Cargando…

Development and Validation of an Automated Step Ergometer

Laboratory ergometers have high costs, becoming inaccessible for most of the population, hence, it is imperative to develop affordable devices making evaluations like cardiorespiratory fitness feasible and easier. The objective of this study was to develop and validate an Automated Step Ergometer (A...

Descripción completa

Detalles Bibliográficos
Autores principales: de Sousa, Maria do Socorro C., Aniceto, Rodrigo R., Neto, Gabriel R., de Araújo, Ravi C. T., de Sousa, Juliana B. C., Costa, José A. D., Pellegrinotti, Idico L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Akademia Wychowania Fizycznego w Katowicach 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4332170/
https://www.ncbi.nlm.nih.gov/pubmed/25713651
http://dx.doi.org/10.2478/hukin-2014-0096
_version_ 1782357859897442304
author de Sousa, Maria do Socorro C.
Aniceto, Rodrigo R.
Neto, Gabriel R.
de Araújo, Ravi C. T.
de Sousa, Juliana B. C.
Costa, José A. D.
Pellegrinotti, Idico L.
author_facet de Sousa, Maria do Socorro C.
Aniceto, Rodrigo R.
Neto, Gabriel R.
de Araújo, Ravi C. T.
de Sousa, Juliana B. C.
Costa, José A. D.
Pellegrinotti, Idico L.
author_sort de Sousa, Maria do Socorro C.
collection PubMed
description Laboratory ergometers have high costs, becoming inaccessible for most of the population, hence, it is imperative to develop affordable devices making evaluations like cardiorespiratory fitness feasible and easier. The objective of this study was to develop and validate an Automated Step Ergometer (ASE), adjusted according to the height of the subject, for predicting VO2max through a progressive test. The development process was comprised by three steps, the theoretical part, the prototype assembly and further validation. The ASE consists in an elevating platform that makes the step at a higher or lower level as required for testing. The ASE validation was obtained by comparing the values of predicted VO2max (equation) and direct gas analysis on the prototype and on a, treadmill. For the validation process 167 subjects with average age of 31.24 ± 14.38 years, of both genders and different degrees of cardiorespiratory fitness, were randomized and divided by gender and training condition, into untrained (n=106), active (n=24) and trained (n=37) subjects. Each participant performed a progressive test on which the ASE started at the same height (20 cm) for all. Then, according to the subject’s height, it varied to a maximum of 45 cm. Time in each stage and rhythm was chosen in accordance with training condition from lowest to highest (60–180 s; 116–160 bpm, respectively). Data was compared with the student’s t test and ANOVA; correlations were tested with Pearson’s r. The value of α was set at 0.05. No differences were found between the predicted VO2max and the direct gas analysis VO2max, nor between the ASE and treadmill VO2max (p= 0.365) with high correlation between ergometers (r= 0.974). The values for repeatability, reproducibility, and reliability of male and female groups measures were, respectively, 4.08 and 5.02; 0.50 and 1.11; 4.11 and 5.15. The values of internal consistency (Cronbach’s alpha) among measures were all >0.90. It was verified that the ASE prototype was appropriate for a step test, provided valid measures of VO2max and could therefore, be used as an ergometer to measure cardiorespiratory fitness.
format Online
Article
Text
id pubmed-4332170
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Akademia Wychowania Fizycznego w Katowicach
record_format MEDLINE/PubMed
spelling pubmed-43321702015-02-24 Development and Validation of an Automated Step Ergometer de Sousa, Maria do Socorro C. Aniceto, Rodrigo R. Neto, Gabriel R. de Araújo, Ravi C. T. de Sousa, Juliana B. C. Costa, José A. D. Pellegrinotti, Idico L. J Hum Kinet Research Article Laboratory ergometers have high costs, becoming inaccessible for most of the population, hence, it is imperative to develop affordable devices making evaluations like cardiorespiratory fitness feasible and easier. The objective of this study was to develop and validate an Automated Step Ergometer (ASE), adjusted according to the height of the subject, for predicting VO2max through a progressive test. The development process was comprised by three steps, the theoretical part, the prototype assembly and further validation. The ASE consists in an elevating platform that makes the step at a higher or lower level as required for testing. The ASE validation was obtained by comparing the values of predicted VO2max (equation) and direct gas analysis on the prototype and on a, treadmill. For the validation process 167 subjects with average age of 31.24 ± 14.38 years, of both genders and different degrees of cardiorespiratory fitness, were randomized and divided by gender and training condition, into untrained (n=106), active (n=24) and trained (n=37) subjects. Each participant performed a progressive test on which the ASE started at the same height (20 cm) for all. Then, according to the subject’s height, it varied to a maximum of 45 cm. Time in each stage and rhythm was chosen in accordance with training condition from lowest to highest (60–180 s; 116–160 bpm, respectively). Data was compared with the student’s t test and ANOVA; correlations were tested with Pearson’s r. The value of α was set at 0.05. No differences were found between the predicted VO2max and the direct gas analysis VO2max, nor between the ASE and treadmill VO2max (p= 0.365) with high correlation between ergometers (r= 0.974). The values for repeatability, reproducibility, and reliability of male and female groups measures were, respectively, 4.08 and 5.02; 0.50 and 1.11; 4.11 and 5.15. The values of internal consistency (Cronbach’s alpha) among measures were all >0.90. It was verified that the ASE prototype was appropriate for a step test, provided valid measures of VO2max and could therefore, be used as an ergometer to measure cardiorespiratory fitness. Akademia Wychowania Fizycznego w Katowicach 2014-11-12 /pmc/articles/PMC4332170/ /pubmed/25713651 http://dx.doi.org/10.2478/hukin-2014-0096 Text en © Editorial Committee of Journal of Human Kinetics This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Research Article
de Sousa, Maria do Socorro C.
Aniceto, Rodrigo R.
Neto, Gabriel R.
de Araújo, Ravi C. T.
de Sousa, Juliana B. C.
Costa, José A. D.
Pellegrinotti, Idico L.
Development and Validation of an Automated Step Ergometer
title Development and Validation of an Automated Step Ergometer
title_full Development and Validation of an Automated Step Ergometer
title_fullStr Development and Validation of an Automated Step Ergometer
title_full_unstemmed Development and Validation of an Automated Step Ergometer
title_short Development and Validation of an Automated Step Ergometer
title_sort development and validation of an automated step ergometer
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4332170/
https://www.ncbi.nlm.nih.gov/pubmed/25713651
http://dx.doi.org/10.2478/hukin-2014-0096
work_keys_str_mv AT desousamariadosocorroc developmentandvalidationofanautomatedstepergometer
AT anicetorodrigor developmentandvalidationofanautomatedstepergometer
AT netogabrielr developmentandvalidationofanautomatedstepergometer
AT dearaujoravict developmentandvalidationofanautomatedstepergometer
AT desousajulianabc developmentandvalidationofanautomatedstepergometer
AT costajosead developmentandvalidationofanautomatedstepergometer
AT pellegrinottiidicol developmentandvalidationofanautomatedstepergometer