Cargando…

Optimal site for ultrasound-guided venous catheterisation in paediatric patients: an observational study to investigate predictors for catheterisation success and a randomised controlled study to determine the most successful site

INTRODUCTION: Venous catheterisation in paediatric patients can be technically challenging. We examined factors affecting catheterisation of invisible and impalpable peripheral veins in children and evaluated the best site for ultrasound-guided catheterisation. METHODS: Systolic pressure, age, sex,...

Descripción completa

Detalles Bibliográficos
Autores principales: Takeshita, Jun, Nakayama, Yoshinobu, Nakajima, Yasufumi, Sessler, Daniel I, Ogawa, Satoru, Sawa, Teiji, Mizobe, Toshiki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4335777/
https://www.ncbi.nlm.nih.gov/pubmed/25600063
http://dx.doi.org/10.1186/s13054-014-0733-4
_version_ 1782358395143061504
author Takeshita, Jun
Nakayama, Yoshinobu
Nakajima, Yasufumi
Sessler, Daniel I
Ogawa, Satoru
Sawa, Teiji
Mizobe, Toshiki
author_facet Takeshita, Jun
Nakayama, Yoshinobu
Nakajima, Yasufumi
Sessler, Daniel I
Ogawa, Satoru
Sawa, Teiji
Mizobe, Toshiki
author_sort Takeshita, Jun
collection PubMed
description INTRODUCTION: Venous catheterisation in paediatric patients can be technically challenging. We examined factors affecting catheterisation of invisible and impalpable peripheral veins in children and evaluated the best site for ultrasound-guided catheterisation. METHODS: Systolic pressure, age, sex, and American Society of Anaesthesiologists (ASA) physical status were determined in 96 children weighing less than 20 kg. Vein diameter and subcutaneous depth were measured with ultrasound. Logistic regression was used to evaluate the contribution of these factors to cannulation success with (n = 65) or without (n = 31) ultrasound guidance. Thereafter, we randomly assigned 196 patients for venous catheter insertion in the dorsal veins of the hand, the cephalic vein in the forearm, or the great saphenous vein. Success rates and vein diameters were evaluated by using Dunn tests; insertion time was evaluated by using Kaplan-Meier cumulative incidence analysis. RESULTS: Independent predictors of catheterisation were ultrasound guidance (odds ratio (OR) = 7.3, 95% confidence interval (CI) 2.0 to 26.0, P = 0.002), vein diameter (OR = 1.5 per 0.1 mm increase in diameter, 95% CI 1.1 to 2.0, P = 0.007), and ASA physical status (OR = 0.4 per status 1 increase, 95% CI 0.2 to 0.9, P = 0.03). Cephalic veins were significantly larger (cephalic diameter 1.8 mm, P = 0.001 versus saphenous 1.5 mm, P <0.001 versus dorsal 1.5 mm). Catheterisation success rates were significantly better at the cephalic vein than either the dorsal hand or saphenous vein (cephalic 95%, 95% CI 89% to 100%, P <0.001 versus dorsal 69%, 95% CI 56% to 82%, P = 0.03 versus saphenous 75%, 95% CI 64% to 86%). CONCLUSIONS: The cephalic vein in the proximal forearm appears to be the most appropriate initial site for ultrasound-guided catheterisation in invisible and impalpable veins of paediatric patients. TRIAL REGISTRY NUMBER: UMIN Clinical Trials Registry as UMIN000010961. Registered on 14 June 2013.
format Online
Article
Text
id pubmed-4335777
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-43357772015-02-21 Optimal site for ultrasound-guided venous catheterisation in paediatric patients: an observational study to investigate predictors for catheterisation success and a randomised controlled study to determine the most successful site Takeshita, Jun Nakayama, Yoshinobu Nakajima, Yasufumi Sessler, Daniel I Ogawa, Satoru Sawa, Teiji Mizobe, Toshiki Crit Care Research INTRODUCTION: Venous catheterisation in paediatric patients can be technically challenging. We examined factors affecting catheterisation of invisible and impalpable peripheral veins in children and evaluated the best site for ultrasound-guided catheterisation. METHODS: Systolic pressure, age, sex, and American Society of Anaesthesiologists (ASA) physical status were determined in 96 children weighing less than 20 kg. Vein diameter and subcutaneous depth were measured with ultrasound. Logistic regression was used to evaluate the contribution of these factors to cannulation success with (n = 65) or without (n = 31) ultrasound guidance. Thereafter, we randomly assigned 196 patients for venous catheter insertion in the dorsal veins of the hand, the cephalic vein in the forearm, or the great saphenous vein. Success rates and vein diameters were evaluated by using Dunn tests; insertion time was evaluated by using Kaplan-Meier cumulative incidence analysis. RESULTS: Independent predictors