Cargando…
Effects of MR Parameter Changes on the Quantification of Diffusion Anisotropy and Apparent Diffusion Coefficient in Diffusion Tensor Imaging: Evaluation Using a Diffusional Anisotropic Phantom
OBJECTIVE: To validate the usefulness of a diffusional anisotropic capillary array phantom and to investigate the effects of diffusion tensor imaging (DTI) parameter changes on diffusion fractional anisotropy (FA) and apparent diffusion coefficient (ADC) using the phantom. MATERIALS AND METHODS: Dif...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4347265/ https://www.ncbi.nlm.nih.gov/pubmed/25741191 http://dx.doi.org/10.3348/kjr.2015.16.2.297 |
_version_ | 1782359794885066752 |
---|---|
author | Kim, Sang Joon Choi, Choong Gon Kim, Jeong Kon Yun, Sung-Cheol Jahng, Geon-Ho Jeong, Ha-Kyu Kim, Eun Ju |
author_facet | Kim, Sang Joon Choi, Choong Gon Kim, Jeong Kon Yun, Sung-Cheol Jahng, Geon-Ho Jeong, Ha-Kyu Kim, Eun Ju |
author_sort | Kim, Sang Joon |
collection | PubMed |
description | OBJECTIVE: To validate the usefulness of a diffusional anisotropic capillary array phantom and to investigate the effects of diffusion tensor imaging (DTI) parameter changes on diffusion fractional anisotropy (FA) and apparent diffusion coefficient (ADC) using the phantom. MATERIALS AND METHODS: Diffusion tensor imaging of a capillary array phantom was performed with imaging parameter changes, including voxel size, number of sensitivity encoding (SENSE) factor, echo time (TE), number of signal acquisitions, b-value, and number of diffusion gradient directions (NDGD), one-at-a-time in a stepwise-incremental fashion. We repeated the entire series of DTI scans thrice. The coefficients of variation (CoV) were evaluated for FA and ADC, and the correlation between each MR imaging parameter and the corresponding FA and ADC was evaluated using Spearman's correlation analysis. RESULTS: The capillary array phantom CoVs of FA and ADC were 7.1% and 2.4%, respectively. There were significant correlations between FA and SENSE factor, TE, b-value, and NDGD, as well as significant correlations between ADC and SENSE factor, TE, and b-value. CONCLUSION: A capillary array phantom enables repeated measurements of FA and ADC. Both FA and ADC can vary when certain parameters are changed during diffusion experiments. We suggest that the capillary array phantom can be used for quality control in longitudinal or multicenter clinical studies. |
format | Online Article Text |
id | pubmed-4347265 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-43472652015-03-04 Effects of MR Parameter Changes on the Quantification of Diffusion Anisotropy and Apparent Diffusion Coefficient in Diffusion Tensor Imaging: Evaluation Using a Diffusional Anisotropic Phantom Kim, Sang Joon Choi, Choong Gon Kim, Jeong Kon Yun, Sung-Cheol Jahng, Geon-Ho Jeong, Ha-Kyu Kim, Eun Ju Korean J Radiol Experimental and Others OBJECTIVE: To validate the usefulness of a diffusional anisotropic capillary array phantom and to investigate the effects of diffusion tensor imaging (DTI) parameter changes on diffusion fractional anisotropy (FA) and apparent diffusion coefficient (ADC) using the phantom. MATERIALS AND METHODS: Diffusion tensor imaging of a capillary array phantom was performed with imaging parameter changes, including voxel size, number of sensitivity encoding (SENSE) factor, echo time (TE), number of signal acquisitions, b-value, and number of diffusion gradient directions (NDGD), one-at-a-time in a stepwise-incremental fashion. We repeated the entire series of DTI scans thrice. The coefficients of variation (CoV) were evaluated for FA and ADC, and the correlation between each MR imaging parameter and the corresponding FA and ADC was evaluated using Spearman's correlation analysis. RESULTS: The capillary