Visually Evoked Potentials in a Patient with a Fyodorov-Zuev Keratoprosthesis

PURPOSE: To describe a visually evoked potential (VEP) examination performed on a patient with a keratoprosthesis. METHODS: We report the case of a 60-year-old patient with a Fyodorov-Zuev keratoprosthesis in the right eye complained of gradual visual deterioration in that eye. His past medical hist...

Descripción completa

Detalles Bibliográficos
Autores principales: Schwartz, Roy, Barak, Adiel, Newman, Hadas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: S. Karger AG 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327547/
https://www.ncbi.nlm.nih.gov/pubmed/25759664
http://dx.doi.org/10.1159/000369579
Descripción
Sumario:PURPOSE: To describe a visually evoked potential (VEP) examination performed on a patient with a keratoprosthesis. METHODS: We report the case of a 60-year-old patient with a Fyodorov-Zuev keratoprosthesis in the right eye complained of gradual visual deterioration in that eye. His past medical history consisted of failed corneal graft procedures due to corneal dystrophy and an Ahmed valve implantation due to secondary glaucoma. A clinical examination and an ultrasound demonstrated vitreal opacities. In order to assess the visual status, a flash VEP test was conducted. RESULTS: VEP recorded from the right eye consisted of a broadened and poorly formed positive P1 wave, with a subnormal amplitude, but a normal latency. Consequently, the patient underwent a pars plana vitrectomy. CONCLUSION: This case demonstrates the viability of VEP exams in patients with keratoprostheses.