Cargando…

Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus

BACKGROUND: Mathematical modeling of cardiovascular magnetic resonance perfusion data allows absolute quantification of myocardial blood flow. Saturation of left ventricle signal during standard contrast administration can compromise the input function used when applying these models. This saturatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Papanastasiou, Giorgos, Williams, Michelle C, Kershaw, Lucy E, Dweck, Marc R, Alam, Shirjel, Mirsadraee, Saeed, Connell, Martin, Gray, Calum, MacGillivray, Tom, Newby, David E, Semple, Scott IK
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4331385/
https://www.ncbi.nlm.nih.gov/pubmed/25885056
http://dx.doi.org/10.1186/s12968-015-0125-1
_version_ 1782357702929809408
author Papanastasiou, Giorgos
Williams, Michelle C
Kershaw, Lucy E
Dweck, Marc R
Alam, Shirjel
Mirsadraee, Saeed
Connell, Martin
Gray, Calum
MacGillivray, Tom
Newby, David E
Semple, Scott IK
author_facet Papanastasiou, Giorgos
Williams, Michelle C
Kershaw, Lucy E
Dweck, Marc R
Alam, Shirjel
Mirsadraee, Saeed
Connell, Martin
Gray, Calum
MacGillivray, Tom
Newby, David E
Semple, Scott IK
author_sort Papanastasiou, Giorgos
collection PubMed
description BACKGROUND: Mathematical modeling of cardiovascular magnetic resonance perfusion data allows absolute quantification of myocardial blood flow. Saturation of left ventricle signal during standard contrast administration can compromise the input function used when applying these models. This saturation effect is evident during application of standard Fermi models in single bolus perfusion data. Dual bolus injection protocols have been suggested to eliminate saturation but are much less practical in the clinical setting. The distributed parameter model can also be used for absolute quantification but has not been applied in patients with coronary artery disease. We assessed whether distributed parameter modeling might be less dependent on arterial input function saturation than Fermi modeling in healthy volunteers. We validated the accuracy of each model in detecting reduced myocardial blood flow in stenotic vessels versus gold-standard invasive methods. METHODS: Eight healthy subjects were scanned using a dual bolus cardiac perfusion protocol at 3T. We performed both single and dual bolus analysis of these data using the distributed parameter and Fermi models. For the dual bolus analysis, a scaled pre-bolus arterial input function was used. In single bolus analysis, the arterial input function was extracted from the main bolus. We also performed analysis using both models of single bolus data obtained from five patients with coronary artery disease and findings were compared against independent invasive coronary angiography and fractional flow reserve. Statistical significance was defined as two-sided P value < 0.05. RESULTS: Fermi models overestimated myocardial blood flow in healthy volunteers due to arterial input function saturation in single bolus analysis compared to dual bolus analysis (P < 0.05). No difference was observed in these volunteers when applying distributed parameter-myocardial blood flow between single and dual bolus analysis. In patients, distributed parameter modeling was able to detect reduced myocardial blood flow at stress (<2.5 mL/min/mL of tissue) in all 12 stenotic vessels compared to only 9 for Fermi modeling. CONCLUSIONS: Comparison of single bolus versus dual bolus values suggests that distributed parameter modeling is less dependent on arterial input function saturation than Fermi modeling. Distributed parameter modeling showed excellent accuracy in detecting reduced myocardial blood flow in all stenotic vessels. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12968-015-0125-1) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4331385
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-43313852015-02-19 Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus Papanastasiou, Giorgos Williams, Michelle C Kershaw, Lucy E Dweck, Marc R Alam, Shirjel Mirsadraee, Saeed Connell, Martin Gray, Calum MacGillivray, Tom Newby, David E Semple, Scott IK J Cardiovasc Magn Reson Research BACKGROUND: Mathematical modeling of cardiovascular magnetic resonance perfusion data allows absolute quantification of myocardial blood flow. Saturation of left ventricle signal during standard contrast administration can compromise the input function used when applying these models. This saturation effect is evident during application of standard Fermi models in single bolus perfusion data. Dual bolus injection protocols have been suggested to eliminate saturation but are much less practical in the clinical setting. The distributed parameter model can also be used for absolute quantification but has not been