Cargando…
The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length
BACKGROUND: Increased size of kidney is the main symptom of pyelonephritis and renal ischemia in children. Ultrasound and computed tomography (CT) scan methods are the imaging methods for evaluating the urogenital system. The aim of this study is to compare the kidney length obtained from spiral CT...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4333429/ https://www.ncbi.nlm.nih.gov/pubmed/25709984 http://dx.doi.org/10.4103/2277-9175.149850 |
_version_ | 1782358041032654848 |
---|---|
author | Karami, Mehdi Rahimi, Farshad Tajadini, Mohammadhasan |
author_facet | Karami, Mehdi Rahimi, Farshad Tajadini, Mohammadhasan |
author_sort | Karami, Mehdi |
collection | PubMed |
description | BACKGROUND: Increased size of kidney is the main symptom of pyelonephritis and renal ischemia in children. Ultrasound and computed tomography (CT) scan methods are the imaging methods for evaluating the urogenital system. The aim of this study is to compare the kidney length obtained from spiral CT scan with the true length obtained from multi-slice CT. MATERIALS AND METHODS: From 100 patients 200 kidneys were examined in Alzahra Hospital in 2012. Multi-slice CT was used to obtain coronal and sagittal cuts to find the length of kidneys. RESULTS: The mean values of true size of axial sections of the right and left kidneys were 108.37 ± 12.3 mm and 109.74 ± 13.6 mm, respectively. The mean difference of axial sections’ lengths in the right and left kidneys was 1.37 ± 1.22 mm. The mean values of length in the spiral CT scan of the right and left kidneys were 98.61 ± 15.8 mm and 103.11 ± 15.9 mm, respectively. The difference in the estimated size by multi-slice CT scan in oblique and axial images was significant (9.77 ± 1.19 mm and 6.63 ± 0.8 mm for the right and left kidneys, respectively (P < 0.001). CONCLUSION: The average size of both kidneys determined in axial images was smaller than the actual size. The estimation of kidney size in axial images is not reliable, and to obtain the actual size, it is required to have the coronal and sagittal cuts with proper quality, which could be achieved by multi-slice method. |
format | Online Article Text |
id | pubmed-4333429 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-43334292015-02-23 The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length Karami, Mehdi Rahimi, Farshad Tajadini, Mohammadhasan Adv Biomed Res Original Article BACKGROUND: Increased size of kidney is the main symptom of pyelonephritis and renal ischemia in children. Ultrasound and computed tomography (CT) scan methods are the imaging methods for evaluating the urogenital system. The aim of this study is to compare the kidney length obtained from spiral CT scan with the true length obtained from multi-slice CT. MATERIALS AND METHODS: From 100 patients 200 kidneys were examined in Alzahra Hospital in 2012. Multi-slice CT was used to obtain coronal and sagittal cuts to find the length of kidneys. RESULTS: The mean values of true size of axial sections of the right and left kidneys were 108.37 ± 12.3 mm and 109.74 ± 13.6 mm, respectively. The mean difference of axial sections’ lengths in the right and left kidneys was 1.37 ± 1.22 mm. The mean values of length in the spiral CT scan of the right and left kidneys were 98.61 ± 15.8 mm and 103.11 ± 15.9 mm, respectively. The difference in the estimated size by multi-slice CT scan in oblique and axial images was significant (9.77 ± 1.19 mm and 6.63 ± 0.8 mm for the right and left kidneys, respectively (P < 0.001). CONCLUSION: The average size of both kidneys determined in axial images was smaller than the actual size. The estimation of kidney size in axial images is not reliable, and to obtain the actual size, it is required to have the coronal and sagittal cuts with proper quality, which could be achieved by multi-slice method. Medknow Publications & Media Pvt Ltd 2015-01-30 /pmc/articles/PMC4333429/ /pubmed/25709984 http://dx.doi.org/10.4103/2277-9175.149850 Text en Copyright: © 2015 Karami. http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Original Article Karami, Mehdi Rahimi, Farshad Tajadini, Mohammadhasan The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length |
title | The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length |
title_full | The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length |
title_fullStr | The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length |
title_full_unstemmed | The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length |
title_short | The evaluation and comparison of kidney length obtained from axial cuts in spiral CT scan with its true length |
title_sort | evaluation and comparison of kidney length obtained from axial cuts in spiral ct scan with its true length |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4333429/ https://www.ncbi.nlm.nih.gov/pubmed/25709984 http://dx.doi.org/10.4103/2277-9175.149850 |
work_keys_str_mv | AT karamimehdi theevaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength AT rahimifarshad theevaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength AT tajadinimohammadhasan theevaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength AT karamimehdi evaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength AT rahimifarshad evaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength AT tajadinimohammadhasan evaluationandcomparisonofkidneylengthobtainedfromaxialcutsinspiralctscanwithitstruelength |