Cargando…

The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length

BACKGROUND: Increased size of kidney is the main symptom of pyelonephritis and renal ischemia in children. Ultrasound and computed tomography (CT) scan methods are the imaging methods for evaluating the urogenital system. The aim of this study is to compare the kidney length obtained from spiral CT...

Descripción completa

Detalles Bibliográficos
Autores principales: Karami, Mehdi, Rahimi, Farshad, Tajadini, Mohammadhasan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4333429/
https://www.ncbi.nlm.nih.gov/pubmed/25709984
http://dx.doi.org/10.4103/2277-9175.149850
_version_ 1782358041032654848
author Karami, Mehdi
Rahimi, Farshad
Tajadini, Mohammadhasan
author_facet Karami, Mehdi
Rahimi, Farshad
Tajadini, Mohammadhasan
author_sort Karami, Mehdi
collection PubMed
description BACKGROUND: Increased size of kidney is the main symptom of pyelonephritis and renal ischemia in children. Ultrasound and computed tomography (CT) scan methods are the imaging methods for evaluating the urogenital system. The aim of this study is to compare the kidney length obtained from spiral CT scan with the true length obtained from multi-slice CT. MATERIALS AND METHODS: From 100 patients 200 kidneys were examined in Alzahra Hospital in 2012. Multi-slice CT was used to obtain coronal and sagittal cuts to find the length of kidneys. RESULTS: The mean values of true size of axial sections of the right and left kidneys were 108.37 ± 12.3 mm and 109.74 ± 13.6 mm, respectively. The mean difference of axial sections’ lengths in the right and left kidneys was 1.37 ± 1.22 mm. The mean values of length in the spiral CT scan of the right and left kidneys were 98.61 ± 15.8 mm and 103.11 ± 15.9 mm, respectively. The difference in the estimated size by multi-slice CT scan in oblique and axial images was significant (9.77 ± 1.19 mm and 6.63 ± 0.8 mm for the right and left kidneys, respectively (P < 0.001). CONCLUSION: The average size of both kidneys determined in axial images was smaller than the actual size. The estimation of kidney size in axial images is not reliable, and to obtain the actual size, it is required to have the coronal and sagittal cuts with proper quality, which could be achieved by multi-slice method.
format Online
Article
Text
id pubmed-4333429
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-43334292015-02-23 The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length Karami, Mehdi Rahimi, Farshad Tajadini, Mohammadhasan Adv Biomed Res Original Article BACKGROUND: Increased size of kidney is the main symptom of pyelonephritis and renal ischemia in children. Ultrasound and computed tomography (CT) scan methods are the imaging methods for evaluating the urogenital system. The aim of this study is to compare the kidney length obtained from spiral CT scan with the true length obtained from multi-slice CT. MATERIALS AND METHODS: From 100 patients 200 kidneys were examined in Alzahra Hospital in 2012. Multi-slice CT was used to obtain coronal and sagittal cuts to find the length of kidneys. RESULTS: The mean values of true size of axial sections of the right and left kidneys were 108.37 ± 12.3 mm and 109.74 ± 13.6 mm, respectively. The mean difference of axial sections’ lengths in the right and left kidneys was 1.37 ± 1.22 mm. The mean values of length in the spiral CT scan of the right and left kidneys were 98.61 ± 15.8 mm and 103.11 ± 15.9 mm, respectively. The difference in the estimated size by multi-slice CT scan in oblique and axial images was significant (9.77 ± 1.19 mm and 6.63 ± 0.8 mm for the right and left kidneys, respectively (P < 0.001). CONCLUSION: The average size of both kidneys determined in axial images was smaller than the actual size. The estimation of kidney size in axial images is not reliable, and to obtain the actual size, it is required to have the coronal and sagittal cuts with proper quality, which could be achieved by multi-slice method. Medknow Publications & Media Pvt Ltd 2015-01-30 /pmc/articles/PMC4333429/ /pubmed/25709984 http://dx.doi.org/10.4103/2277-9175.149850 Text en Copyright: © 2015 Karami. http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Original Article
Karami, Mehdi
Rahimi, Farshad
Tajadini, Mohammadhasan
The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length
title The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length
title_full The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length
title_fullStr The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length
title_full_unstemmed The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length
title_short The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length
title_sort evaluation and comparison of kidney length obtained from axial cuts in spiral ct scan with its true length
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4333429/
https://www.ncbi.nlm.nih.gov/pubmed/25709984
http://dx.doi.org/10.4103/2277-9175.149850
work_keys_str_mv AT karamimehdi theevaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength
AT rahimifarshad theevaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength
AT tajadinimohammadhasan theevaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength
AT karamimehdi evaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength
AT rahimifarshad evaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength
AT tajadinimohammadhasan evaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength