Cargando…

Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil

This paper aims at developing and validating a convenient, rapid, and sensitive method for estimation of metamitron from soil samples.Determination andquantification was carried out by Gas Chromatography on microcapillary column with an Electron Capture Detector source. The compound was extracted fr...

Descripción completa

Detalles Bibliográficos
Autores principales: Tandon, Shishir, Kumar, Satyendra, Sand, N. K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4334928/
https://www.ncbi.nlm.nih.gov/pubmed/25733978
http://dx.doi.org/10.1155/2015/592763
_version_ 1782358253508755456
author Tandon, Shishir
Kumar, Satyendra
Sand, N. K.
author_facet Tandon, Shishir
Kumar, Satyendra
Sand, N. K.
author_sort Tandon, Shishir
collection PubMed
description This paper aims at developing and validating a convenient, rapid, and sensitive method for estimation of metamitron from soil samples.Determination andquantification was carried out by Gas Chromatography on microcapillary column with an Electron Capture Detector source. The compound was extracted from soil using methanol and cleanup by C-18 SPE. After optimization, the method was validated by evaluating the analytical curves, linearity, limits of detection, and quantification, precision (repeatability and intermediate precision), and accuracy (recovery). Recovery values ranged from 89 to 93.5% within 0.05- 2.0 µg L(−1) with average RSD 1.80%. The precision (repeatability) ranged from 1.7034 to 1.9144% and intermediate precision from 1.5685 to 2.1323%. Retention time was 6.3 minutes, and minimum detectable and quantifiable limits were 0.02 ng mL(−1) and 0.05 ng g(−1), respectively. Good linearity (R (2) = 0.998) of the calibration curves was obtained over the range from 0.05 to 2.0 µg L(−1). Results indicated that the developed method is rapid and easy to perform, making it applicable for analysis in large pesticide monitoring programmes.
format Online
Article
Text
id pubmed-4334928
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-43349282015-03-02 Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil Tandon, Shishir Kumar, Satyendra Sand, N. K. Int J Anal Chem Research Article This paper aims at developing and validating a convenient, rapid, and sensitive method for estimation of metamitron from soil samples.Determination andquantification was carried out by Gas Chromatography on microcapillary column with an Electron Capture Detector source. The compound was extracted from soil using methanol and cleanup by C-18 SPE. After optimization, the method was validated by evaluating the analytical curves, linearity, limits of detection, and quantification, precision (repeatability and intermediate precision), and accuracy (recovery). Recovery values ranged from 89 to 93.5% within 0.05- 2.0 µg L(−1) with average RSD 1.80%. The precision (repeatability) ranged from 1.7034 to 1.9144% and intermediate precision from 1.5685 to 2.1323%. Retention time was 6.3 minutes, and minimum detectable and quantifiable limits were 0.02 ng mL(−1) and 0.05 ng g(−1), respectively. Good linearity (R (2) = 0.998) of the calibration curves was obtained over the range from 0.05 to 2.0 µg L(−1). Results indicated that the developed method is rapid and easy to perform, making it applicable for analysis in large pesticide monitoring programmes. Hindawi Publishing Corporation 2015 2015-02-05 /pmc/articles/PMC4334928/ /pubmed/25733978 http://dx.doi.org/10.1155/2015/592763 Text en Copyright © 2015 Shishir Tandon et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Tandon, Shishir
Kumar, Satyendra
Sand, N. K.
Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil
title Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil
title_full Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil
title_fullStr Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil
title_full_unstemmed Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil
title_short Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil
title_sort development and validation of gc-ecd method for the determination of metamitron in soil
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4334928/
https://www.ncbi.nlm.nih.gov/pubmed/25733978
http://dx.doi.org/10.1155/2015/592763
work_keys_str_mv AT tandonshishir developmentandvalidationofgcecdmethodforthedeterminationofmetamitroninsoil
AT kumarsatyendra developmentandvalidationofgcecdmethodforthedeterminationofmetamitroninsoil
AT sandnk developmentandvalidationofgcecdmethodforthedeterminationofmetamitroninsoil