Cargando…
Development and Validation of an Automated Step Ergometer
Laboratory ergometers have high costs, becoming inaccessible for most of the population, hence, it is imperative to develop affordable devices making evaluations like cardiorespiratory fitness feasible and easier. The objective of this study was to develop and validate an Automated Step Ergometer (A...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Akademia Wychowania Fizycznego w Katowicach
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4332170/ https://www.ncbi.nlm.nih.gov/pubmed/25713651 http://dx.doi.org/10.2478/hukin-2014-0096 |
_version_ | 1782357859897442304 |
---|---|
author | de Sousa, Maria do Socorro C. Aniceto, Rodrigo R. Neto, Gabriel R. de Araújo, Ravi C. T. de Sousa, Juliana B. C. Costa, José A. D. Pellegrinotti, Idico L. |
author_facet | de Sousa, Maria do Socorro C. Aniceto, Rodrigo R. Neto, Gabriel R. de Araújo, Ravi C. T. de Sousa, Juliana B. C. Costa, José A. D. Pellegrinotti, Idico L. |
author_sort | de Sousa, Maria do Socorro C. |
collection | PubMed |
description | Laboratory ergometers have high costs, becoming inaccessible for most of the population, hence, it is imperative to develop affordable devices making evaluations like cardiorespiratory fitness feasible and easier. The objective of this study was to develop and validate an Automated Step Ergometer (ASE), adjusted according to the height of the subject, for predicting VO2max through a progressive test. The development process was comprised by three steps, the theoretical part, the prototype assembly and further validation. The ASE consists in an elevating platform that makes the step at a higher or lower level as required for testing. The ASE validation was obtained by comparing the values of predicted VO2max (equation) and direct gas analysis on the prototype and on a, treadmill. For the validation process 167 subjects with average age of 31.24 ± 14.38 years, of both genders and different degrees of cardiorespiratory fitness, were randomized and divided by gender and training condition, into untrained (n=106), active (n=24) and trained (n=37) subjects. Each participant performed a progressive test on which the ASE started at the same height (20 cm) for all. Then, according to the subject’s height, it varied to a maximum of 45 cm. Time in each stage and rhythm was chosen in accordance with training condition from lowest to highest (60–180 s; 116–160 bpm, respectively). Data was compared with the student’s t test and ANOVA; correlations were tested with Pearson’s r. The value of α was set at 0.05. No differences were found between the predicted VO2max and the direct gas analysis VO2max, nor between the ASE and treadmill VO2max (p= 0.365) with high correlation between ergometers (r= 0.974). The values for repeatability, reproducibility, and reliability of male and female groups measures were, respectively, 4.08 and 5.02; 0.50 and 1.11; 4.11 and 5.15. The values of internal consistency (Cronbach’s alpha) among measures were all >0.90. It was verified that the ASE prototype was appropriate for a step test, provided valid measures of VO2max and could therefore, be used as an ergometer to measure cardiorespiratory fitness. |
format | Online Article Text |
id | pubmed-4332170 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Akademia Wychowania Fizycznego w Katowicach |
record_format | MEDLINE/PubMed |
spelling | pubmed-43321702015-02-24 Development and Validation of an Automated Step Ergometer de Sousa, Maria do Socorro C. Aniceto, Rodrigo R. Neto, Gabriel R. de Araújo, Ravi C. T. de Sousa, Juliana B. C. Costa, José A. D. Pellegrinotti, Idico L. J Hum Kinet Research Article Laboratory ergometers have high costs, becoming inaccessible for most of the population, hence, it is imperative to develop affordable devices making evaluations like cardiorespiratory fitness feasible and easier. The objective of this study was to develop and validate an Automated Step Ergometer (ASE), adjusted according to the height of the subject, for predicting VO2max through a progressive test. The development process was comprised by three steps, the theoretical part, the prototype assembly and further validation. The ASE consists in an elevating platform that makes the step at a higher or lower level as required for testing. The ASE validation was obtained by comparing the values of predicted VO2max (equation) and direct gas analysis on the prototype and on a, treadmill. For the validation process 167 subjects with average age of 31.24 ± 14.38 years, of both genders and different degrees of cardiorespiratory fitness, were randomized and divided by gender and training condition, into untrained (n=106), active (n=24) and trained (n=37) subjects. Each participant performed a progressive test on which the ASE started at the same height (20 cm) for all. Then, according to the subject’s height, it varied to a maximum of 45 cm. Time in each stage and rhythm was chosen in accordance with training condition from lowest to highest (60–180 s; 116–160 bpm, respectively). Data was compared with the student’s t test and ANOVA; correlations were tested with Pearson’s r. The value of α was set at 0.05. No differences were found between the predicted VO2max and the direct gas analysis VO2max, nor between the ASE and treadmill VO2max (p= 0.365) with high correlation between ergometers (r= 0.974). The values for repeatability, reproducibility, and reliability of male and female groups measures were, respectively, 4.08 and 5.02; 0.50 and 1.11; 4.11 and 5.15. The values of internal consistency (Cronbach’s alpha) among measures were all >0.90. It was verified that the ASE prototype was appropriate for a step test, provided valid measures of VO2max and could therefore, be used as an ergometer to measure cardiorespiratory fitness. Akademia Wychowania Fizycznego w Katowicach 2014-11-12 /pmc/articles/PMC4332170/ /pubmed/25713651 http://dx.doi.org/10.2478/hukin-2014-0096 Text en © Editorial Committee of Journal of Human Kinetics This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Research Article de Sousa, Maria do Socorro C. Aniceto, Rodrigo R. Neto, Gabriel R. de Araújo, Ravi C. T. de Sousa, Juliana B. C. Costa, José A. D. Pellegrinotti, Idico L. Development and Validation of an Automated Step Ergometer |
title | Development and Validation of an Automated Step Ergometer |
title_full | Development and Validation of an Automated Step Ergometer |
title_fullStr | Development and Validation of an Automated Step Ergometer |
title_full_unstemmed | Development and Validation of an Automated Step Ergometer |
title_short | Development and Validation of an Automated Step Ergometer |
title_sort | development and validation of an automated step ergometer |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4332170/ https://www.ncbi.nlm.nih.gov/pubmed/25713651 http://dx.doi.org/10.2478/hukin-2014-0096 |
work_keys_str_mv | AT desousamariadosocorroc developmentandvalidationofanautomatedstepergometer AT anicetorodrigor developmentandvalidationofanautomatedstepergometer AT netogabrielr developmentandvalidationofanautomatedstepergometer AT dearaujoravict developmentandvalidationofanautomatedstepergometer AT desousajulianabc developmentandvalidationofanautomatedstepergometer AT costajosead developmentandvalidationofanautomatedstepergometer AT pellegrinottiidicol developmentandvalidationofanautomatedstepergometer |