Cargando…

Influence of shape and finishing on the corrosion of palladium-based dental alloys

PURPOSE: The purpose of this study was to evaluate the effects of the surface treatment and shape of the dental alloy on the composition of the prosthetic work and its metallic ion release in a corrosive medium after casting. MATERIALS AND METHODS: Orion Argos (Pd-Ag) and Orion Vesta (Pd-Cu) were us...

Descripción completa

Detalles Bibliográficos
Autores principales: Milheiro, Ana, Muris, Joris, Kleverlaan, Cornelis J., Feilzer, Albert J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4341188/
https://www.ncbi.nlm.nih.gov/pubmed/25722839
http://dx.doi.org/10.4047/jap.2015.7.1.56
_version_ 1782359139455860736
author Milheiro, Ana
Muris, Joris
Kleverlaan, Cornelis J.
Feilzer, Albert J.
author_facet Milheiro, Ana
Muris, Joris
Kleverlaan, Cornelis J.
Feilzer, Albert J.
author_sort Milheiro, Ana
collection PubMed
description PURPOSE: The purpose of this study was to evaluate the effects of the surface treatment and shape of the dental alloy on the composition of the prosthetic work and its metallic ion release in a corrosive medium after casting. MATERIALS AND METHODS: Orion Argos (Pd-Ag) and Orion Vesta (Pd-Cu) were used to cast two crowns and two disks. One of each was polished while the other was not. Two as-received alloys were also studied making a total of 5 specimens per alloy type. The specimens were submersed for 7 days in a lactic acid/sodium chloride solution (ISO standard 10271) and evaluated for surface structure characterization using SEM/EDAX. The solutions were quantitatively analysed for the presence of metal ions using ICP-MS and the results were statistically analysed with one-way ANOVA and a Tukey post-hoc test. RESULTS: Palladium is released from all specimens studied (range 0.06-7.08 µg·cm(-2)·week(-1)), with the Pd-Cu alloy releasing the highest amounts. For both types of alloys, ion release of both disk and crown pairs were statistically different from the as-received alloy except for the Pd-Ag polished crown (P>.05). For both alloy type, disk-shaped pairs and unpolished specimens released the highest amounts of Pd ions (range 0.34-7.08 µg·cm(-2)·week(-1)). Interestingly, in solutions submerged with cast alloys trace amounts of unexpected elements were measured. CONCLUSION: Shape and surface treatment influence ion release from dental alloys; polishing is a determinant factor. The release rate of cast and polished Pd alloys is between 0.06-0.69 µg·cm(-2)·week(-1), which is close to or exceeding the EU Nickel Directive 94/27/EC compensated for the molecular mass of Pd (0.4 µg·cm(-2)·week(-1)). The composition of the alloy does not represent the element release, therefore we recommend manufacturers to report element release after ISO standard corrosion tests beside the original composition.
format Online
Article
Text
id pubmed-4341188
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-43411882015-02-26 Influence of shape and finishing on the corrosion of palladium-based dental alloys Milheiro, Ana Muris, Joris Kleverlaan, Cornelis J. Feilzer, Albert J. J Adv Prosthodont Original Article PURPOSE: The purpose of this study was to evaluate the effects of the surface treatment and shape of the dental alloy on the composition of the prosthetic work and its metallic ion release in a corrosive medium after casting. MATERIALS AND METHODS: Orion Argos (Pd-Ag) and Orion Vesta (Pd-Cu) were used to cast two crowns and two disks. One of each was polished while the other was not. Two as-received alloys were also studied making a total of 5 specimens per alloy type. The specimens were submersed for 7 days in a lactic acid/sodium chloride solution (ISO standard 10271) and evaluated for surface structure characterization using SEM/EDAX. The solutions were quantitatively analysed for the presence of metal ions using ICP-MS and the results were statistically analysed with one-way ANOVA and a Tukey post-hoc test. RESULTS: Palladium is released from all specimens studied (range 0.06-7.08 µg·cm(-2)·week(-1)), with the Pd-Cu alloy releasing the highest amounts. For both types of alloys, ion release of both disk and crown pairs were statistically different from the as-received alloy except for the Pd-Ag polished crown (P>.05). For both alloy type, disk-shaped pairs and unpolished specimens released the highest amounts of Pd ions (range 0.34-7.08 µg·cm(-2)·week(-1)). Interestingly, in solutions submerged with cast alloys trace amounts of unexpected elements were measured. CONCLUSION: Shape and surface treatment influence ion release from dental alloys; polishing is a determinant factor. The release rate of cast and polished Pd alloys is between 0.06-0.69 µg·cm(-2)·week(-1), which is close to or exceeding the EU Nickel Directive 94/27/EC compensated for the molecular mass of Pd (0.4 µg·cm(-2)·week(-1)). The composition of the alloy does not represent the element release, therefore we recommend manufacturers to report element release after ISO standard corrosion tests beside the original composition. The Korean Academy of Prosthodontics 2015-02 2015-02-17 /pmc/articles/PMC4341188/ /pubmed/25722839 http://dx.doi.org/10.4047/jap.2015.7.1.56 Text en © 2015 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Milheiro, Ana
Muris, Joris
Kleverlaan, Cornelis J.
Feilzer, Albert J.
Influence of shape and finishing on the corrosion of palladium-based dental alloys
title Influence of shape and finishing on the corrosion of palladium-based dental alloys
title_full Influence of shape and finishing on the corrosion of palladium-based dental alloys
title_fullStr Influence of shape and finishing on the corrosion of palladium-based dental alloys
title_full_unstemmed Influence of shape and finishing on the corrosion of palladium-based dental alloys
title_short Influence of shape and finishing on the corrosion of palladium-based dental alloys
title_sort influence of shape and finishing on the corrosion of palladium-based dental alloys
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4341188/
https://www.ncbi.nlm.nih.gov/pubmed/25722839
http://dx.doi.org/10.4047/jap.2015.7.1.56
work_keys_str_mv AT milheiroana influenceofshapeandfinishingonthecorrosionofpalladiumbaseddentalalloys
AT murisjoris influenceofshapeandfinishingonthecorrosionofpalladiumbaseddentalalloys
AT kleverlaancornelisj influenceofshapeandfinishingonthecorrosionofpalladiumbaseddentalalloys
AT feilzeralbertj influenceofshapeandfinishingonthecorrosionofpalladiumbaseddentalalloys