Cargando…

THE INFLUENCE OF SCREW TYPE, ALLOY AND CYLINDER POSITION ON THE MARGINAL FIT OF IMPLANT FRAMEWORKS BEFORE AND AFTER LASER WELDING

Misfit at the abutment-prosthetic cylinder interface can cause loss of preload, leading to loosening or fracture of gold and titanium screws. Objectives: To evaluate the influence of screw type, alloy, and cylinder position on marginal fit of implant frameworks before and after laser welding. Method...

Descripción completa

Detalles Bibliográficos
Autores principales: Castilio, Daniela, Pedreira, Ana Paula Ribeiro do Vale, Rossetti, Paulo Henrique Orlato, Rossetti, Leylha Maria Nunes, Bonachela, Wellington Cardoso
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade de Odontologia de Bauru da Universidade de São Paulo 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327446/
https://www.ncbi.nlm.nih.gov/pubmed/19089035
http://dx.doi.org/10.1590/S1678-77572006000200003
_version_ 1782357081177718784
author Castilio, Daniela
Pedreira, Ana Paula Ribeiro do Vale
Rossetti, Paulo Henrique Orlato
Rossetti, Leylha Maria Nunes
Bonachela, Wellington Cardoso
author_facet Castilio, Daniela
Pedreira, Ana Paula Ribeiro do Vale
Rossetti, Paulo Henrique Orlato
Rossetti, Leylha Maria Nunes
Bonachela, Wellington Cardoso
author_sort Castilio, Daniela
collection PubMed
description Misfit at the abutment-prosthetic cylinder interface can cause loss of preload, leading to loosening or fracture of gold and titanium screws. Objectives: To evaluate the influence of screw type, alloy, and cylinder position on marginal fit of implant frameworks before and after laser welding. Methods: After Estheticone-like abutments were screwed to the implants, thirty plastic prosthetic cylinders were mounted and waxed-up to fifteen cylindrical bars. Each specimen had three interconnected prosthetic components. Five specimens were one-piece cast in titanium and five in cobalt-chromium alloy. On each specimen, tests were conducted with hexagonal titanium and slotted gold screws separately, performing a total of thirty tested screws. Measurements at the interfaces were performed using an optical microscope with 5 μm accuracy. After sectioning, specimens were laser welded and new measurements were obtained. Data were submitted to a four-way ANOVA and Tukey's multiple comparisons test (α =0.05). Results: Slotted and hexagonal screws did not present significant differences regarding to the fit of cylinders cast in titanium, either in one-piece casting framework or after laser welding. When slotted and hexagonal screws were tested on the cobalt-chromium specimens, statistically significant differences were found for the one-piece casting condition, with the slotted screws presenting better fit (24.13μm) than the hexagonal screws (27.93 μm). Besides, no statistically significant differences were found after laser welding. Conclusions: 1) The use of different metal alloys do exert influence on the marginal fit, 2) The slotted and hexagonal screws play the exclusive role of fixing the prosthesis, and did not improve the fit of cylinders, and 3) cylinder position did not affect marginal fit values.
format Online
Article
Text
id pubmed-4327446
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher Faculdade de Odontologia de Bauru da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-43274462015-04-23 THE INFLUENCE OF SCREW TYPE, ALLOY AND CYLINDER POSITION ON THE MARGINAL FIT OF IMPLANT FRAMEWORKS BEFORE AND AFTER LASER WELDING Castilio, Daniela Pedreira, Ana Paula Ribeiro do Vale Rossetti, Paulo Henrique Orlato Rossetti, Leylha Maria Nunes Bonachela, Wellington Cardoso J Appl Oral Sci Original Article Misfit at the abutment-prosthetic cylinder interface can cause loss of preload, leading to loosening or fracture of gold and titanium screws. Objectives: To evaluate the influence of screw type, alloy, and cylinder position on marginal fit of implant frameworks before and after laser welding. Methods: After Estheticone-like abutments were screwed to the implants, thirty plastic prosthetic cylinders were mounted and waxed-up to fifteen cylindrical bars. Each specimen had three interconnected prosthetic