Cargando…
(99m)Technetium Sestamibi-(123)Iodine Scintigraphy Is More Accurate Than (99m)Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism
Objectives. Studies comparing outcome of single-(99m)Tc-methoxyisobutylisonitrile ((99m)Tc-sestamibi) and dual-tracer (99m)Tc-sestamibi scintigraphy in combination with (123)I before primary surgery of primary hyperparathyroidism (PHPT) are scarce. Methods. We compared (99m)Tc-sestamibi/(123)I and (...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4333274/ https://www.ncbi.nlm.nih.gov/pubmed/25722888 http://dx.doi.org/10.1155/2015/391625 |
_version_ | 1782358007193010176 |
---|---|
author | Ryhänen, Eeva M. Schildt, Jukka Heiskanen, Ilkka Väisänen, Mika Ahonen, Aapo Löyttyniemi, Eliisa Schalin-Jäntti, Camilla Välimäki, Matti J. |
author_facet | Ryhänen, Eeva M. Schildt, Jukka Heiskanen, Ilkka Väisänen, Mika Ahonen, Aapo Löyttyniemi, Eliisa Schalin-Jäntti, Camilla Välimäki, Matti J. |
author_sort | Ryhänen, Eeva M. |
collection | PubMed |
description | Objectives. Studies comparing outcome of single-(99m)Tc-methoxyisobutylisonitrile ((99m)Tc-sestamibi) and dual-tracer (99m)Tc-sestamibi scintigraphy in combination with (123)I before primary surgery of primary hyperparathyroidism (PHPT) are scarce. Methods. We compared (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi in a single-centre retrospective series of 269 PHPT patients. The results were related to laboratory, surgical and histological findings. Results. (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi were positive in 206 (76.6%) and 111 (41.3%) of 269 patients, respectively (P < 0.001). Accuracies for (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi were 63.4% and 34.9%, respectively (96% CI, P < 0.001). Prevalence of multiglandular disease was 15.2%. In multiglandular disease, (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi revealed 43.8 and 22.1% of pathological glands, respectively (P < 0.001). Cure rate was similar for patients with (191/206; 92.7%) and without (59 of 63; 93.7%) a positive (99m)Tc-sestamibi/(123)I finding. Duration of targeted surgery (one or two quadrants) was 21 and 15 minutes shorter than bilateral neck exploration, respectively (both P < 0.001). Higher serum calcium (P = 0.014) and PTH (P = 0.055) concentrations and larger tumours (P < 0.001) characterized the 206 patients with a positive preoperative scan who were cured by removal of a single adenoma. Conclusions. (99m)Tc-sestamibi/(123)I scintigraphy is more accurate than (99m)Tc-sestamibi before surgery of PHPT. However, outcome of surgery is not determined by scintigraphy alone. |
format | Online Article Text |
id | pubmed-4333274 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-43332742015-02-26 (99m)Technetium Sestamibi-(123)Iodine Scintigraphy Is More Accurate Than (99m)Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism Ryhänen, Eeva M. Schildt, Jukka Heiskanen, Ilkka Väisänen, Mika Ahonen, Aapo Löyttyniemi, Eliisa Schalin-Jäntti, Camilla Välimäki, Matti J. Int J Mol Imaging Research Article Objectives. Studies comparing outcome of single-(99m)Tc-methoxyisobutylisonitrile ((99m)Tc-sestamibi) and dual-tracer (99m)Tc-sestamibi scintigraphy in combination with (123)I before primary surgery of primary hyperparathyroidism (PHPT) are scarce. Methods. We compared (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi in a single-centre retrospective series of 269 PHPT patients. The results were related to laboratory, surgical and histological findings. Results. (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi were positive in 206 (76.6%) and 111 (41.3%) of 269 patients, respectively (P < 0.001). Accuracies for (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi