Cargando…

INFLUENCE OF THE DISTANCE OF THE CURING LIGHT SOURCE AND COMPOSITE SHADE ON HARDNESS OF TWO COMPOSITES

This study evaluated the influence of curing tip distance, shade and filler particle size on Vickers microhardness (VHN) of composite resins. Two composites were tested: Filtek Z250 microhybrid (3M ESPE; shades A1 and A3.5) and Filtek Supreme nanofilled (3M ESPE; shades A1B and A3.5B). For each resi...

Descripción completa

Detalles Bibliográficos
Autores principales: Thomé, Thaís, Steagall, Washington, Tachibana, Arlene, Braga, Sheila Regina Maia, Turbino, Miriam Lacalle
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade de Odontologia de Bauru da Universidade de São Paulo 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327496/
https://www.ncbi.nlm.nih.gov/pubmed/19089185
http://dx.doi.org/10.1590/S1678-77572007000600006
_version_ 1782357092876681216
author Thomé, Thaís
Steagall, Washington
Tachibana, Arlene
Braga, Sheila Regina Maia
Turbino, Miriam Lacalle
author_facet Thomé, Thaís
Steagall, Washington
Tachibana, Arlene
Braga, Sheila Regina Maia
Turbino, Miriam Lacalle
author_sort Thomé, Thaís
collection PubMed
description This study evaluated the influence of curing tip distance, shade and filler particle size on Vickers microhardness (VHN) of composite resins. Two composites were tested: Filtek Z250 microhybrid (3M ESPE; shades A1 and A3.5) and Filtek Supreme nanofilled (3M ESPE; shades A1B and A3.5B). For each resin, 42 specimens (5 mm in diameter and 2 mm height) were prepared being 21 for each shade. The specimens were exposed using a 20-second exposure to a quartz-tungsten-halogen light source with an irradiance of approximately 560 mW/cm(2), at the following distances: 0 mm (surface contact), 6 mm and 12 mm from composite surface. Effectiveness of cure of different resins, shades and curing distances was determined by measuring the top and bottom hardness (VHN) of specimens using a digital microhardness tester (load: 50 g; dwell time: 45 seconds) 24 hours following curing. The hardness ratio was calculated by dividing VHN of the bottom surface by VHN of top surface. Three-way ANOVA and Tukey's post-hoc test (p<0.05) revealed statistically significant differences for all analyzed factors. As for top hardness, as microhardness ratio (bottom/top), the factors shade, distance and composite filler particle size exerted influence on resin curing. Lighter shade composites (A1 and A1B) showed higher hardness values. At 6 and 12 mm curing tip distances, hardness was lower when compared to 0 mm. The microhybrid composite resin presented higheer hardness, being its microhardness ratio satisfactory only at 0 mm for both shades and at 6 mm for the lighter shade. The nanofilled composite resin did not present satisfactory microhardness at the bottom while the microhybrid composite resin had higher hardness than the nanofilled. Composite's curing tip distance and shade can influence hardness.
format Online
Article
Text
id pubmed-4327496
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher Faculdade de Odontologia de Bauru da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-43274962015-03-01 INFLUENCE OF THE DISTANCE OF THE CURING LIGHT SOURCE AND COMPOSITE SHADE ON HARDNESS OF TWO COMPOSITES Thomé, Thaís Steagall, Washington Tachibana, Arlene Braga, Sheila Regina Maia Turbino, Miriam Lacalle J Appl Oral Sci Original Article This study evaluated the influence of curing tip distance, shade and filler particle size on Vickers microhardness (VHN) of composite resins. Two composites were tested: Filtek Z250 microhybrid (3M ESPE; shades A1 and A3.5) and Filtek Supreme nanofilled (3M ESPE; shades A1B and A3.5B). For each resin, 42 specimens (5 mm in diameter and 2 mm height) were prepared being 21 for each shade. The specimens were exposed using a 20-second exposure to a quartz-tungsten-halogen light source with an irradiance of approximately 560 mW/cm(2), at the following distances: 0 mm (surface contact), 6 mm and 12 mm from composite surface. Effectiveness of cure of different resins, shades and curing distances was determined by measuring the top and bottom hardness (VHN) of specimens using a digital microhardness tester (load: 50 g; dwell time: 45 seconds) 24 hours following curing. The hardness ratio was calculated by dividing VHN of the bottom surface by VHN of top surface. Three-way ANOVA and Tukey's post-hoc test (p<0.05) revealed statistically significant differences for all analyzed factors. As for top hardness, as microhardness ratio (bottom/top), the factors shade, distance and composite filler particle size exerted influence on resin curing. Lighter shade composites (A1 and A1B) showed higher hardness values. At 6 and 12 mm curing tip distances, hardness was lower when compared to 0 mm. The microhybrid composite resin presented higheer hardness, being its microhardness ratio satisfactory only at 0 mm for both shades and at 6 mm for the lighter shade. The nanofilled composite resin did not present satisfactory microhardness at the bottom while the microhybrid composite resin had higher hardness than the nanofilled. Composite's curing tip distance and shade can influence hardness. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2007-12 /pmc/articles/PMC4327496/ /pubmed/19089185 http://dx.doi.org/10.1590/S1678-77572007000600006 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Thomé, Thaís
Steagall, Washington
Tachibana, Arlene
Braga, Sheila Regina Maia
Turbino, Miriam Lacalle
INFLUENCE OF THE DISTANCE OF THE CURING LIGHT SOURCE AND COMPOSITE SHADE ON HARDNESS OF TWO COMPOSITES
title INFLUENCE OF THE DISTANCE OF THE CURING LIGHT SOURCE AND COMPOSITE SHADE ON HARDNESS OF TWO COMPOSITES
title_full INFLUENCE OF THE DISTANCE OF THE CURING LIGHT SOURCE AND COMPOSITE SHADE ON HARDNESS OF TWO COMPOSITES
title_fullStr INFLUENCE OF THE DISTANCE OF THE CURING LIGHT SOURCE AND COMPOSITE SHADE ON HARDNESS OF TWO COMPOSITES
title_full_unstemmed INFLUENCE OF THE DISTANCE OF THE CURING LIGHT SOURCE AND COMPOSITE SHADE ON HARDNESS OF TWO COMPOSITES
title_short INFLUENCE OF THE DISTANCE OF THE CURING LIGHT SOURCE AND COMPOSITE SHADE ON HARDNESS OF TWO COMPOSITES
title_sort influence of the distance of the curing light source and composite shade on hardness of two composites
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327496/
https://www.ncbi.nlm.nih.gov/pubmed/19089185
http://dx.doi.org/10.1590/S1678-77572007000600006
work_keys_str_mv AT thomethais influenceofthedistanceofthecuringlightsourceandcompositeshadeonhardnessoftwocomposites
AT steagallwashington influenceofthedistanceofthecuringlightsourceandcompositeshadeonhardnessoftwocomposites
AT tachibanaarlene influenceofthedistanceofthecuringlightsourceandcompositeshadeonhardnessoftwocomposites
AT bragasheilareginamaia influenceofthedistanceofthecuringlightsourceandcompositeshadeonhardnessoftwocomposites
AT turbinomiriamlacalle influenceofthedistanceofthecuringlightsourceandcompositeshadeonhardnessoftwocomposites