of catheterisation were ultrasound guidance (odds ratio (OR) = 7.3, 95% confidence interval (CI) 2.0 to 26.0, P = 0.002), vein diameter (OR = 1.5 per 0.1 mm increase in diameter, 95% CI 1.1 to 2.0, P = 0.007), and ASA physical status (OR = 0.4 per status 1 increase, 95% CI 0.2 to 0.9, P = 0.03). Cephalic veins were significantly larger (cephalic diameter 1.8 mm, P = 0.001 versus saphenous 1.5 mm, P <0.001 versus dorsal 1.5 mm). Catheterisation success rates were significantly better at the cephalic vein than either the dorsal hand or saphenous vein (cephalic 95%, 95% CI 89% to 100%, P <0.001 versus dorsal 69%, 95% CI 56% to 82%, P = 0.03 versus saphenous 75%, 95% CI 64% to 86%). CONCLUSIONS: The cephalic vein in the proximal forearm appears to be the most appropriate initial site for ultrasound-guided catheterisation in invisible and impalpable veins of paediatric patients. TRIAL REGISTRY NUMBER: UMIN Clinical Trials Registry as UMIN000010961. Registered on 14 June 2013. BioMed Central 2015-01-20 2015 /pmc/articles/PMC4335777/ /pubmed/25600063 http://dx.doi.org/10.1186/s13054-014-0733-4 Text en © Takeshita et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Takeshita, Jun
Nakayama, Yoshinobu
Nakajima, Yasufumi
Sessler, Daniel I
Ogawa, Satoru
Sawa, Teiji
Mizobe, Toshiki
Optimal site for ultrasound-guided venous catheterisation in paediatric patients: an observational study to investigate predictors for catheterisation success and a randomised controlled study to determine the most successful site
title Optimal site for ultrasound-guided venous catheterisation in paediatric patients: an observational study to investigate predictors for catheterisation success and a randomised controlled study to determine the most successful site
title_full Optimal site for ultrasound-guided venous catheterisation in paediatric patients: an observational study to investigate predictors for catheterisation success and a randomised controlled study to determine the most successful site
title_fullStr Optimal site for ultrasound-guided venous catheterisation in paediatric patients: an observational study to investigate predictors for catheterisation success and a randomised controlled study to determine the most successful site
title_full_unstemmed Optimal site for ultrasound-guided venous catheterisation in paediatric patients: an observational study to investigate predictors for catheterisation success and a randomised controlled study to determine the most successful site
title_short Optimal site for ultrasound-guided venous catheterisation in paediatric patients: an observational study to investigate predictors for catheterisation success and a randomised controlled study to determine the most successful site
title_sort optimal site for ultrasound-guided venous catheterisation in paediatric patients: an observational study to investigate predictors for catheterisation success and a randomised controlled study to determine the most successful site
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4335777/
https://www.ncbi.nlm.nih.gov/pubmed/25600063
http://dx.doi.org/10.1186/s13054-014-0733-4
work_keys_str_mv AT takeshitajun optimalsiteforultrasoundguidedvenouscatheterisationinpaediatricpatientsanobservationalstudytoinvestigatepredictorsforcatheterisationsuccessandarandomisedcontrolledstudytodeterminethemostsuccessfulsite
AT nakayamayoshinobu optimalsiteforultrasoundguidedvenouscatheterisationinpaediatricpatientsanobservationalstudytoinvestigatepredictorsforcatheterisationsuccessandarandomisedcontrolledstudytodeterminethemostsuccessfulsite
AT nakajimayasufumi optimalsiteforultrasoundguidedvenouscatheterisationinpaediatricpatientsanobservationalstudytoinvestigatepredictorsforcatheterisationsuccessandarandomisedcontrolledstudytodeterminethemostsuccessfulsite
AT sesslerdanieli optimalsiteforultrasoundguidedvenouscatheterisationinpaediatricpatientsanobservationalstudytoinvestigatepredictorsforcatheterisationsuccessandarandomisedcontrolledstudytodeterminethemostsuccessfulsite
AT ogawasatoru optimalsiteforultrasoundguidedvenouscatheterisationinpaediatricpatientsanobservationalstudytoinvestigatepredictorsforcatheterisationsuccessandarandomisedcontrolledstudytodeterminethemostsuccessfulsite
AT sawateiji optimalsiteforultrasoundguidedvenouscatheterisationinpaediatricpatientsanobservationalstudytoinvestigatepredictorsforcatheterisationsuccessandarandomisedcontrolledstudytodeterminethemostsuccessfulsite
AT mizobetoshiki optimalsiteforultrasoundguidedvenouscatheterisationinpaediatricpatientsanobservationalstudytoinvestigatepredictorsforcatheterisationsuccessandarandomisedcontrolledstudytodeterminethemostsuccessfulsite