Cargando…
EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM
Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. Objective: The aim of the present study was to investigate if temperature variation...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Faculdade de Odontologia de Bauru da Universidade de São Paulo
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327667/ https://www.ncbi.nlm.nih.gov/pubmed/19936519 http://dx.doi.org/10.1590/S1678-77572009000500013 |
_version_ | 1782357133653704704 |
---|---|
author | Faria, Adriana Cláudia Lapria Rodrigues, Renata Cristina Silveira Antunes, Rossana Pereira de Almeida de Mattos, Maria da Gloria Chiarello Rosa, Adalberto Luiz Ribeiro, Ricardo Faria |
author_facet | Faria, Adriana Cláudia Lapria Rodrigues, Renata Cristina Silveira Antunes, Rossana Pereira de Almeida de Mattos, Maria da Gloria Chiarello Rosa, Adalberto Luiz Ribeiro, Ricardo Faria |
author_sort | Faria, Adriana Cláudia Lapria |
collection | PubMed |
description | Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. Objective: The aim of the present study was to investigate if temperature variation could affect dental alloy cytotoxicity, testing alloy extracts in an epithelial cell culture system. Material and methods: Discs of Ni-Cr, Co-Cr-Mo, Ni-Cr-Ti, Ti-6Al-4V and commercially pure titanium (cp Ti) were cast by arc melting, under argon atmosphere, injected by vacuum-pressure. Discs were immersed in artificial saliva and subjected to different temperatures: 37°C and thermocycling (37°C/5°C/37°C/55°C/37°C). After thermocycling, extracts were put in a subconfluent culture during 6 h, and the number of cells and their viability were used to evaluate cytotoxicity in these temperatures. For each alloy, data from temperature conditions were compared by Student's t-test (α=0.05). Results: The cytotoxicity tests with alloy/metal extracts showed that Ni-Cr, Co-Cr-Mo, Ti-6Al-4V and cp Ti extracts (p>0.05) did not affect cell number or cell viability, while Ni-Cr-Ti (p<0.05) extract decreased cell number and viability when the alloy was subjected to thermocycling. Conclusion: Within the limitations of the present study, the Ni-Cr-Ti alloy had cell number and viability decreased when subjected to temperature variation, while the other alloys/metal extracts did not show these results. |
format | Online Article Text |
id | pubmed-4327667 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Faculdade de Odontologia de Bauru da Universidade de São Paulo |
record_format | MEDLINE/PubMed |
spelling | pubmed-43276672015-03-11 EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM Faria, Adriana Cláudia Lapria Rodrigues, Renata Cristina Silveira Antunes, Rossana Pereira de Almeida de Mattos, Maria da Gloria Chiarello Rosa, Adalberto Luiz Ribeiro, Ricardo Faria J Appl Oral Sci Original Article Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. Objective: The aim of the present study was to investigate if temperature variation could affect dental alloy cytotoxicity, testing alloy extracts in an epithelial cell culture system. Material and methods: Discs of Ni-Cr, Co-Cr-Mo, Ni-Cr-Ti, Ti-6Al-4V and commercially pure titanium (cp Ti) were cast by arc melting, under argon atmosphere, injected by vacuum-pressure. Discs were immersed in artificial saliva and subjected to different temperatures: 37°C and thermocycling (37°C/5°C/37°C/55°C/37°C). After thermocycling, extracts were put in a subconfluent culture during 6 h, and the number of cells and their viability were used to evaluate cytotoxicity in these temperatures. For each alloy, data from temperature conditions were compared by Student's t-test (α=0.05). Results: The cytotoxicity tests with alloy/metal extracts showed that Ni-Cr, Co-Cr-Mo, Ti-6Al-4V and cp Ti extracts (p>0.05) did not affect cell number or cell viability, while Ni-Cr-Ti (p<0.05) extract decreased cell number and viability when the alloy was subjected to thermocycling. Conclusion: Within the limitations of the present study, the Ni-Cr-Ti alloy had cell number and viability decreased when subjected to temperature variation, while the other alloys/metal extracts did not show these results. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2009-10 /pmc/articles/PMC4327667/ /pubmed/19936519 http://dx.doi.org/10.1590/S1678-77572009000500013 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Faria, Adriana Cláudia Lapria Rodrigues, Renata Cristina Silveira Antunes, Rossana Pereira de Almeida de Mattos, Maria da Gloria Chiarello Rosa, Adalberto Luiz Ribeiro, Ricardo Faria EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM |
title | EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM |
title_full | EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM |
title_fullStr | EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM |
title_full_unstemmed | EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM |
title_short | EFFECT OF TEMPERATURE VARIATION ON THE CYTOTOXICITY OF CAST DENTAL ALLOYS AND COMMERCIALLY PURE TITANIUM |
title_sort | effect of temperature variation on the cytotoxicity of cast dental alloys and commercially pure titanium |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4327667/ https://www.ncbi.nlm.nih.gov/pubmed/19936519 http://dx.doi.org/10.1590/S1678-77572009000500013 |
work_keys_str_mv | AT fariaadrianaclaudialapria effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium AT rodriguesrenatacristinasilveira effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium AT antunesrossanapereiradealmeida effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium AT demattosmariadagloriachiarello effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium AT rosaadalbertoluiz effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium AT ribeiroricardofaria effectoftemperaturevariationonthecytotoxicityofcastdentalalloysandcommerciallypuretitanium |