were 63.4% and 34.9%, respectively (96% CI, P < 0.001). Prevalence of multiglandular disease was 15.2%. In multiglandular disease, (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi revealed 43.8 and 22.1% of pathological glands, respectively (P < 0.001). Cure rate was similar for patients with (191/206; 92.7%) and without (59 of 63; 93.7%) a positive (99m)Tc-sestamibi/(123)I finding. Duration of targeted surgery (one or two quadrants) was 21 and 15 minutes shorter than bilateral neck exploration, respectively (both P < 0.001). Higher serum calcium (P = 0.014) and PTH (P = 0.055) concentrations and larger tumours (P < 0.001) characterized the 206 patients with a positive preoperative scan who were cured by removal of a single adenoma. Conclusions. (99m)Tc-sestamibi/(123)I scintigraphy is more accurate than (99m)Tc-sestamibi before surgery of PHPT. However, outcome of surgery is not determined by scintigraphy alone. Hindawi Publishing Corporation 2015 2015-02-01 /pmc/articles/PMC4333274/ /pubmed/25722888 http://dx.doi.org/10.1155/2015/391625 Text en Copyright © 2015 Eeva M. Ryhänen et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Ryhänen, Eeva M. Schildt, Jukka Heiskanen, Ilkka Väisänen, Mika Ahonen, Aapo Löyttyniemi, Eliisa Schalin-Jäntti, Camilla Välimäki, Matti J. (99m)Technetium Sestamibi-(123)Iodine Scintigraphy Is More Accurate Than (99m)Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism |
title |
(99m)Technetium Sestamibi-(123)Iodine Scintigraphy Is More Accurate Than (99m)Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism |
title_full |
(99m)Technetium Sestamibi-(123)Iodine Scintigraphy Is More Accurate Than (99m)Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism |
title_fullStr |
(99m)Technetium Sestamibi-(123)Iodine Scintigraphy Is More Accurate Than (99m)Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism |
title_full_unstemmed |
(99m)Technetium Sestamibi-(123)Iodine Scintigraphy Is More Accurate Than (99m)Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism |
title_short |
(99m)Technetium Sestamibi-(123)Iodine Scintigraphy Is More Accurate Than (99m)Technetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism |
title_sort | (99m)technetium sestamibi-(123)iodine scintigraphy is more accurate than (99m)technetium sestamibi alone before surgery for primary hyperparathyroidism |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4333274/ https://www.ncbi.nlm.nih.gov/pubmed/25722888 http://dx.doi.org/10.1155/2015/391625 |
work_keys_str_mv | AT ryhaneneevam 99mtechnetiumsestamibi123iodinescintigraphyismoreaccuratethan99mtechnetiumsestamibialonebeforesurgeryforprimaryhyperparathyroidism AT schildtjukka 99mtechnetiumsestamibi123iodinescintigraphyismoreaccuratethan99mtechnetiumsestamibialonebeforesurgeryforprimaryhyperparathyroidism AT heiskanenilkka 99mtechnetiumsestamibi123iodinescintigraphyismoreaccuratethan99mtechnetiumsestamibialonebeforesurgeryforprimaryhyperparathyroidism AT vaisanenmika 99mtechnetiumsestamibi123iodinescintigraphyismoreaccuratethan99mtechnetiumsestamibialonebeforesurgeryforprimaryhyperparathyroidism AT ahonenaapo 99mtechnetiumsestamibi123iodinescintigraphyismoreaccuratethan99mtechnetiumsestamibialonebeforesurgeryforprimaryhyperparathyroidism AT loyttyniemieliisa 99mtechnetiumsestamibi123iodinescintigraphyismoreaccuratethan99mtechnetiumsestamibialonebeforesurgeryforprimaryhyperparathyroidism AT schalinjantticamilla 99mtechnetiumsestamibi123iodinescintigraphyismoreaccuratethan99mtechnetiumsestamibialonebeforesurgeryforprimaryhyperparathyroidism AT valimakimattij 99mtechnetiumsestamibi123iodinescintigraphyismoreaccuratethan99mtechnetiumsestamibialonebeforesurgeryforprimaryhyperparathyroidism |