Cargando…

Spatial and Temporal Variations in Indoor Environmental Conditions, Human Occupancy, and Operational Characteristics in a New Hospital Building

The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational par...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramos, Tiffanie, Dedesko, Sandra, Siegel, Jeffrey A., Gilbert, Jack A., Stephens, Brent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4346405/
https://www.ncbi.nlm.nih.gov/pubmed/25729898
http://dx.doi.org/10.1371/journal.pone.0118207
_version_ 1782359707465285632
author Ramos, Tiffanie
Dedesko, Sandra
Siegel, Jeffrey A.
Gilbert, Jack A.
Stephens, Brent
author_facet Ramos, Tiffanie
Dedesko, Sandra
Siegel, Jeffrey A.
Gilbert, Jack A.
Stephens, Brent
author_sort Ramos, Tiffanie
collection PubMed
description The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO(2) concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ∼8×10(6) data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.
format Online
Article
Text
id pubmed-4346405
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-43464052015-03-17 Spatial and Temporal Variations in Indoor Environmental Conditions, Human Occupancy, and Operational Characteristics in a New Hospital Building Ramos, Tiffanie Dedesko, Sandra Siegel, Jeffrey A. Gilbert, Jack A. Stephens, Brent PLoS One Research Article The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO(2) concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ∼8×10(6) data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections. Public Library of Science 2015-03-02 /pmc/articles/PMC4346405/ /pubmed/25729898 http://dx.doi.org/10.1371/journal.pone.0118207 Text en © 2015 Ramos et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Ramos, Tiffanie
Dedesko, Sandra
Siegel, Jeffrey A.
Gilbert, Jack A.
Stephens, Brent
Spatial and Temporal Variations in Indoor Environmental Conditions, Human Occupancy, and Operational Characteristics in a New Hospital Building
title Spatial and Temporal Variations in Indoor Environmental Conditions, Human Occupancy, and Operational Characteristics in a New Hospital Building
title_full Spatial and Temporal Variations in Indoor Environmental Conditions, Human Occupancy, and Operational Characteristics in a New Hospital Building
title_fullStr Spatial and Temporal Variations in Indoor Environmental Conditions, Human Occupancy, and Operational Characteristics in a New Hospital Building
title_full_unstemmed Spatial and Temporal Variations in Indoor Environmental Conditions, Human Occupancy, and Operational Characteristics in a New Hospital Building
title_short Spatial and Temporal Variations in Indoor Environmental Conditions, Human Occupancy, and Operational Characteristics in a New Hospital Building
title_sort spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4346405/
https://www.ncbi.nlm.nih.gov/pubmed/25729898
http://dx.doi.org/10.1371/journal.pone.0118207
work_keys_str_mv AT ramostiffanie spatialandtemporalvariationsinindoorenvironmentalconditionshumanoccupancyandoperationalcharacteristicsinanewhospitalbuilding
AT dedeskosandra spatialandtemporalvariationsinindoorenvironmentalconditionshumanoccupancyandoperationalcharacteristicsinanewhospitalbuilding
AT siegeljeffreya spatialandtemporalvariationsinindoorenvironmentalconditionshumanoccupancyandoperationalcharacteristicsinanewhospitalbuilding
AT gilbertjacka spatialandtemporalvariationsinindoorenvironmentalconditionshumanoccupancyandoperationalcharacteristicsinanewhospitalbuilding
AT stephensbrent spatialandtemporalvariationsinindoorenvironmentalconditionshumanoccupancyandoperationalcharacteristicsinanewhospitalbuilding