENGTH OF RESIN MODIFIED GLASS IONOMER CEMENT TO PRIMARY DENTIN AFTER CUTTING WITH DIFFERENT BUR TYPES AND DENTIN CONDITIONING |
title_full | BOND STRENGTH OF RESIN MODIFIED GLASS IONOMER CEMENT TO PRIMARY DENTIN AFTER CUTTING WITH DIFFERENT BUR TYPES AND DENTIN CONDITIONING |
title_fullStr | BOND STRENGTH OF RESIN MODIFIED GLASS IONOMER CEMENT TO PRIMARY DENTIN AFTER CUTTING WITH DIFFERENT BUR TYPES AND DENTIN CONDITIONING |
title_full_unstemmed | BOND STRENGTH OF RESIN MODIFIED GLASS IONOMER CEMENT TO PRIMARY DENTIN AFTER CUTTING WITH DIFFERENT BUR TYPES AND DENTIN CONDITIONING |
title_short | BOND STRENGTH OF RESIN MODIFIED GLASS IONOMER CEMENT TO PRIMARY DENTIN AFTER CUTTING WITH DIFFERENT BUR TYPES AND DENTIN CONDITIONING |
title_sort | bond strength of resin modified glass ionomer cement to primary dentin after cutting with different bur types and dentin conditioning |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327270/ https://www.ncbi.nlm.nih.gov/pubmed/19089179 http://dx.doi.org/10.1590/S1678-7757200700050001 |
work_keys_str_mv | AT nicolorebecadi bondstrengthofresinmodifiedglassionomercementtoprimarydentinaftercuttingwithdifferentburtypesanddentinconditioning AT shintomelucianakeiko bondstrengthofresinmodifiedglassionomercementtoprimarydentinaftercuttingwithdifferentburtypesanddentinconditioning AT myakisilvioissao bondstrengthofresinmodifiedglassionomercementtoprimarydentinaftercuttingwithdifferentburtypesanddentinconditioning AT nagayassumarcospaulo bondstrengthofresinmodifiedglassionomercementtoprimarydentinaftercuttingwithdifferentburtypesanddentinconditioning |