applied in patients with coronary artery disease. We assessed whether distributed parameter modeling might be less dependent on arterial input function saturation than Fermi modeling in healthy volunteers. We validated the accuracy of each model in detecting reduced myocardial blood flow in stenotic vessels versus gold-standard invasive methods. METHODS: Eight healthy subjects were scanned using a dual bolus cardiac perfusion protocol at 3T. We performed both single and dual bolus analysis of these data using the distributed parameter and Fermi models. For the dual bolus analysis, a scaled pre-bolus arterial input function was used. In single bolus analysis, the arterial input function was extracted from the main bolus. We also performed analysis using both models of single bolus data obtained from five patients with coronary artery disease and findings were compared against independent invasive coronary angiography and fractional flow reserve. Statistical significance was defined as two-sided P value < 0.05. RESULTS: Fermi models overestimated myocardial blood flow in healthy volunteers due to arterial input function saturation in single bolus analysis compared to dual bolus analysis (P < 0.05). No difference was observed in these volunteers when applying distributed parameter-myocardial blood flow between single and dual bolus analysis. In patients, distributed parameter modeling was able to detect reduced myocardial blood flow at stress (<2.5 mL/min/mL of tissue) in all 12 stenotic vessels compared to only 9 for Fermi modeling. CONCLUSIONS: Comparison of single bolus versus dual bolus values suggests that distributed parameter modeling is less dependent on arterial input function saturation than Fermi modeling. Distributed parameter modeling showed excellent accuracy in detecting reduced myocardial blood flow in all stenotic vessels. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12968-015-0125-1) contains supplementary material, which is available to authorized users. BioMed Central 2015-02-17 /pmc/articles/PMC4331385/ /pubmed/25885056 http://dx.doi.org/10.1186/s12968-015-0125-1 Text en © Papanastasiou et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Papanastasiou, Giorgos
Williams, Michelle C
Kershaw, Lucy E
Dweck, Marc R
Alam, Shirjel
Mirsadraee, Saeed
Connell, Martin
Gray, Calum
MacGillivray, Tom
Newby, David E
Semple, Scott IK
Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus
title Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus
title_full Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus
title_fullStr Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus
title_full_unstemmed Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus
title_short Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus
title_sort measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and fermi models with single and dual bolus
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4331385/
https://www.ncbi.nlm.nih.gov/pubmed/25885056
http://dx.doi.org/10.1186/s12968-015-0125-1
work_keys_str_mv AT papanastasiougiorgos measurementofmyocardialbloodflowbycardiovascularmagneticresonanceperfusioncomparisonofdistributedparameterandfermimodelswithsingleanddualbolus
AT williamsmichellec measurementofmyocardialbloodflowbycardiovascularmagneticresonanceperfusioncomparisonofdistributedparameterandfermimodelswithsingleanddualbolus
AT kershawlucye measurementofmyocardialbloodflowbycardiovascularmagneticresonanceperfusioncomparisonofdistributedparameterandfermimodelswithsingleanddualbolus
AT dweckmarcr measurementofmyocardialbloodflowbycardiovascularmagneticresonanceperfusioncomparisonofdistributedparameterandfermimodelswithsingleanddualbolus
AT alamshirjel measurementofmyocardialbloodflowbycardiovascularmagneticresonanceperfusioncomparisonofdistributedparameterandfermimodelswithsingleanddualbolus
AT mirsadraeesaeed measurementofmyocardialbloodflowbycardiovascularmagneticresonanceperfusioncomparisonofdistributedparameterandfermimodelswithsingleanddualbolus
AT connellmartin measurementofmyocardialbloodflowbycardiovascularmagneticresonanceperfusioncomparisonofdistributedparameterandfermimodelswithsingleanddualbolus
AT graycalum measurementofmyocardialbloodflowbycardiovascularmagneticresonanceperfusioncomparisonofdistributedparameterandfermimodelswithsingleanddualbolus
AT macgillivraytom measurementofmyocardialbloodflowbycardiovascularmagneticresonanceperfusioncomparisonofdistributedparameterandfermimodelswithsingleanddualbolus
AT newbydavide measurementofmyocardialbloodflowbycardiovascularmagneticresonanceperfusioncomparisonofdistributedparameterandfermimodelswithsingleanddualbolus
AT semplescottik measurementofmyocardialbloodflowbycardiovascularmagneticresonanceperfusioncomparisonofdistributedparameterandfermimodelswithsingleanddualbolus