Cargando…
Hemodynamic Parameters of Low-Flow Isoflurane and Low-Flow Sevoflurane Anesthesia During Controlled Ventilation With Laryngeal Mask Airway
BACKGROUND: Nowadays laryngeal mask airway (LMA) is popular as one of the best choices for airway management. Low-flow anesthesia has some advantages like lower pollution, hemodynamic stability and cost effectiveness. Volatile anesthetics are widely used for anesthesia maintenance during operations....
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4333304/ https://www.ncbi.nlm.nih.gov/pubmed/25729676 http://dx.doi.org/10.5812/aapm.20326 |
_version_ | 1782358014219517952 |
---|---|
author | Negargar, Sohrab Peirovifar, Ali Mahmoodpoor, Ata Parish, Masoud Golzari, Samad EJ Molseqi, Haniye Negargar, Soheil |
author_facet | Negargar, Sohrab Peirovifar, Ali Mahmoodpoor, Ata Parish, Masoud Golzari, Samad EJ Molseqi, Haniye Negargar, Soheil |
author_sort | Negargar, Sohrab |
collection | PubMed |
description | BACKGROUND: Nowadays laryngeal mask airway (LMA) is popular as one of the best choices for airway management. Low-flow anesthesia has some advantages like lower pollution, hemodynamic stability and cost effectiveness. Volatile anesthetics are widely used for anesthesia maintenance during operations. Sevoflurane has more hemodynamic stability compared to isoflurane, but there are few studies comparing the hemodynamic stabilities of these two anesthetics during controlled low flow anesthesia with LMA. OBJECTIVES: The aim of this study was to compare the effects of low-flow sevoflurane and low-flow isoflurane on hemodynamic parameters of patients through LMA. PATIENTS AND METHODS: Eighty patients, scheduled for elective ophthalmic surgery, were randomly divided into two groups. After induction, an LMA with an appropriate size was inserted in all the patients and they were randomly allocated to two groups of low-flow sevoflurane (n = 40) and low-flow isoflurane (n = 40). Hemodynamic parameters (heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP) and Mean Arterial Pressure (MAP) were recorded at 5, 10, 15, 20, 25 and 30 minutes after the anesthesia induction. RESULTS: The mean heart rate values were significantly less in the sevoflurane group (P value < 0.05) at 25 minutes after the surgery. The mean Blood Pressure in the isoflurane group was significantly higher compared with the sevoflurane group in 10, 20 and 30 minutes after the surgery (P values = 0.0131, 0.0373 and 0.0028, respectively). These differences were clinically unimportant because heart rate and mean blood pressure were on normal ranges. CONCLUSIONS: Seemingly, low-flow sevoflurane with LMA did not have any significant hemodynamic effect on clinical practice. Therefore, low-flow sevoflurane anesthesia with LMA might be considered in patients with short operations who need rapid recovery from anesthesia. |
format | Online Article Text |
id | pubmed-4333304 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Kowsar |
record_format | MEDLINE/PubMed |
spelling | pubmed-43333042015-02-27 Hemodynamic Parameters of Low-Flow Isoflurane and Low-Flow Sevoflurane Anesthesia During Controlled Ventilation With Laryngeal Mask Airway Negargar, Sohrab Peirovifar, Ali Mahmoodpoor, Ata Parish, Masoud Golzari, Samad EJ Molseqi, Haniye Negargar, Soheil Anesth Pain Med Research Article BACKGROUND: Nowadays laryngeal mask airway (LMA) is popular as one of the best choices for airway management. Low-flow anesthesia has some advantages like lower pollution, hemodynamic stability and cost effectiveness. Volatile anesthetics are widely used for anesthesia maintenance during operations. Sevoflurane has more hemodynamic stability compared to isoflurane, but there are few studies comparing the hemodynamic stabilities of these two anesthetics during controlled low flow anesthesia with LMA. OBJECTIVES: The aim of this study was to compare the effects of low-flow sevoflurane and low-flow