Cargando…

Novel algorithm for a smartphone-based 6-minute walk test application: algorithm, application development, and evaluation

BACKGROUND: The 6-minute walk test (6MWT: the maximum distance walked in 6 minutes) is used by rehabilitation professionals as a measure of exercise capacity. Today’s smartphones contain hardware that can be used for wearable sensor applications and mobile data analysis. A smartphone application can...

Descripción completa

Detalles Bibliográficos
Autores principales: Capela, Nicole A, Lemaire, Edward D, Baddour, Natalie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4343050/
https://www.ncbi.nlm.nih.gov/pubmed/25889112
http://dx.doi.org/10.1186/s12984-015-0013-9
Descripción
Sumario:BACKGROUND: The 6-minute walk test (6MWT: the maximum distance walked in 6 minutes) is used by rehabilitation professionals as a measure of exercise capacity. Today’s smartphones contain hardware that can be used for wearable sensor applications and mobile data analysis. A smartphone application can run the 6MWT and provide typically unavailable biomechanical information about how the person moves during the test. METHODS: A new algorithm for a calibration-free 6MWT smartphone application was developed that uses the test’s inherent conditions and smartphone accelerometer-gyroscope data to report the total distance walked, step timing, gait symmetry, and walking changes over time. This information is not available with a standard 6MWT and could help with clinical decision-making. The 6MWT application was evaluated with 15 able-bodied participants. A BlackBerry Z10 smartphone was worn on a belt at the mid lower back. Audio from the phone instructed the person to start and stop walking. Digital video was independently recorded during the trial as a gold-standard comparator. RESULTS: The average difference between smartphone and gold standard foot strike timing was 0.014 ± 0.015 s. The total distance calculated by the application was within 1 m of the measured distance for all but one participant, which was more accurate than other smartphone-based studies. CONCLUSIONS: These results demonstrated that clinically relevant 6MWT results can be achieved with typical smartphone hardware and a novel algorithm. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12984-015-0013-9) contains supplementary material, which is available to authorized users.