Cargando…

Tissue heterogeneity in structure and conductivity contribute to cell survival during irreversible electroporation ablation by “electric field sinks”

Irreversible electroporation (IRE) is an emerging, minimally invasive technique for solid tumors ablation, under clinical investigation for cancer therapy. IRE affects only the cell membrane, killing cells while preserving the extracellular matrix structure. Current reports indicate tumors recurrenc...

Descripción completa

Detalles Bibliográficos
Autores principales: Golberg, Alexander, Bruinsma, Bote G., Uygun, Basak E., Yarmush, Martin L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4329566/
https://www.ncbi.nlm.nih.gov/pubmed/25684630
http://dx.doi.org/10.1038/srep08485
_version_ 1782357451922735104
author Golberg, Alexander
Bruinsma, Bote G.
Uygun, Basak E.
Yarmush, Martin L.
author_facet Golberg, Alexander
Bruinsma, Bote G.
Uygun, Basak E.
Yarmush, Martin L.
author_sort Golberg, Alexander
collection PubMed
description Irreversible electroporation (IRE) is an emerging, minimally invasive technique for solid tumors ablation, under clinical investigation for cancer therapy. IRE affects only the cell membrane, killing cells while preserving the extracellular matrix structure. Current reports indicate tumors recurrence rate after IRE averaging 31% of the cases, of which 10% are local recurrences. The mechanisms for these recurrences are not known and new explanations for incomplete cell death are needed. Using finite elements method for electric field distribution, we show that presence of vascular structures with blood leads to the redistribution of electric fields leading to the areas with more than 60% reduced electric field strength in proximity to large blood vessels and clustered vessel structures. In an in vivo rat model of liver IRE ablation, we show that cells located in the proximity of larger vessel structures and in proximity of clustered vessel structures appear less affected by IRE ablation than cells in the tissue parenchyma or in the proximity of small, more isolated vessels. These findings suggest a role for “electric field sinks” in local tumors recurrences after IRE and emphasize the importance of the precise mapping of the targeted organ structure and conductivity for planning of electroporation procedures.
format Online
Article
Text
id pubmed-4329566
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-43295662015-02-23 Tissue heterogeneity in structure and conductivity contribute to cell survival during irreversible electroporation ablation by “electric field sinks” Golberg, Alexander Bruinsma, Bote G. Uygun, Basak E. Yarmush, Martin L. Sci Rep Article Irreversible electroporation (IRE) is an emerging, minimally invasive technique for solid tumors ablation, under clinical investigation for cancer therapy. IRE affects only the cell membrane, killing cells while preserving the extracellular matrix structure. Current reports indicate tumors recurrence rate after IRE averaging 31% of the cases, of which 10% are local recurrences. The mechanisms for these recurrences are not known and new explanations for incomplete cell death are needed. Using finite elements method for electric field distribution, we show that presence of vascular structures with blood leads to the redistribution of electric fields leading to the areas with more than 60% reduced electric field strength in proximity to large blood vessels and clustered vessel structures. In an in vivo rat model of liver IRE ablation, we show that cells located in the proximity of larger vessel structures and in proximity of clustered vessel structures appear less affected by IRE ablation than cells in the tissue parenchyma or in the proximity of small, more isolated vessels. These findings suggest a role for “electric field sinks” in local tumors recurrences after IRE and emphasize the importance of the precise mapping of the targeted organ structure and conductivity for planning of electroporation procedures. Nature Publishing Group 2015-02-16 /pmc/articles/PMC4329566/ /pubmed/25684630 http://dx.doi.org/10.1038/srep08485 Text en Copyright © 2015, Macmillan Publishers Limited. All rights reserved http://creativecommons.org/licenses/by-nc-sa/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. The images or other third party material in this article are included in the article's Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder in order to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/4.0/
spellingShingle Article
Golberg, Alexander
Bruinsma, Bote G.
Uygun, Basak E.
Yarmush, Martin L.
Tissue heterogeneity in structure and conductivity contribute to cell survival during irreversible electroporation ablation by “electric field sinks”
title Tissue heterogeneity in structure and conductivity contribute to cell survival during irreversible electroporation ablation by “electric field sinks”
title_full Tissue heterogeneity in structure and conductivity contribute to cell survival during irreversible electroporation ablation by “electric field sinks”
title_fullStr Tissue heterogeneity in structure and conductivity contribute to cell survival during irreversible electroporation ablation by “electric field sinks”
title_full_unstemmed Tissue heterogeneity in structure and conductivity contribute to cell survival during irreversible electroporation ablation by “electric field sinks”
title_short Tissue heterogeneity in structure and conductivity contribute to cell survival during irreversible electroporation ablation by “electric field sinks”
title_sort tissue heterogeneity in structure and conductivity contribute to cell survival during irreversible electroporation ablation by “electric field sinks”
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4329566/
https://www.ncbi.nlm.nih.gov/pubmed/25684630
http://dx.doi.org/10.1038/srep08485
work_keys_str_mv AT golbergalexander tissueheterogeneityinstructureandconductivitycontributetocellsurvivalduringirreversibleelectroporationablationbyelectricfieldsinks
AT bruinsmaboteg tissueheterogeneityinstructureandconductivitycontributetocellsurvivalduringirreversibleelectroporationablationbyelectricfieldsinks
AT uygunbasake tissueheterogeneityinstructureandconductivitycontributetocellsurvivalduringirreversibleelectroporationablationbyelectricfieldsinks
AT yarmushmartinl tissueheterogeneityinstructureandconductivitycontributetocellsurvivalduringirreversibleelectroporationablationbyelectricfieldsinks