Cargando…

Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0

This synopsis outlines the Japanese guideline Version 2.0 for the data acquisition protocol of oncology FDG-PET/CT scans that was created by a joint task force of the Japanese Society of Nuclear Medicine Technology, the Japanese Society of Nuclear Medicine and the Japanese Council of PET Imaging, an...

Descripción completa

Detalles Bibliográficos
Autores principales: Fukukita, Hiroyoshi, Suzuki, Kazufumi, Matsumoto, Keiichi, Terauchi, Takashi, Daisaki, Hiromitsu, Ikari, Yasuhiko, Shimada, Naoki, Senda, Michio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Japan 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4332454/
https://www.ncbi.nlm.nih.gov/pubmed/24859759
http://dx.doi.org/10.1007/s12149-014-0849-2
_version_ 1782357914822901760
author Fukukita, Hiroyoshi
Suzuki, Kazufumi
Matsumoto, Keiichi
Terauchi, Takashi
Daisaki, Hiromitsu
Ikari, Yasuhiko
Shimada, Naoki
Senda, Michio
author_facet Fukukita, Hiroyoshi
Suzuki, Kazufumi
Matsumoto, Keiichi
Terauchi, Takashi
Daisaki, Hiromitsu
Ikari, Yasuhiko
Shimada, Naoki
Senda, Michio
author_sort Fukukita, Hiroyoshi
collection PubMed
description This synopsis outlines the Japanese guideline Version 2.0 for the data acquisition protocol of oncology FDG-PET/CT scans that was created by a joint task force of the Japanese Society of Nuclear Medicine Technology, the Japanese Society of Nuclear Medicine and the Japanese Council of PET Imaging, and was published in Kakuigaku-Gijutsu 2013; 33:377–420 in Japanese. The guideline aims at standardizing the PET image quality among PET centers and different PET camera models by providing criteria for the IEC body phantom image quality as well as for the patient PET image quality based on the noise equivalent count (NEC), NEC density and liver signal-to-noise ratio, so that the appropriate scanning parameters can be determined for each PET camera. This Version 2.0 covers issues that were not focused on in Version 1.0, including the accuracy of the standardized uptake value (SUV), effect of body size together with adjustment of scanning duration, and time-of-flight (TOF) reconstruction technique. Version 2.0 also presents data acquired with new PET camera models that were not tested in Version 1.0. Reference values for physical indicators of phantom image quality have been updated as well.
format Online
Article
Text
id pubmed-4332454
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer Japan
record_format MEDLINE/PubMed
spelling pubmed-43324542015-02-20 Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0 Fukukita, Hiroyoshi Suzuki, Kazufumi Matsumoto, Keiichi Terauchi, Takashi Daisaki, Hiromitsu Ikari, Yasuhiko Shimada, Naoki Senda, Michio Ann Nucl Med Others This synopsis outlines the Japanese guideline Version 2.0 for the data acquisition protocol of oncology FDG-PET/CT scans that was created by a joint task force of the Japanese Society of Nuclear Medicine Technology, the Japanese Society of Nuclear Medicine and the Japanese Council of PET Imaging, and was published in Kakuigaku-Gijutsu 2013; 33:377–420 in Japanese. The guideline aims at standardizing the PET image quality among PET centers and different PET camera models by providing criteria for the IEC body phantom image quality as well as for the patient PET image quality based on the noise equivalent count (NEC), NEC density and liver signal-to-noise ratio, so that the appropriate scanning parameters can be determined for each PET camera. This Version 2.0 covers issues that were not focused on in Version 1.0, including the accuracy of the standardized uptake value (SUV), effect of body size together with adjustment of scanning duration, and time-of-flight (TOF) reconstruction technique. Version 2.0 also presents data acquired with new PET camera models that were not tested in Version 1.0. Reference values for physical indicators of phantom image quality have been updated as well. Springer Japan 2014-05-24 2014 /pmc/articles/PMC4332454/ /pubmed/24859759 http://dx.doi.org/10.1007/s12149-014-0849-2 Text en © The Japanese Society of Nuclear Medicine 2014
spellingShingle Others
Fukukita, Hiroyoshi
Suzuki, Kazufumi
Matsumoto, Keiichi
Terauchi, Takashi
Daisaki, Hiromitsu
Ikari, Yasuhiko
Shimada, Naoki
Senda, Michio
Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0
title Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0
title_full Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0
title_fullStr Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0
title_full_unstemmed Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0
title_short Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0
title_sort japanese guideline for the oncology fdg-pet/ct data acquisition protocol: synopsis of version 2.0
topic Others
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4332454/
https://www.ncbi.nlm.nih.gov/pubmed/24859759
http://dx.doi.org/10.1007/s12149-014-0849-2
work_keys_str_mv AT fukukitahiroyoshi japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20
AT suzukikazufumi japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20
AT matsumotokeiichi japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20
AT terauchitakashi japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20
AT daisakihiromitsu japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20
AT ikariyasuhiko japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20
AT shimadanaoki japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20
AT sendamichio japaneseguidelinefortheoncologyfdgpetctdataacquisitionprotocolsynopsisofversion20