isoflurane on hemodynamic parameters of patients through LMA. PATIENTS AND METHODS: Eighty patients, scheduled for elective ophthalmic surgery, were randomly divided into two groups. After induction, an LMA with an appropriate size was inserted in all the patients and they were randomly allocated to two groups of low-flow sevoflurane (n = 40) and low-flow isoflurane (n = 40). Hemodynamic parameters (heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP) and Mean Arterial Pressure (MAP) were recorded at 5, 10, 15, 20, 25 and 30 minutes after the anesthesia induction. RESULTS: The mean heart rate values were significantly less in the sevoflurane group (P value < 0.05) at 25 minutes after the surgery. The mean Blood Pressure in the isoflurane group was significantly higher compared with the sevoflurane group in 10, 20 and 30 minutes after the surgery (P values = 0.0131, 0.0373 and 0.0028, respectively). These differences were clinically unimportant because heart rate and mean blood pressure were on normal ranges. CONCLUSIONS: Seemingly, low-flow sevoflurane with LMA did not have any significant hemodynamic effect on clinical practice. Therefore, low-flow sevoflurane anesthesia with LMA might be considered in patients with short operations who need rapid recovery from anesthesia. Kowsar 2014-12-04 /pmc/articles/PMC4333304/ /pubmed/25729676 http://dx.doi.org/10.5812/aapm.20326 Text en Copyright © 2014, Iranian Society of Regional Anesthesia and Pain Medicine (ISRAPM); Published by Kowsar. http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited. |
spellingShingle | Research Article Negargar, Sohrab Peirovifar, Ali Mahmoodpoor, Ata Parish, Masoud Golzari, Samad EJ Molseqi, Haniye Negargar, Soheil Hemodynamic Parameters of Low-Flow Isoflurane and Low-Flow Sevoflurane Anesthesia During Controlled Ventilation With Laryngeal Mask Airway |
title | Hemodynamic Parameters of Low-Flow Isoflurane and Low-Flow Sevoflurane Anesthesia During Controlled Ventilation With Laryngeal Mask Airway |
title_full | Hemodynamic Parameters of Low-Flow Isoflurane and Low-Flow Sevoflurane Anesthesia During Controlled Ventilation With Laryngeal Mask Airway |
title_fullStr | Hemodynamic Parameters of Low-Flow Isoflurane and Low-Flow Sevoflurane Anesthesia During Controlled Ventilation With Laryngeal Mask Airway |
title_full_unstemmed | Hemodynamic Parameters of Low-Flow Isoflurane and Low-Flow Sevoflurane Anesthesia During Controlled Ventilation With Laryngeal Mask Airway |
title_short | Hemodynamic Parameters of Low-Flow Isoflurane and Low-Flow Sevoflurane Anesthesia During Controlled Ventilation With Laryngeal Mask Airway |
title_sort | hemodynamic parameters of low-flow isoflurane and low-flow sevoflurane anesthesia during controlled ventilation with laryngeal mask airway |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4333304/ https://www.ncbi.nlm.nih.gov/pubmed/25729676 http://dx.doi.org/10.5812/aapm.20326 |
work_keys_str_mv | AT negargarsohrab hemodynamicparametersoflowflowisofluraneandlowflowsevofluraneanesthesiaduringcontrolledventilationwithlaryngealmaskairway AT peirovifarali hemodynamicparametersoflowflowisofluraneandlowflowsevofluraneanesthesiaduringcontrolledventilationwithlaryngealmaskairway AT mahmoodpoorata hemodynamicparametersoflowflowisofluraneandlowflowsevofluraneanesthesiaduringcontrolledventilationwithlaryngealmaskairway AT parishmasoud hemodynamicparametersoflowflowisofluraneandlowflowsevofluraneanesthesiaduringcontrolledventilationwithlaryngealmaskairway AT golzarisamadej hemodynamicparametersoflowflowisofluraneandlowflowsevofluraneanesthesiaduringcontrolledventilationwithlaryngealmaskairway AT molseqihaniye hemodynamicparametersoflowflowisofluraneandlowflowsevofluraneanesthesiaduringcontrolledventilationwithlaryngealmaskairway AT negargarsoheil hemodynamicparametersoflowflowisofluraneandlowflowsevofluraneanesthesiaduringcontrolledventilationwithlaryngealmaskairway |