Cargando…

EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM

Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. Objective: The aim of the present study was to investigate if temperature variation...

Descripción completa

Detalles Bibliográficos
Autores principales: Faria, Adriana Cláudia Lapria, Rodrigues, Renata Cristina Silveira, Antunes, Rossana Pereira de Almeida, de Mattos, Maria da Gloria Chiarello, Rosa, Adalberto Luiz, Ribeiro, Ricardo Faria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade de Odontologia de Bauru da Universidade de São Paulo 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327667/
https://www.ncbi.nlm.nih.gov/pubmed/19936519
http://dx.doi.org/10.1590/S1678-77572009000500013
_version_ 1782357133653704704
author Faria, Adriana Cláudia Lapria
Rodrigues, Renata Cristina Silveira
Antunes, Rossana Pereira de Almeida
de Mattos, Maria da Gloria Chiarello
Rosa, Adalberto Luiz
Ribeiro, Ricardo Faria
author_facet Faria, Adriana Cláudia Lapria
Rodrigues, Renata Cristina Silveira
Antunes, Rossana Pereira de Almeida
de Mattos, Maria da Gloria Chiarello
Rosa, Adalberto Luiz
Ribeiro, Ricardo Faria
author_sort Faria, Adriana Cláudia Lapria
collection PubMed
description Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. Objective: The aim of the present study was to investigate if temperature variation could affect dental alloy cytotoxicity, testing alloy extracts in an epithelial cell culture system. Material and methods: Discs of Ni-Cr, Co-Cr-Mo, Ni-Cr-Ti, Ti-6Al-4V and commercially pure titanium (cp Ti) were cast by arc melting, under argon atmosphere, injected by vacuum-pressure. Discs were immersed in artificial saliva and subjected to different temperatures: 37°C and thermocycling (37°C/5°C/37°C/55°C/37°C). After thermocycling, extracts were put in a subconfluent culture during 6 h, and the number of cells and their viability were used to evaluate cytotoxicity in these temperatures. For each alloy, data from temperature conditions were compared by Student's t-test (α=0.05). Results: The cytotoxicity tests with alloy/metal extracts showed that Ni-Cr, Co-Cr-Mo, Ti-6Al-4V and cp Ti extracts (p>0.05) did not affect cell number or cell viability, while Ni-Cr-Ti (p<0.05) extract decreased cell number and viability when the alloy was subjected to thermocycling. Conclusion: Within the limitations of the present study, the Ni-Cr-Ti alloy had cell number and viability decreased when subjected to temperature variation, while the other alloys/metal extracts did not show these results.
format Online
Article
Text
id pubmed-4327667
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Faculdade de Odontologia de Bauru da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-43276672015-03-11 EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM Faria, Adriana Cláudia Lapria Rodrigues, Renata Cristina Silveira Antunes, Rossana Pereira de Almeida de Mattos, Maria da Gloria Chiarello Rosa, Adalberto Luiz Ribeiro, Ricardo Faria J Appl Oral Sci Original Article Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. Objective: The aim of the present study was to investigate if temperature variation could affect dental alloy cytotoxicity, testing alloy extracts in an epithelial cell culture system. Material and methods: Discs of Ni-Cr, Co-Cr-Mo, Ni-Cr-Ti, Ti-6Al-4V and commercially pure titanium (cp Ti) were cast by arc melting, under argon atmosphere, injected by vacuum-pressure. Discs were immersed in artificial saliva and subjected to different temperatures: 37°C and thermocycling (37°C/5°C/37°C/55°C/37°C). After thermocycling, extracts were put in a subconfluent culture during 6 h, and the number of cells and their viability were used to evaluate cytotoxicity in these temperatures. For each alloy, data from temperature conditions were compared by Student's t-test (α=0.05). Results: The cytotoxicity tests with alloy/metal extracts showed that Ni-Cr, Co-Cr-Mo, Ti-6Al-4V and cp Ti extracts (p>0.05) did not affect cell number or cell viability, while Ni-Cr-Ti (p<0.05) extract decreased cell number and viability when the alloy was subjected to thermocycling. Conclusion: Within the limitations of the present study, the Ni-Cr-Ti alloy had cell number and viability decreased when subjected to temperature variation, while the other alloys/metal extracts did not show these results. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2009-10 /pmc/articles/PMC4327667/ /pubmed/19936519 http://dx.doi.org/10.1590/S1678-77572009000500013 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Faria, Adriana Cláudia Lapria
Rodrigues, Renata Cristina Silveira
Antunes, Rossana Pereira de Almeida
de Mattos, Maria da Gloria Chiarello
Rosa, Adalberto Luiz
Ribeiro, Ricardo Faria
EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM
title EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM
title_full EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM
title_fullStr EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM
title_full_unstemmed EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM
title_short EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM
title_sort effect of temperature variation on the cytotoxicity of cast dental alloys and commercially pure titanium
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327667/
https://www.ncbi.nlm.nih.gov/pubmed/19936519
http://dx.doi.org/10.1590/S1678-77572009000500013
work_keys_str_mv AT fariaadrianaclaudialapria effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium
AT rodriguesrenatacristinasilveira effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium
AT antunesrossanapereiradealmeida effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium
AT demattosmariadagloriachiarello effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium
AT rosaadalbertoluiz effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium
AT ribeiroricardofaria effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium