Cargando…
Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0
This synopsis outlines the Japanese guideline Version 2.0 for the data acquisition protocol of oncology FDG-PET/CT scans that was created by a joint task force of the Japanese Society of Nuclear Medicine Technology, the Japanese Society of Nuclear Medicine and the Japanese Council of PET Imaging, an...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Japan
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4332454/ https://www.ncbi.nlm.nih.gov/pubmed/24859759 http://dx.doi.org/10.1007/s12149-014-0849-2 |
_version_ | 1782357914822901760 |
---|---|
author | Fukukita, Hiroyoshi Suzuki, Kazufumi Matsumoto, Keiichi Terauchi, Takashi Daisaki, Hiromitsu Ikari, Yasuhiko Shimada, Naoki Senda, Michio |
author_facet | Fukukita, Hiroyoshi Suzuki, Kazufumi Matsumoto, Keiichi Terauchi, Takashi Daisaki, Hiromitsu Ikari, Yasuhiko Shimada, Naoki Senda, Michio |
author_sort | Fukukita, Hiroyoshi |
collection | PubMed |
description | This synopsis outlines the Japanese guideline Version 2.0 for the data acquisition protocol of oncology FDG-PET/CT scans that was created by a joint task force of the Japanese Society of Nuclear Medicine Technology, the Japanese Society of Nuclear Medicine and the Japanese Council of PET Imaging, and was published in Kakuigaku-Gijutsu 2013; 33:377–420 in Japanese. The guideline aims at standardizing the PET image quality among PET centers and different PET camera models by providing criteria for the IEC body phantom image quality as well as for the patient PET image quality based on the noise equivalent count (NEC), NEC density and liver signal-to-noise ratio, so that the appropriate scanning parameters can be determined for each PET camera. This Version 2.0 covers issues that were not focused on in Version 1.0, including the accuracy of the standardized uptake value (SUV), effect of body size together with adjustment of scanning duration, and time-of-flight (TOF) reconstruction technique. Version 2.0 also presents data acquired with new PET camera models that were not tested in Version 1.0. Reference values for physical indicators of phantom image quality have been updated as well. |
format | Online Article Text |
id | pubmed-4332454 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer Japan |
record_format | MEDLINE/PubMed |
spelling | pubmed-43324542015-02-20 Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0 Fukukita, Hiroyoshi Suzuki, Kazufumi Matsumoto, Keiichi Terauchi, Takashi Daisaki, Hiromitsu Ikari, Yasuhiko Shimada, Naoki Senda, Michio Ann Nucl Med Others This synopsis outlines the Japanese guideline Version 2.0 for the data acquisition protocol of oncology FDG-PET/CT scans that was created by a joint task force of the Japanese Society of Nuclear Medicine Technology, the Japanese Society of Nuclear Medicine and the Japanese Council of PET Imaging, and was published in Kakuigaku-Gijutsu 2013; 33:377–420 in Japanese. The guideline aims at standardizing the PET image quality among PET centers and different PET camera models by providing criteria for the IEC body phantom image quality as well as for the patient PET image quality based on the noise equivalent count (NEC), NEC density and liver signal-to-noise ratio, so that the appropriate scanning parameters can be determined for each PET camera. This Version 2.0 covers issues that were not focused on in Version 1.0, including the accuracy of the standardized uptake value (SUV), effect of body size together with adjustment of scanning duration, and time-of-flight (TOF) reconstruction technique. Version 2.0 also presents data acquired with new PET camera models that were not tested in Version 1.0. Reference values for physical indicators of phantom image quality have been updated as well. Springer Japan 2014-05-24 2014 /pmc/articles/PMC4332454/ /pubmed/24859759 http://dx.doi.org/10.1007/s12149-014-0849-2 Text en © The Japanese Society of Nuclear Medicine 2014 |
spellingShingle | Others Fukukita, Hiroyoshi Suzuki, Kazufumi Matsumoto, Keiichi Terauchi, Takashi Daisaki, Hiromitsu Ikari, Yasuhiko Shimada, Naoki Senda, Michio Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0 |
title | Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0 |
title_full | Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0 |
title_fullStr | Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0 |
title_full_unstemmed | Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0 |
title_short | Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0 |
title_sort | japanese guideline for the oncology fdg-pet/ct data acquisition protocol: synopsis of version 2.0 |
topic | Others |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4332454/ https://www.ncbi.nlm.nih.gov/pubmed/24859759 http://dx.doi.org/10.1007/s12149-014-0849-2 |
work_keys_str_mv | AT fukukitahiroyoshi japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20 AT suzukikazufumi japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20 AT matsumotokeiichi japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20 AT terauchitakashi japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20 AT daisakihiromitsu japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20 AT ikariyasuhiko japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20 AT shimadanaoki japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20 AT sendamichio japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20 |