Cargando…

Bone cement grafting increases implant primary stability in circumferential cortical bone defects

PURPOSE: Implant beds with an insufficient amount of cortical bone or a loss of cortical bone can result in the initial instability of a dental implant. Thus, the objective of this study was to evaluate the effect of bone cement grafting on implant initial stability in areas with insufficient cortic...

Descripción completa

Detalles Bibliográficos
Autores principales: Shin, Seung-Yun, Shin, Seung-Il, Kye, Seung-Beom, Chang, Seok-Woo, Hong, Jongrak, Paeng, Jun-Young, Yang, Seung-Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Periodontology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4341205/
https://www.ncbi.nlm.nih.gov/pubmed/25722924
http://dx.doi.org/10.5051/jpis.2015.45.1.30
_version_ 1782359143439400960
author Shin, Seung-Yun
Shin, Seung-Il
Kye, Seung-Beom
Chang, Seok-Woo
Hong, Jongrak
Paeng, Jun-Young
Yang, Seung-Min
author_facet Shin, Seung-Yun
Shin, Seung-Il
Kye, Seung-Beom
Chang, Seok-Woo
Hong, Jongrak
Paeng, Jun-Young
Yang, Seung-Min
author_sort Shin, Seung-Yun
collection PubMed
description PURPOSE: Implant beds with an insufficient amount of cortical bone or a loss of cortical bone can result in the initial instability of a dental implant. Thus, the objective of this study was to evaluate the effect of bone cement grafting on implant initial stability in areas with insufficient cortical bone. METHODS: Two different circumferential defect depths (2.5 mm and 5 mm) and a control (no defect) were prepared in six bovine rib bones. Fourteen implants of the same type and size (4 mm×10 mm) were placed in each group. The thickness of the cortical bone was measured for each defect. After the implant stability quotient (ISQ) values were measured three times in four different directions, bone cement was grafted to increase the primary stability of the otherwise unstable implant. After grafting, the ISQ values were measured again. RESULTS: As defect depth increased, the ISQ value decreased. In the controls, the ISQ value was 85.45±3.36 (mean±standard deviation). In circumferential 2.5-mm and 5-mm defect groups, the ISQ values were 69.42±7.06 and 57.43±6.87, respectively, before grafting. These three values were significantly different (P<0.001). After grafting the bone cement, the ISQ values significantly increased to 73.72±8.00 and 67.88±10.09 in the 2.5-mm and 5.0-mm defect groups, respectively (P<0.05 and P<0.001). The ISQ value increased to more than double that before grafting in the circumferential 5-mm defect group. The ISQ values did not significantly differ when measured in any of the four directions. CONCLUSIONS: The use of bone cement remarkably increased the stability of the implant that otherwise had an insufficient level of stability at placement, which was caused by insufficient cortical bone volume. GRAPHICAL ABSTRACT: [Image: see text]
format Online
Article
Text
id pubmed-4341205
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Korean Academy of Periodontology
record_format MEDLINE/PubMed
spelling pubmed-43412052015-02-26 Bone cement grafting increases implant primary stability in circumferential cortical bone defects Shin, Seung-Yun Shin, Seung-Il Kye, Seung-Beom Chang, Seok-Woo Hong, Jongrak Paeng, Jun-Young Yang, Seung-Min J Periodontal Implant Sci Research Article PURPOSE: Implant beds with an insufficient amount of cortical bone or a loss of cortical bone can result in the initial instability of a dental implant. Thus, the objective of this study was to evaluate the effect of bone cement grafting on implant initial stability in areas with insufficient cortical bone. METHODS: Two different circumferential defect depths (2.5 mm and 5 mm) and a control (no defect) were prepared in six bovine rib bones. Fourteen implants of the same type and size (4 mm×10 mm) were placed in each group. The thickness of the cortical bone was measured for each defect. After the implant stability quotient (ISQ) values were measured three times in four different directions, bone cement was grafted to increase the primary stability of the otherwise unstable implant. After grafting, the ISQ values were measured again. RESULTS: As defect depth increased, the ISQ value decreased. In the controls, the ISQ value was 85.45±3.36 (mean±standard deviation). In circumferential 2.5-mm and 5-mm defect groups, the ISQ values were 69.42±7.06 and 57.43±6.87, respectively, before grafting. These three values were significantly different (P<0.001). After grafting the bone cement, the ISQ values significantly increased to 73.72±8.00 and 67.88±10.09 in the 2.5-mm and 5.0-mm defect groups, respectively (P<0.05 and P<0.001). The ISQ value increased to more than double that before grafting in the circumferential 5-mm defect group. The ISQ values did not significantly differ when measured in any of the four directions. CONCLUSIONS: The use of bone cement remarkably increased the stability of the implant that otherwise had an insufficient level of stability at placement, which was caused by insufficient cortical bone volume. GRAPHICAL ABSTRACT: [Image: see text] Korean Academy of Periodontology 2015-02 2015-02-25 /pmc/articles/PMC4341205/ /pubmed/25722924 http://dx.doi.org/10.5051/jpis.2015.45.1.30 Text en Copyright © 2015 Korean Academy of Periodontology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/).
spellingShingle Research Article
Shin, Seung-Yun
Shin, Seung-Il
Kye, Seung-Beom
Chang, Seok-Woo
Hong, Jongrak
Paeng, Jun-Young
Yang, Seung-Min
Bone cement grafting increases implant primary stability in circumferential cortical bone defects
title Bone cement grafting increases implant primary stability in circumferential cortical bone defects
title_full Bone cement grafting increases implant primary stability in circumferential cortical bone defects
title_fullStr Bone cement grafting increases implant primary stability in circumferential cortical bone defects
title_full_unstemmed Bone cement grafting increases implant primary stability in circumferential cortical bone defects
title_short Bone cement grafting increases implant primary stability in circumferential cortical bone defects
title_sort bone cement grafting increases implant primary stability in circumferential cortical bone defects
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4341205/
https://www.ncbi.nlm.nih.gov/pubmed/25722924
http://dx.doi.org/10.5051/jpis.2015.45.1.30
work_keys_str_mv AT shinseungyun bonecementgraftingincreasesimplantprimarystabilityincircumferentialcorticalbonedefects
AT shinseungil bonecementgraftingincreasesimplantprimarystabilityincircumferentialcorticalbonedefects
AT kyeseungbeom bonecementgraftingincreasesimplantprimarystabilityincircumferentialcorticalbonedefects
AT changseokwoo bonecementgraftingincreasesimplantprimarystabilityincircumferentialcorticalbonedefects
AT hongjongrak bonecementgraftingincreasesimplantprimarystabilityincircumferentialcorticalbonedefects
AT paengjunyoung bonecementgraftingincreasesimplantprimarystabilityincircumferentialcorticalbonedefects
AT yangseungmin bonecementgraftingincreasesimplantprimarystabilityincircumferentialcorticalbonedefects