array phantom CoVs of FA and ADC were 7.1% and 2.4%, respectively. There were significant correlations between FA and SENSE factor, TE, b-value, and NDGD, as well as significant correlations between ADC and SENSE factor, TE, and b-value. CONCLUSION: A capillary array phantom enables repeated measurements of FA and ADC. Both FA and ADC can vary when certain parameters are changed during diffusion experiments. We suggest that the capillary array phantom can be used for quality control in longitudinal or multicenter clinical studies. The Korean Society of Radiology 2015 2015-02-27 /pmc/articles/PMC4347265/ /pubmed/25741191 http://dx.doi.org/10.3348/kjr.2015.16.2.297 Text en Copyright © 2015 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Experimental and Others Kim, Sang Joon Choi, Choong Gon Kim, Jeong Kon Yun, Sung-Cheol Jahng, Geon-Ho Jeong, Ha-Kyu Kim, Eun Ju Effects of MR Parameter Changes on the Quantification of Diffusion Anisotropy and Apparent Diffusion Coefficient in Diffusion Tensor Imaging: Evaluation Using a Diffusional Anisotropic Phantom |
title | Effects of MR Parameter Changes on the Quantification of Diffusion Anisotropy and Apparent Diffusion Coefficient in Diffusion Tensor Imaging: Evaluation Using a Diffusional Anisotropic Phantom |
title_full | Effects of MR Parameter Changes on the Quantification of Diffusion Anisotropy and Apparent Diffusion Coefficient in Diffusion Tensor Imaging: Evaluation Using a Diffusional Anisotropic Phantom |
title_fullStr | Effects of MR Parameter Changes on the Quantification of Diffusion Anisotropy and Apparent Diffusion Coefficient in Diffusion Tensor Imaging: Evaluation Using a Diffusional Anisotropic Phantom |
title_full_unstemmed | Effects of MR Parameter Changes on the Quantification of Diffusion Anisotropy and Apparent Diffusion Coefficient in Diffusion Tensor Imaging: Evaluation Using a Diffusional Anisotropic Phantom |
title_short | Effects of MR Parameter Changes on the Quantification of Diffusion Anisotropy and Apparent Diffusion Coefficient in Diffusion Tensor Imaging: Evaluation Using a Diffusional Anisotropic Phantom |
title_sort | effects of mr parameter changes on the quantification of diffusion anisotropy and apparent diffusion coefficient in diffusion tensor imaging: evaluation using a diffusional anisotropic phantom |
topic | Experimental and Others |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4347265/ https://www.ncbi.nlm.nih.gov/pubmed/25741191 http://dx.doi.org/10.3348/kjr.2015.16.2.297 |
work_keys_str_mv | AT kimsangjoon effectsofmrparameterchangesonthequantificationofdiffusionanisotropyandapparentdiffusioncoefficientindiffusiontensorimagingevaluationusingadiffusionalanisotropicphantom AT choichoonggon effectsofmrparameterchangesonthequantificationofdiffusionanisotropyandapparentdiffusioncoefficientindiffusiontensorimagingevaluationusingadiffusionalanisotropicphantom AT kimjeongkon effectsofmrparameterchangesonthequantificationofdiffusionanisotropyandapparentdiffusioncoefficientindiffusiontensorimagingevaluationusingadiffusionalanisotropicphantom AT yunsungcheol effectsofmrparameterchangesonthequantificationofdiffusionanisotropyandapparentdiffusioncoefficientindiffusiontensorimagingevaluationusingadiffusionalanisotropicphantom AT jahnggeonho effectsofmrparameterchangesonthequantificationofdiffusionanisotropyandapparentdiffusioncoefficientindiffusiontensorimagingevaluationusingadiffusionalanisotropicphantom AT jeonghakyu effectsofmrparameterchangesonthequantificationofdiffusionanisotropyandapparentdiffusioncoefficientindiffusiontensorimagingevaluationusingadiffusionalanisotropicphantom AT kimeunju effectsofmrparameterchangesonthequantificationofdiffusionanisotropyandapparentdiffusioncoefficientindiffusiontensorimagingevaluationusingadiffusionalanisotropicphantom |