Swept-sine noise-induced damage as a hearing loss model for preclinical assays

Mouse models are key tools for studying cochlear alterations in noise-induced hearing loss (NIHL) and for evaluating new therapies. Stimuli used to induce deafness in mice are usually white and octave band noises that include very low frequencies, considering the large mouse auditory range. We desig...

Descripción completa

Detalles Bibliográficos
Autores principales: Sanz, Lorena, Murillo-Cuesta, Silvia, Cobo, Pedro, Cediel-Algovia, Rafael, Contreras, Julio, Rivera, Teresa, Varela-Nieto, Isabel, Avendaño, Carlos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4329813/
https://www.ncbi.nlm.nih.gov/pubmed/25762930
http://dx.doi.org/10.3389/fnagi.2015.00007
_version_ 1782357497618628608
author Sanz, Lorena
Murillo-Cuesta, Silvia
Cobo, Pedro
Cediel-Algovia, Rafael
Contreras, Julio
Rivera, Teresa
Varela-Nieto, Isabel
Avendaño, Carlos
author_facet Sanz, Lorena
Murillo-Cuesta, Silvia
Cobo, Pedro
Cediel-Algovia, Rafael
Contreras, Julio
Rivera, Teresa
Varela-Nieto, Isabel
Avendaño, Carlos
author_sort Sanz, Lorena
collection PubMed
description Mouse models are key tools for studying cochlear alterations in noise-induced hearing loss (NIHL) and for evaluating new therapies. Stimuli used to induce deafness in mice are usually white and octave band noises that include very low frequencies, considering the large mouse auditory range. We designed different sound stimuli, enriched in frequencies up to 20 kHz (“violet” noises) to examine their impact on hearing thresholds and cochlear cytoarchitecture after short exposure. In addition, we developed a cytocochleogram to quantitatively assess the ensuing structural degeneration and its functional correlation. Finally, we used this mouse model and cochleogram procedure to evaluate the potential therapeutic effect of transforming growth factor β1 (TGF-β1) inhibitors P17 and P144 on NIHL. CBA mice were exposed to violet swept-sine noise (VS) with different frequency ranges (2–20 or 9–13 kHz) and levels (105 or 120 dB SPL) for 30 min. Mice were evaluated by auditory brainstem response (ABR) and otoacoustic emission tests prior to and 2, 14 and 28 days after noise exposure. Cochlear pathology was assessed with gross histology; hair cell number was estimated by a stereological counting method. Our results indicate that functional and morphological changes induced by VS depend on the sound level and frequency composition. Partial hearing recovery followed the exposure to 105 dB SPL, whereas permanent cochlear damage resulted from the exposure to 120 dB SPL. Exposure to 9–13 kHz noise caused an auditory threshold shift (TS) in those frequencies that correlated with hair cell loss in the corresponding areas of the cochlea that were spotted on the cytocochleogram. In summary, we present mouse models of NIHL, which depending on the sound properties of the noise, cause different degrees of cochlear damage, and could therefore be used to study molecules which are potential players in hearing loss protection and repair.
format Online
Article
Text
id pubmed-4329813
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-43298132015-03-11 Swept-sine noise-induced damage as a hearing loss model for preclinical assays Sanz, Lorena Murillo-Cuesta, Silvia Cobo, Pedro Cediel-Algovia, Rafael Contreras, Julio Rivera, Teresa Varela-Nieto, Isabel Avendaño, Carlos Front Aging Neurosci Neuroscience Mouse models are key tools for studying cochlear alterations in noise-induced hearing loss (NIHL) and for evaluating new therapies. Stimuli used to induce deafness in mice are usually white and octave band noises that include very low frequencies, considering the large mouse auditory range. We designed different sound stimuli, enriched in frequencies up to 20 kHz (“violet” noises) to examine their impact on hearing thresholds and cochlear cytoarchitecture after short exposure. In addition, we developed a cytocochleogram to quantitatively assess the ensuing structural degeneration and its functional correlation. Finally, we used this mouse model and cochleogram procedure to evaluate the potential therapeutic effect of transforming growth factor β1 (TGF-β1) inhibitors P17 and P144 on NIHL. CBA mice were exposed to violet swept-sine noise (VS) with different frequency ranges (2–20 or 9–13 kHz) and levels (105 or 120 dB SPL) for 30 min. Mice were evaluated by auditory brainstem response (ABR) and otoacoustic emission tests prior to and 2, 14 and 28 days after noise exposure. Cochlear pathology was assessed with gross histology; hair cell number was estimated by a stereological counting method. Our results indicate that functional and morphological changes induced by VS depend on the sound level and frequency composition. Partial hearing recovery followed the exposure to 105 dB SPL, whereas permanent cochlear damage resulted from the exposure to 120 dB SPL. Exposure to 9–13 kHz noise caused an auditory threshold shift (TS) in those frequencies that correlated with hair cell loss in the corresponding areas of the cochlea that were spotted on the cytocochleogram. In summary, we present mouse models of NIHL, which depending on the sound properties of the noise, cause different degrees of cochlear damage, and could therefore be used to study molecules which are potential players in hearing loss protection and repair. Frontiers Media S.A. 2015-02-16 /pmc/articles/PMC4329813/ /pubmed/25762930 http://dx.doi.org/10.3389/fnagi.2015.00007 Text en Copyright © 2015 Sanz, Murillo-Cuesta, Cobo, Cediel-Algovia, Contreras, Rivera, Varela-Nieto and Avendaño. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution and reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Sanz, Lorena
Murillo-Cuesta, Silvia
Cobo, Pedro
Cediel-Algovia, Rafael
Contreras, Julio
Rivera, Teresa
Varela-Nieto, Isabel
Avendaño, Carlos
Swept-sine noise-induced damage as a hearing loss model for preclinical assays
title Swept-sine noise-induced damage as a hearing loss model for preclinical assays
title_full Swept-sine noise-induced damage as a hearing loss model for preclinical assays
title_fullStr Swept-sine noise-induced damage as a hearing loss model for preclinical assays
title_full_unstemmed Swept-sine noise-induced damage as a hearing loss model for preclinical assays
title_short Swept-sine noise-induced damage as a hearing loss model for preclinical assays
title_sort swept-sine noise-induced damage as a hearing loss model for preclinical assays
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4329813/
https://www.ncbi.nlm.nih.gov/pubmed/25762930
http://dx.doi.org/10.3389/fnagi.2015.00007
work_keys_str_mv AT sanzlorena sweptsinenoiseinduceddamageasahearinglossmodelforpreclinicalassays
AT murillocuestasilvia sweptsinenoiseinduceddamageasahearinglossmodelforpreclinicalassays
AT cobopedro sweptsinenoiseinduceddamageasahearinglossmodelforpreclinicalassays
AT cedielalgoviarafael sweptsinenoiseinduceddamageasahearinglossmodelforpreclinicalassays
AT contrerasjulio sweptsinenoiseinduceddamageasahearinglossmodelforpreclinicalassays
AT riverateresa sweptsinenoiseinduceddamageasahearinglossmodelforpreclinicalassays
AT varelanietoisabel sweptsinenoiseinduceddamageasahearinglossmodelforpreclinicalassays
AT avendanocarlos sweptsinenoiseinduceddamageasahearinglossmodelforpreclinicalassays