Cargando…
INFLUENCE OF LIGHT ENERGY DENSITY ON HEAT GENERATION DURING PHOTOACTIVATION OF DENTAL COMPOSITES WITH DIFFERENT DENTIN AND COMPOSITE THICKNESS
OBJECTIVE: The aim of this study was to determine the influence of different energy densities on the heat generated during photoactivation of Filtek Z250 (3M/ESPE) and Z100 (3M/ESPE) composite resins with different dentin and composite thickness. MATERIAL AND METHODS: The temperature increase was re...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Faculdade de Odontologia de Bauru da Universidade de São Paulo
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327644/ https://www.ncbi.nlm.nih.gov/pubmed/19668987 http://dx.doi.org/10.1590/S1678-77572009000400005 |
_version_ | 1782357128307015680 |
---|---|
author | Guiraldo, Ricardo Danil Consani, Simonides de Souza, Aline Simprine Consani, Rafael Leonardo Xediek Sinhoreti, Mario Alexandre Coelho Correr, Lourenço |
author_facet | Guiraldo, Ricardo Danil Consani, Simonides de Souza, Aline Simprine Consani, Rafael Leonardo Xediek Sinhoreti, Mario Alexandre Coelho Correr, Lourenço |
author_sort | Guiraldo, Ricardo Danil |
collection | PubMed |
description | OBJECTIVE: The aim of this study was to determine the influence of different energy densities on the heat generated during photoactivation of Filtek Z250 (3M/ESPE) and Z100 (3M/ESPE) composite resins with different dentin and composite thickness. MATERIAL AND METHODS: The temperature increase was registered with a type-K thermocouple connected to a digital thermometer (Iopetherm 46). A chemically polymerized acrylic resin base was prepared to serve as a guide for the thermocouple and as a support for 0.5-, 1.0-, and 1.5-mm-thick bovine dentin discs. Circular elastomer molds (1.0 mm-height x 3.0-mm diameter or 2.0-mm height x 3.0-mm diameter) were adapted on the acrylic resin base to standardize the composite resin thickness. A conventional halogen light-curing unit (XL 2500, 3M/ESPE) was used with light intensity of 700 mW/cm(2). Energy density was calculated by the light intensity applied during a certain time with values of 28 J/cm(2) for Z100 and 14 J/cm(2) for Filtek Z250. The temperature change data were subjected to three-way ANOVA and Tukey's test at 5% level. RESULTS: The higher energy density (Z100) promoted greater temperature increase (p<0.05) than the lower energy density (Filtek Z250). For both composites and all composite thicknesses, the lowest dentin thickness (0.5 mm) yielded significantly higher (p<0.05) temperature increase than the other two dentin thicknesses. The 1-mm-thick composite resin layer yielded significantly higher (p<0.05) temperature changes for both composites and all dentin thicknesses. CONCLUSIONS: Temperature increase was influenced by higher energy density and dentin/composite thickness. |
format | Online Article Text |
id | pubmed-4327644 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Faculdade de Odontologia de Bauru da Universidade de São Paulo |
record_format | MEDLINE/PubMed |
spelling | pubmed-43276442015-04-17 INFLUENCE OF LIGHT ENERGY DENSITY ON HEAT GENERATION DURING PHOTOACTIVATION OF DENTAL COMPOSITES WITH DIFFERENT DENTIN AND COMPOSITE THICKNESS Guiraldo, Ricardo Danil Consani, Simonides de Souza, Aline Simprine Consani, Rafael Leonardo Xediek Sinhoreti, Mario Alexandre Coelho Correr, Lourenço J Appl Oral Sci Original Article OBJECTIVE: The aim of this study was to determine the influence of different energy densities on the heat generated during photoactivation of Filtek Z250 (3M/ESPE) and Z100 (3M/ESPE) composite resins with different dentin and composite thickness. MATERIAL AND METHODS: The temperature increase was registered with a type-K thermocouple connected to a digital thermometer (Iopetherm 46). A chemically