components. Five specimens were one-piece cast in titanium and five in cobalt-chromium alloy. On each specimen, tests were conducted with hexagonal titanium and slotted gold screws separately, performing a total of thirty tested screws. Measurements at the interfaces were performed using an optical microscope with 5 μm accuracy. After sectioning, specimens were laser welded and new measurements were obtained. Data were submitted to a four-way ANOVA and Tukey's multiple comparisons test (α =0.05). Results: Slotted and hexagonal screws did not present significant differences regarding to the fit of cylinders cast in titanium, either in one-piece casting framework or after laser welding. When slotted and hexagonal screws were tested on the cobalt-chromium specimens, statistically significant differences were found for the one-piece casting condition, with the slotted screws presenting better fit (24.13μm) than the hexagonal screws (27.93 μm). Besides, no statistically significant differences were found after laser welding. Conclusions: 1) The use of different metal alloys do exert influence on the marginal fit, 2) The slotted and hexagonal screws play the exclusive role of fixing the prosthesis, and did not improve the fit of cylinders, and 3) cylinder position did not affect marginal fit values. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2006-04 /pmc/articles/PMC4327446/ /pubmed/19089035 http://dx.doi.org/10.1590/S1678-77572006000200003 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Castilio, Daniela
Pedreira, Ana Paula Ribeiro do Vale
Rossetti, Paulo Henrique Orlato
Rossetti, Leylha Maria Nunes
Bonachela, Wellington Cardoso
THE INFLUENCE OF SCREW TYPE, ALLOY AND CYLINDER POSITION ON THE MARGINAL FIT OF IMPLANT FRAMEWORKS BEFORE AND AFTER LASER WELDING
title THE INFLUENCE OF SCREW TYPE, ALLOY AND CYLINDER POSITION ON THE MARGINAL FIT OF IMPLANT FRAMEWORKS BEFORE AND AFTER LASER WELDING
title_full THE INFLUENCE OF SCREW TYPE, ALLOY AND CYLINDER POSITION ON THE MARGINAL FIT OF IMPLANT FRAMEWORKS BEFORE AND AFTER LASER WELDING
title_fullStr THE INFLUENCE OF SCREW TYPE, ALLOY AND CYLINDER POSITION ON THE MARGINAL FIT OF IMPLANT FRAMEWORKS BEFORE AND AFTER LASER WELDING
title_full_unstemmed THE INFLUENCE OF SCREW TYPE, ALLOY AND CYLINDER POSITION ON THE MARGINAL FIT OF IMPLANT FRAMEWORKS BEFORE AND AFTER LASER WELDING
title_short THE INFLUENCE OF SCREW TYPE, ALLOY AND CYLINDER POSITION ON THE MARGINAL FIT OF IMPLANT FRAMEWORKS BEFORE AND AFTER LASER WELDING
title_sort influence of screw type, alloy and cylinder position on the marginal fit of implant frameworks before and after laser welding
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327446/
https://www.ncbi.nlm.nih.gov/pubmed/19089035
http://dx.doi.org/10.1590/S1678-77572006000200003
work_keys_str_mv AT castiliodaniela theinfluenceofscrewtypealloyandcylinderpositiononthemarginalfitofimplantframeworksbeforeandafterlaserwelding
AT pedreiraanapaularibeirodovale theinfluenceofscrewtypealloyandcylinderpositiononthemarginalfitofimplantframeworksbeforeandafterlaserwelding
AT rossettipaulohenriqueorlato theinfluenceofscrewtypealloyandcylinderpositiononthemarginalfitofimplantframeworksbeforeandafterlaserwelding
AT rossettileylhamarianunes theinfluenceofscrewtypealloyandcylinderpositiononthemarginalfitofimplantframeworksbeforeandafterlaserwelding
AT bonachelawellingtoncardoso theinfluenceofscrewtypealloyandcylinderpositiononthemarginalfitofimplantframeworksbeforeandafterlaserwelding
AT castiliodaniela influenceofscrewtypealloyandcylinderpositiononthemarginalfitofimplantframeworksbeforeandafterlaserwelding
AT pedreiraanapaularibeirodovale influenceofscrewtypealloyandcylinderpositiononthemarginalfitofimplantframeworksbeforeandafterlaserwelding
AT rossettipaulohenriqueorlato influenceofscrewtypealloyandcylinderpositiononthemarginalfitofimplantframeworksbeforeandafterlaserwelding
AT rossettileylhamarianunes influenceofscrewtypealloyandcylinderpositiononthemarginalfitofimplantframeworksbeforeandafterlaserwelding
AT bonachelawellingtoncardoso influenceofscrewtypealloyandcylinderpositiononthemarginalfitofimplantframeworksbeforeandafterlaserwelding