Cargando…

Parameter evaluation and fully-automated radiosynthesis of [(11)C]harmine for imaging of MAO-A for clinical trials

The aim of the present study was the evaluation and automation of the radiosynthesis of [(11)C]harmine for clinical trials. The following parameters have been investigated: amount of base, precursor concentration, solvent, reaction temperature and time. The optimum reaction conditions were determine...

Descripción completa

Detalles Bibliográficos
Autores principales: Philippe, C., Zeilinger, M., Mitterhauser, M., Dumanic, M., Lanzenberger, R., Hacker, M., Wadsak, W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Pergamon Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4337850/
https://www.ncbi.nlm.nih.gov/pubmed/25594603
http://dx.doi.org/10.1016/j.apradiso.2015.01.002
_version_ 1782481119063572480
author Philippe, C.
Zeilinger, M.
Mitterhauser, M.
Dumanic, M.
Lanzenberger, R.
Hacker, M.
Wadsak, W.
author_facet Philippe, C.
Zeilinger, M.
Mitterhauser, M.
Dumanic, M.
Lanzenberger, R.
Hacker, M.
Wadsak, W.
author_sort Philippe, C.
collection PubMed
description The aim of the present study was the evaluation and automation of the radiosynthesis of [(11)C]harmine for clinical trials. The following parameters have been investigated: amount of base, precursor concentration, solvent, reaction temperature and time. The optimum reaction conditions were determined to be 2–3 mg/mL precursor activated with 1 eq. 5 M NaOH in DMSO, 80 °C reaction temperature and 2 min reaction time. Under these conditions 6.1±1 GBq (51.0±11% based on [(11)C]CH(3)I, corrected for decay) of [(11)C]harmine (n=72) were obtained. The specific activity was 101.32±28.2 GBq/µmol (at EOS). All quality control parameters were in accordance with the standards for parenteral human application. Due to its reliability and high yields, this fully-automated synthesis method can be used as routine set-up.
format Online
Article
Text
id pubmed-4337850
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Pergamon Press
record_format MEDLINE/PubMed
spelling pubmed-43378502015-03-03 Parameter evaluation and fully-automated radiosynthesis of [(11)C]harmine for imaging of MAO-A for clinical trials Philippe, C. Zeilinger, M. Mitterhauser, M. Dumanic, M. Lanzenberger, R. Hacker, M. Wadsak, W. Appl Radiat Isot Article The aim of the present study was the evaluation and automation of the radiosynthesis of [(11)C]harmine for clinical trials. The following parameters have been investigated: amount of base, precursor concentration, solvent, reaction temperature and time. The optimum reaction conditions were determined to be 2–3 mg/mL precursor activated with 1 eq. 5 M NaOH in DMSO, 80 °C reaction temperature and 2 min reaction time. Under these conditions 6.1±1 GBq (51.0±11% based on [(11)C]CH(3)I, corrected for decay) of [(11)C]harmine (n=72) were obtained. The specific activity was 101.32±28.2 GBq/µmol (at EOS). All quality control parameters were in accordance with the standards for parenteral human application. Due to its reliability and high yields, this fully-automated synthesis method can be used as routine set-up. Pergamon Press 2015-03 /pmc/articles/PMC4337850/ /pubmed/25594603 http://dx.doi.org/10.1016/j.apradiso.2015.01.002 Text en © 2015 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Philippe, C.
Zeilinger, M.
Mitterhauser, M.
Dumanic, M.
Lanzenberger, R.
Hacker, M.
Wadsak, W.
Parameter evaluation and fully-automated radiosynthesis of [(11)C]harmine for imaging of MAO-A for clinical trials
title Parameter evaluation and fully-automated radiosynthesis of [(11)C]harmine for imaging of MAO-A for clinical trials
title_full Parameter evaluation and fully-automated radiosynthesis of [(11)C]harmine for imaging of MAO-A for clinical trials
title_fullStr Parameter evaluation and fully-automated radiosynthesis of [(11)C]harmine for imaging of MAO-A for clinical trials
title_full_unstemmed Parameter evaluation and fully-automated radiosynthesis of [(11)C]harmine for imaging of MAO-A for clinical trials
title_short Parameter evaluation and fully-automated radiosynthesis of [(11)C]harmine for imaging of MAO-A for clinical trials
title_sort parameter evaluation and fully-automated radiosynthesis of [(11)c]harmine for imaging of mao-a for clinical trials
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4337850/
https://www.ncbi.nlm.nih.gov/pubmed/25594603
http://dx.doi.org/10.1016/j.apradiso.2015.01.002
work_keys_str_mv AT philippec parameterevaluationandfullyautomatedradiosynthesisof11charmineforimagingofmaoaforclinicaltrials
AT zeilingerm parameterevaluationandfullyautomatedradiosynthesisof11charmineforimagingofmaoaforclinicaltrials
AT mitterhauserm parameterevaluationandfullyautomatedradiosynthesisof11charmineforimagingofmaoaforclinicaltrials
AT dumanicm parameterevaluationandfullyautomatedradiosynthesisof11charmineforimagingofmaoaforclinicaltrials
AT lanzenbergerr parameterevaluationandfullyautomatedradiosynthesisof11charmineforimagingofmaoaforclinicaltrials
AT hackerm parameterevaluationandfullyautomatedradiosynthesisof11charmineforimagingofmaoaforclinicaltrials
AT wadsakw parameterevaluationandfullyautomatedradiosynthesisof11charmineforimagingofmaoaforclinicaltrials