polymerized acrylic resin base was prepared to serve as a guide for the thermocouple and as a support for 0.5-, 1.0-, and 1.5-mm-thick bovine dentin discs. Circular elastomer molds (1.0 mm-height x 3.0-mm diameter or 2.0-mm height x 3.0-mm diameter) were adapted on the acrylic resin base to standardize the composite resin thickness. A conventional halogen light-curing unit (XL 2500, 3M/ESPE) was used with light intensity of 700 mW/cm(2). Energy density was calculated by the light intensity applied during a certain time with values of 28 J/cm(2) for Z100 and 14 J/cm(2) for Filtek Z250. The temperature change data were subjected to three-way ANOVA and Tukey's test at 5% level. RESULTS: The higher energy density (Z100) promoted greater temperature increase (p<0.05) than the lower energy density (Filtek Z250). For both composites and all composite thicknesses, the lowest dentin thickness (0.5 mm) yielded significantly higher (p<0.05) temperature increase than the other two dentin thicknesses. The 1-mm-thick composite resin layer yielded significantly higher (p<0.05) temperature changes for both composites and all dentin thicknesses. CONCLUSIONS: Temperature increase was influenced by higher energy density and dentin/composite thickness. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2009-08 /pmc/articles/PMC4327644/ /pubmed/19668987 http://dx.doi.org/10.1590/S1678-77572009000400005 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Guiraldo, Ricardo Danil Consani, Simonides de Souza, Aline Simprine Consani, Rafael Leonardo Xediek Sinhoreti, Mario Alexandre Coelho Correr, Lourenço INFLUENCE OF LIGHT ENERGY DENSITY ON HEAT GENERATION DURING PHOTOACTIVATION OF DENTAL COMPOSITES WITH DIFFERENT DENTIN AND COMPOSITE THICKNESS |
title | INFLUENCE OF LIGHT ENERGY DENSITY ON HEAT GENERATION DURING PHOTOACTIVATION OF DENTAL COMPOSITES WITH DIFFERENT DENTIN AND COMPOSITE THICKNESS |
title_full | INFLUENCE OF LIGHT ENERGY DENSITY ON HEAT GENERATION DURING PHOTOACTIVATION OF DENTAL COMPOSITES WITH DIFFERENT DENTIN AND COMPOSITE THICKNESS |
title_fullStr | INFLUENCE OF LIGHT ENERGY DENSITY ON HEAT GENERATION DURING PHOTOACTIVATION OF DENTAL COMPOSITES WITH DIFFERENT DENTIN AND COMPOSITE THICKNESS |
title_full_unstemmed | INFLUENCE OF LIGHT ENERGY DENSITY ON HEAT GENERATION DURING PHOTOACTIVATION OF DENTAL COMPOSITES WITH DIFFERENT DENTIN AND COMPOSITE THICKNESS |
title_short | INFLUENCE OF LIGHT ENERGY DENSITY ON HEAT GENERATION DURING PHOTOACTIVATION OF DENTAL COMPOSITES WITH DIFFERENT DENTIN AND COMPOSITE THICKNESS |
title_sort | influence of light energy density on heat generation during photoactivation of dental composites with different dentin and composite thickness |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327644/ https://www.ncbi.nlm.nih.gov/pubmed/19668987 http://dx.doi.org/10.1590/S1678-77572009000400005 |
work_keys_str_mv | AT guiraldoricardodanil influenceoflightenergydensityonheatgenerationduringphotoactivationofdentalcompositeswithdifferentdentinandcompositethickness AT consanisimonides influenceoflightenergydensityonheatgenerationduringphotoactivationofdentalcompositeswithdifferentdentinandcompositethickness AT desouzaalinesimprine influenceoflightenergydensityonheatgenerationduringphotoactivationofdentalcompositeswithdifferentdentinandcompositethickness AT consanirafaelleonardoxediek influenceoflightenergydensityonheatgenerationduringphotoactivationofdentalcompositeswithdifferentdentinandcompositethickness AT sinhoretimarioalexandrecoelho influenceoflightenergydensityonheatgenerationduringphotoactivationofdentalcompositeswithdifferentdentinandcompositethickness AT correrlourenco influenceoflightenergydensityonheatgenerationduringphotoactivationofdentalcompositeswithdifferentdentinandcompositethickness |