Cargando…
Simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis
PURPOSE: To determine the biomechanical response of an impacting airbag on eyes with different axial lengths with transsclerally fixated posterior chamber intraocular lens (PC IOL). MATERIALS AND METHODS: Simulations in a model human eye were performed with a computer using a finite element analysis...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4332257/ https://www.ncbi.nlm.nih.gov/pubmed/25709387 http://dx.doi.org/10.2147/OPTH.S75180 |
_version_ | 1782357881421561856 |
---|---|
author | Huang, Jane Uchio, Eiichi Goto, Satoru |
author_facet | Huang, Jane Uchio, Eiichi Goto, Satoru |
author_sort | Huang, Jane |
collection | PubMed |
description | PURPOSE: To determine the biomechanical response of an impacting airbag on eyes with different axial lengths with transsclerally fixated posterior chamber intraocular lens (PC IOL). MATERIALS AND METHODS: Simulations in a model human eye were performed with a computer using a finite element analysis program created by Nihon, ESI Group. The airbag was set to be deployed at five different velocities and to impact on eyes with three different axial lengths. These eyes were set to have transsclerally fixated PC IOL by a 10-0 polypropylene possessing a tensile force limit of 0.16 N according to the United States Pharmacopeia XXII. RESULTS: The corneoscleral opening was observed at a speed of 40 m/second or more in all model eyes. Eyes with the longest axial length of 25.85 mm had the greatest extent of deformity at any given impact velocity. The impact force exceeded the tensile force of 10-0 polypropylene at an impact velocity of 60 m/second in all eyes, causing breakage of the suture. CONCLUSION: Eyes with transsclerally fixated PC IOL could rupture from airbag impact at high velocities. Eyes with long axial lengths experienced a greater deformity upon airbag impact due to a thinner eye wall. Further basic research on the biomechanical response for assessing eye injuries could help in developing a better airbag and in the further understanding of ocular traumas. |
format | Online Article Text |
id | pubmed-4332257 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-43322572015-02-23 Simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis Huang, Jane Uchio, Eiichi Goto, Satoru Clin Ophthalmol Original Research PURPOSE: To determine the biomechanical response of an impacting airbag on eyes with different axial lengths with transsclerally fixated posterior chamber intraocular lens (PC IOL). MATERIALS AND METHODS: Simulations in a model human eye were performed with a computer using a finite element analysis program created by Nihon, ESI Group. The airbag was set to be deployed at five different velocities and to impact on eyes with three different axial lengths. These eyes were set to have transsclerally fixated PC IOL by a 10-0 polypropylene possessing a tensile force limit of 0.16 N according to the United States Pharmacopeia XXII. RESULTS: The corneoscleral opening was observed at a speed of 40 m/second or more in all model eyes. Eyes with the longest axial length of 25.85 mm had the greatest extent of deformity at any given impact velocity. The impact force exceeded the tensile force of 10-0 polypropylene at an impact velocity of 60 m/second in all eyes, causing breakage of the suture. CONCLUSION: Eyes with transsclerally fixated PC IOL could rupture from airbag impact at high velocities. Eyes with long axial lengths experienced a greater deformity upon airbag impact due to a thinner eye wall. Further basic research on the biomechanical response for assessing eye injuries could help in developing a better airbag and in the further understanding of ocular traumas. Dove Medical Press 2015-02-05 /pmc/articles/PMC4332257/ /pubmed/25709387 http://dx.doi.org/10.2147/OPTH.S75180 Text en © 2015 Huang et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Huang, Jane Uchio, Eiichi Goto, Satoru Simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis |
title | Simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis |
title_full | Simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis |
title_fullStr | Simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis |
title_full_unstemmed | Simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis |
title_short | Simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis |
title_sort | simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4332257/ https://www.ncbi.nlm.nih.gov/pubmed/25709387 http://dx.doi.org/10.2147/OPTH.S75180 |
work_keys_str_mv | AT huangjane simulationofairbagimpactoneyeswithdifferentaxiallengthsaftertranssclerallyfixatedposteriorchamberintraocularlensbyusingfiniteelementanalysis AT uchioeiichi simulationofairbagimpactoneyeswithdifferentaxiallengthsaftertranssclerallyfixatedposteriorchamberintraocularlensbyusingfiniteelementanalysis AT gotosatoru simulationofairbagimpactoneyeswithdifferentaxiallengthsaftertranssclerallyfixatedposteriorchamberintraocularlensbyusingfiniteelementanalysis |